Histologic and duplex comparison of the perclose and Angio-Seal percutaneous closure devices

被引:30
|
作者
Gargiulo, Nicholas J., III
Veith, Frank J.
Ohki, Takao
Scher, Lawrence A.
Berdejo, George L.
Lipsitz, Evan C.
Menegus, Mark
Greenberg, Mark
机构
[1] Albert Einstein Coll Med, Div Vasc Surg, Montefiore Med Ctr, Bronx, NY 10467 USA
[2] Albert Einstein Coll Med, Div Cardiol, Montefiore Med Ctr, Bronx, NY 10467 USA
关键词
Angio-Seal; closure devices; perclose;
D O I
10.2310/6670.2007.00004
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The intravascular and extravascular effects of percutaneous closure devices have not been well studied. We assessed the performance and healing characteristics in dogs of two devices approved by the US Food and Drug Administration. Nine adult male dogs were anesthesized prior to percutaneous access of both femoral arteries with a 6F sheath. All dogs were systemically heparinized to an activated clotting time (ACT) > 250 seconds. Duplex sonography was performed preoperatively to measure vessel diameter and flow velocity. In each dog, one of two devices (Perclose, Abbot Laboratories, Abbott Park, IL or Angio-Seal, St. Jude Medical, St. Paul, MN) was randomly deployed into one of the two femoral arteries. The other device was deployed on the opposite side. Duplex sonography was repeated immediately after deployment and 28 days later to measure changes in vessel diameter and flow velocity. At 28 days,, angiography was performed on both femoral arteries before they were removed for histologic evaluation. The time required to excise each vessel reflected the degree of scarring. Hemostasis time for the Angio-Seal device far surpassed the Perclose device (39 +/- 7 vs 0 minutes; p < .05). Vessel narrowing was observed only at 28 days after deployment of the Angio-Seal device (p < .05). Extensive extravascular scarring was observed with the Angio-Seal device, which resulted in a longer femoral artery dissection time and greater periadventitial scar thickness compared with the Perclose device (p < .05). When compared with the Perclose suture closure device, the Angio-Seal collagen plug closure device prolonged hemostasis time and produced greater vessel narrowing and periadventitial inflammation (extravascular scarring) in a canine model at 4 weeks.
引用
收藏
页码:24 / 29
页数:6
相关论文
共 50 条
  • [31] Prospective nonrandomized trial of manual compression and angio-seal and StarClose arterial closure devices in common femoral punctures
    Chaturvedi, Patanjali
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (04) : 812 - 812
  • [32] Infectious complications related to the use of the Angio-Seal hemostatic puncture closure device
    Cooper, CL
    Miller, A
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 1999, 48 (03) : 301 - 303
  • [33] Closure of the Femoral Artery After Cardiac Catheterization-A Comparison of Angio-Seal, StarClose, and Manual Compression
    Mehta, Sameer K.
    Frutkin, Andrew D.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (04) : 586 - 586
  • [34] Comparison of Exo-Seal® and Angio-Seal® for arterial puncture site closure A randomized, multicenter, single-blind trial
    Ketterle, Johannes
    Rittger, Harald
    Helmig, Inga
    Klinghammer, Lutz
    Zimmermann, Stefan
    Hohenforst-Schmidt, Wolfgang
    Brachmann, Johannes
    Nef, Holger
    Achenbach, Stephan
    Schlundt, Christian
    HERZ, 2015, 40 (05) : 809 - 816
  • [35] A Novel Method for Achievement of Vascular Closure After Misdeployment of an Angio-Seal™ Device
    Andrew J. Gunn
    Nael E. Saad
    CardioVascular and Interventional Radiology, 2016, 39 : 1222 - 1223
  • [36] Randomized comparison of Angio-seal vs. Starclose for closure of femoral artery access in coronary catheterization
    Lee, Jong-Young
    Kim, Sung Sik
    Yi, Myung-Zoon
    Kim, Sung-Hwan
    Park, Duk-Woo
    Lee, Seung-Whan
    Kim, Young-Hak
    Lee, Cheol Whan
    Hong, Myeong-Ki
    Park, Seong-Wook
    Park, Seung-Jung
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A25 - A25
  • [37] Prospective nonrandomized trial of manual compression and Angio-Seal and Starclose arterial closure devices in common femoral punctures
    Ratnam, Lakshmi A.
    Raja, Jowad
    Munneke, Graham J.
    Morgan, Robert A.
    Belli, Anna-Maria
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (02) : 182 - 188
  • [38] CLINIC EFFECT OF ANGIO-SEAL VASCULAR CLOSURE DEVICE AFTER CORONARY INTERVENTION
    Wang Jun-Yuan
    Tang Sheng-Xing
    Zhu Zheng-Cai
    Xia Chao-Hong
    Ke Yong-Sheng
    Cao Heng
    HEART, 2011, 97 : A167 - A167
  • [39] Infectious complications related to the use of the angio-seal hemostatic puncture closure device
    Eggebrecht, H
    Haude, M
    Baumgart, D
    Erbel, R
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2000, 49 (03) : 352 - 352
  • [40] Prospective Nonrandomized Trial of Manual Compression and Angio-Seal and StarClose Arterial Closure Devices in Common Femoral Punctures
    Patanjali Chaturvedi