A CR-39 based thermal neutron dosimeter

被引:3
|
作者
Ahmad, N
Matiullah
Kenawy, MA
机构
[1] Ctr Nucl Studies, Islamabad, Pakistan
[2] Ain Shams Univ, Univ Coll Girls, Dept Phys, Cairo, Egypt
关键词
CR-39; LiF films; activation foils; personal neutron dosimetry; vacuum coating unit; beta-gamma coincidence;
D O I
10.1016/S1350-4487(97)00111-X
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Both chemically and electrochemically etched CR-39 detectors are used for the detection of fast neutrons. In practical situations, fast neutrons are always accompanied by thermal neutrons. Therefore, the response of the CR-39 based dosimeter has to be extended to thermal neutrons. To do so, a radiator/converter libe LiF is introduced in front of the CR-39 detector and an optimum thickness of the LiF film is determined so that a response similar to that of the fast neutrons is achieved. Thin films of natural LiF were prepared and the response of the CR-39 detector was studied as a function of the film thickness.
引用
收藏
页码:413 / 414
页数:2
相关论文
共 50 条
  • [21] SOME ENVIRONMENTAL TRIAL RESULTS FOR A PLANAR AND ISOTROPIC CR-39 NEUTRON DOSIMETER
    JACKSON, M
    FRENCH, A
    HARVEY, JR
    WEEKS, AR
    RADIATION MEASUREMENTS, 1995, 25 (1-4) : 461 - 462
  • [22] CR-39 detector based thermal neutron flux measurements, in the photo neutron project
    Mameli, A.
    Greco, F.
    Fidanzio, A.
    Fusco, V.
    Cilla, S.
    D'Onofrio, G.
    Grimaldi, L.
    Augelli, B. G.
    Giannini, G.
    Bevilacqua, R.
    Totaro, P.
    Tommasino, L.
    Azario, L.
    Piermattei, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (16): : 3656 - 3660
  • [23] CR-39 AS A GAMMA-RAY DOSIMETER
    ASFAR, AN
    CLAY, PG
    WILLIAMS, JG
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1984, 8 (1-4): : 129 - 132
  • [24] CR-39 AS A TRACK-DETECTOR FOR A REM-EQUIVALENT PERSONNEL NEUTRON DOSIMETER
    FAERMANN, S
    EISEN, Y
    WEINGARTEN, R
    OVADIA, E
    KARPINOVITCH, Z
    SHAMAI, Y
    SCHLESINGER, T
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1981, 5 (04): : 372 - 372
  • [25] DEVELOPMENT OF A THERMAL AND FAST-NEUTRON DOSE EQUIVALENT DOSIMETER USING CR-39 DETECTOR WITH RADIATORS-CONVERTERS
    DURRANI, SA
    MATIULLAH
    RADIATION PROTECTION DOSIMETRY, 1988, 23 (1-4) : 183 - 186
  • [26] A CUBICAL FAST-NEUTRON DOSIMETER BASED ON ELECTROCHEMICALLY ETCHED CR-39 DETECTORS WITH POLYMERIC FRONT RADIATORS
    MATIULLAH
    DURRANI, SA
    RADIATION PROTECTION DOSIMETRY, 1987, 20 (1-2) : 77 - 80
  • [27] COPOLYMERS OF CR-39 FOR NEUTRON DOSIMETRY
    YANG, CS
    HUANG, SJ
    JOHNSON, JF
    HADLOCK, DE
    PARKHURST, MA
    HEALTH PHYSICS, 1986, 50 : S19 - S19
  • [28] NEUTRON SENSITIVITY OF CR-39 SSNTD
    BIRKHOLZ, W
    WINKLER, C
    BAUMBACH, H
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1991, 19 (1-4): : 453 - 456
  • [29] MAKROFOL AND CR-39 RECOIL TRACK ETCH DETECTORS AS A SUPPLEMENT OF A UNIVERSAL ALBEDO NEUTRON DOSIMETER
    PIESCH, E
    JASIAK, J
    URBAN, M
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1984, 8 (1-4): : 323 - 326
  • [30] FLAT ANGULAR RESPONSE OF A FAST-NEUTRON DOSIMETER USING CYLINDRICAL SHAPED CR-39
    ALNAJJAR, SAR
    PIESCH, E
    RADIATION PROTECTION DOSIMETRY, 1988, 23 (1-4) : 161 - 164