An amperometric solid-state NO2 sensor with a solid polymer electrolyte and a reticulated vitreous carbon indicator electrode

被引:35
|
作者
Hrncírová, P [1 ]
Opekar, F [1 ]
Stulík, K [1 ]
机构
[1] Charles Univ, Dept Analyt Chem, UNESCO, Lab Environm Electrochem, Prague 12840 2, Czech Republic
关键词
nitrogen dioxide; reticulated vitreous carbon; solid-state sensor; solid polymer electrolyte;
D O I
10.1016/S0925-4005(00)00540-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Reticulated vitreous carbon (RVC) was tested as a material for the preparation of the indicator electrode in solid-state gas sensors. The test planar sensor contained a RVC indicator, a platinum auxiliary and a Pt/air reference electrode, with a solid polymer electrolyte (SPE) of 10% PVC, 3% tetrabutylammonium hexafluorophosphate (TBAHFP) and 87% of 2-nitrophenyloctyl ether (NPOE). The analyte, gaseous nitrogen dioxide in air, was monitored by reduction at - 500 mV vs. the Pt/air electrode. The reduction current was linearly dependent on the analyte concentration over the whole test range, from 0.2 to 2.2 ppm (v/v). The sensitivity of determination amounted to 277 nA/ppm, the limit of detection was 80 ppb (at a relative humidity, RH, of 54%) and 90% of the steady-state signal was attained within 19 s. The measuring sensitivity depended on the temperature, the gas flow rate and the RH with slopes of 1.04% per 1 degrees C, 32% per 1 ml/s and 0.16% per 1% RH, respectively. It has been demonstrated that RVC can successfully replace noble metals in gas solid-state sensors. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:199 / 204
页数:6
相关论文
共 50 条
  • [31] Study of amperometric diffusion solid-state electrolyte cell operating regimes
    V. P. Pirog
    A. M. Gaba
    A. K. Semchevskii
    G. M. Murzin
    Measurement Techniques, 2008, 51 : 1143 - 1146
  • [32] Dry Polymer Electrolyte Concepts for Solid-State Batteries
    Popovic, Jelena
    MACROMOLECULAR CHEMISTRY AND PHYSICS, 2022, 223 (08)
  • [33] Solid-state amperometric CH4 sensor using, LaGaO3-based electrolyte
    Bi, Zhonghe
    Matsumoto, Hiroshige
    Ishihara, Tatsumi
    SOLID STATE IONICS, 2008, 179 (27-32) : 1641 - 1644
  • [34] An Electrochemical Amperometric Ethylene Sensor with Solid Polymer Electrolyte Based on Ionic Liquid
    Kubersky, Petr
    Navratil, Jiri
    Syrovy, Tomas
    Sedlak, Petr
    Nespurek, Stanislav
    Hamacek, Ales
    SENSORS, 2021, 21 (03) : 1 - 14
  • [35] AC impedance characteristics of solid-state planar electrochemical carbon monoxide sensors with Nafion® as solid polymer electrolyte
    Mortimer, RJ
    Beech, A
    ELECTROCHIMICA ACTA, 2002, 47 (20) : 3383 - 3387
  • [36] Solid-State Electrolytes and Electrode/Electrolyte Interfaces in Rechargeable Batteries
    Chai, Simin
    He, Qiong
    Zhou, Ji
    Chang, Zhi
    Pan, Anqiang
    Zhou, Haoshen
    CHEMSUSCHEM, 2024, 17 (03)
  • [37] Solid electrolyte–electrode interface based on buffer therapy in solid-state lithium batteries
    Lei-ying Wang
    Li-fan Wang
    Rui Wang
    Rui Xu
    Chun Zhan
    Woochul Yang
    Gui-cheng Liu
    InternationalJournalofMineralsMetallurgyandMaterials, 2021, 28 (10) : 1584 - 1602
  • [38] USE OF AN INTERCALATION OXIDE AS A REFERENCE ELECTRODE IN AN ALL SOLID-STATE POLYMER ELECTROLYTE PHOTOELECTROCHEMICAL CELL
    MARSAN, B
    FAUTEUX, D
    VIJH, AK
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1987, 134 (10) : 2508 - 2510
  • [39] Flexible solid-state supercapacitors based on carbon aerogel and some electrolyte polymer gels
    T. Esawy
    M. Khairy
    A. Hany
    M. A. Mousa
    Applied Physics A, 2018, 124
  • [40] Solid-state amperometric CO2 sensor using a sodium ion conductor
    Lee, JS
    Lee, JH
    Hong, SH
    JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2004, 24 (06) : 1431 - 1434