In this paper, a new design of atmospheric air passive cooling system which consists of an earth-air pipe heat exchanger is proposed. The objective of this system is to cool the warm ambient air for thermal applications in hot arid areas. A 1.5 m long copper pipe with 1.5 cm inner diameter was buried under the soil contained in a galvanized steel drum. The blower and air heater were used at pipe inlet to induce warm air inside the pipe which gets cooled in earth-air pipe heat exchanger. The experiments were performed under the controlled conditions of operating parameters such as induced air temperature, flow rate and soil bulk temperature. The performance of considered heat exchanger was studied for three different soil compaction levels with distinct values of relative density, void ratio and porosity. The results showed that induced air temperature was dropped in the range between 8 and 24 degrees C across the earth-air pipe heat exchanger and the system effectiveness varied between 0.3 and 0.7 depending on the operating conditions and soil compaction. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1319 / 1327
页数:9
相关论文
共 50 条
  • [31] Numerical Investigation of Chlorinated Polyvinyl Chloride Pipe Earth Air Tunnel Heat Exchanger at Different Pipe Diameter
    Hasan, Nasim
    Sheikh, Mohd Yunus
    Bulcha, Addisu
    Adeba, Juhar
    INTERNATIONAL CONFERENCE ON APPLIED MECHANICS AND OPTIMISATION (ICAMEO-2019), 2019, 2134
  • [32] Investigation on the cooling performance of a buoyancy driven earth-air heat exchanger system and the impact on indoor thermal environment
    Long, Tianhe
    Li, Yongcai
    Li, Wuyan
    Liu, Shuli
    Lu, Jun
    Zheng, Dimeng
    Ye, Kai
    Qiao, Zhenyong
    Huang, Sheng
    APPLIED THERMAL ENGINEERING, 2022, 207
  • [33] Experimental and analytical studies of earth-air heat exchanger (EAHE) systems in India: A review
    Bisoniya, Trilok Singh
    Kumar, Anil
    Baredar, Prashant
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 19 : 238 - 246
  • [34] Structural design method, validation, and performance analysis of an earth-air heat exchanger for greenhouses
    Xiao, Jinxin
    Hu, Yixin
    Wang, Qiang
    Li, Jianming
    GEOTHERMICS, 2023, 111
  • [35] Performance Analysis of PCM Ceiling Coupling with Earth-Air Heat Exchanger for Building Cooling
    Lu, Shilei
    Liang, Bin
    Li, Xinhua
    Kong, Xiangfei
    Jia, Wei
    Wang, Lu
    MATERIALS, 2020, 13 (13) : 1 - 17
  • [36] A parametric analysis of the cooling performance of vertical earth-air heat exchanger in a subtropical climate
    Ahmed, S. F.
    Khan, M. M. K.
    Amanullah, M. T. O.
    Rasul, M. G.
    Hassan, N. M. S.
    RENEWABLE ENERGY, 2021, 172 : 350 - 367
  • [37] Evaluation of Thermal Performance of Single Pass Earth-Air Heat Exchanger in Heating Mode
    Deldan, Namgial
    Rajan, Aggarwal
    Hans, Vishavjeet S.
    Kaushal, Arun
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2017, 36 (04) : 1253 - 1261
  • [38] THERMAL PERFORMANCE OF EARTH-AIR HEAT EXCHANGER SYSTEMS FOR COOLING APPLICATIONS IN RESIDENTIAL BUILDINGS
    Ghaith, Fadi A.
    Razzaq, Habib Ur
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2018, VOL 6A, 2019,
  • [39] Parametric Study and Energy Performance of an Earth-Air Heat Exchanger for a Poultry House in Morocco
    Laknizi, Azzeddine
    Mahdaoui, Mustapha
    Anoune, Kamal
    Bakhouya, Mohamed
    Ben Abdellah, Abdelatif
    Oussous, Hamza
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2018, 8 (04): : 2047 - 2056
  • [40] Analysis on effective pipe length of earth-air heat exchanger based on annual cooling/heating capacities
    Su H.
    Wei S.
    Li Q.
    Fu H.
    Guo T.
    Li, Qian (cyqlq@mail.xhu.edu.cn), 1600, Science Press (42): : 470 - 477