A comparison of double single suture-button fixation, suture-button fixation, and screw fixation for ankle syndesmosis injury A retrospective cohort study

被引:8
|
作者
Kurtoglu, Alper [1 ]
Kochai, Alauddin [1 ]
Inanmaz, Mustafa Erkan [1 ]
Sukur, Erhan [1 ]
Keskin, Dogan [1 ]
Turker, Mehmet [1 ]
Uysal, Mustafa [1 ]
Sen, Zafer [2 ]
Daldal, Ismail [3 ]
机构
[1] Sakarya Univ, Res & Training Hosp, Adaparari, Sakarya, Turkey
[2] Univ Hlth Sci, Konya City Hosp Orthoped & Traumatol, Ankara, Turkey
[3] Lokman Hekim Akay Hosp Dept Orthopaed & Traumatol, Ankara, Turkey
关键词
ankle fracture; American Orthopaedic Foot and Ankle Society; screw fixation; suture endobutton; syndesmosis injury; DISTAL TIBIOFIBULAR SYNDESMOSIS; FRACTURES; REMOVAL; RISK;
D O I
10.1097/MD.0000000000025328
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Different methods have been used throughout the years for syndesmotic injury but there is no consensus on the ideal treatment. Some methods are expensive and some have more complications. The aim of this study is to compare single suture endobutton with double suture endobutton and screw fixation for syndesmotic injury. Sixty nine patients with syndesmotic injury with fibular fractures whom were treated with a single interosseous suture endobutton system (ZipTight(TM), Zimmer Biomet), a double interosseous suture endobutton system (ZipTight(TM), Zimmer Biomet) and 1 syndesmotic screw (TST, Istanbul, Turkey) were included in this study. Functional and radiological results from patient records between 2015 and 2018 were retrospectively evaluated. Twenty patients were treated with the double interosseous suture endobutton, 23 were treated with the single interosseous suture endobutton, and 26 were treated with traditional AO screw fixation. Three patients from the screw fixation group (11.5%) required revision surgery (P < .05). All the radiologic and clinical outcomes were statistical similar in all 3 groups. Our findings showed that the interosseous suture endobutton system is at least as safe as the screw fixation technique for treatment of syndesmosis joint injuries and can be used as an alternative to the screw method. The interosseous suture endobutton system eliminates the need for a second surgery to remove the hardware, which minimizes the probability of re-diastasis. Since our results showed no statistical difference between single and double interosseous suture endobutton systems, the less costly single endobutton system may be the better alternative.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] A 10-Year Follow-Up of Ankle Syndesmotic Injuries: Prospective Comparison of Knotless Suture-Button Fixation and Syndesmotic Screw Fixation
    Altmeppen, Jan Niklas
    Colcuc, Christian
    Balser, Christian
    Gramlich, Yves
    Klug, Alexander
    Neun, Oliver
    Manegold, Sebastian
    Hoffmann, Reinhard
    Fischer, Sebastian
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (09)
  • [22] Strength of suture-button fixation versus ligament reconstruction in syndesmotic injury: a biomechanical study
    Hong-Yun Li
    Ru-Shou Zhou
    Zi-Ying Wu
    Yutong Zhao
    Shi-Yi Chen
    Ying-Hui Hua
    International Orthopaedics, 2019, 43 : 705 - 711
  • [23] Clinical outcomes of isolated acute instability of the syndesmosis treated with arthroscopy and percutaneous suture-button fixation
    Danilo Ryuko Cândido Nishikawa
    Guilherme Honda Saito
    Adilson Sanches de Oliveira Junior
    Alberto Abussamra Moreira Mendes
    Leticia Piovesana Devito
    Marcelo Pires Prado
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 1567 - 1574
  • [24] Clinical outcomes of isolated acute instability of the syndesmosis treated with arthroscopy and percutaneous suture-button fixation
    Nishikawa, Danilo Ryuko Candido
    Saito, Guilherme Honda
    de Oliveira Junior, Adilson Sanches
    Mendes, Alberto Abussamra Moreira
    Devito, Leticia Piovesana
    Prado, Marcelo Pires
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (09) : 1567 - 1574
  • [25] Screw fixation versus suture-button fixation for the Latarjet procedure-a systematic review and meta-analysis
    Rossi, Luciano A.
    Pasqualini, Ignacio
    Frangiamore, Salvatore J.
    Anakwenze, Oke
    Dickens, Jonathan
    Klifto, Christopher
    Hurley, Eoghan
    SHOULDER & ELBOW, 2025, 17 (01) : 14 - 21
  • [26] A Systematic Review and Meta-Analysis on Treatment of Ankle Fractures With Syndesmotic Rupture: Suture-Button Fixation Versus Cortical Screw Fixation
    McKenzie, Alexandra C.
    Hesselholt, Kristian E.
    Larsen, Morten S.
    Schmal, Hagen
    JOURNAL OF FOOT & ANKLE SURGERY, 2019, 58 (05): : 946 - 953
  • [27] Suture-button Versus Screw Fixation in Adolescent Syndesmotic Injuries: Functional Outcomes and Maintenance of Reduction
    Lurie, Benjamin M.
    Paez, Conner J.
    Howitt, Shayna R.
    Pennock, Andrew T.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2021, 41 (06) : E427 - E432
  • [28] The Impact of Suture Button Removal in Syndesmosis Fixation
    Kim, Jaeyoung
    Kwon, Minsoo
    Day, Jonathan
    Seilern und Aspang, Jesse
    Shim, Jaehoon
    Cho, Jaeho
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (16)
  • [29] Comparison of a Novel Modified All-Suture Construct versus Suspensory Suture-button Fixation in a Syndesmotic Injury Model
    Baker, Hayden P.
    Muriuki, Muturi G.
    Straszewski, Andrew J.
    Johnson, Christopher
    Krishnan, Pranav
    Hynes, Kelly
    Strelzow, Jason A.
    Havey, Robert M.
    Dillman, Daryl B.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2023, 37 (03) : E104 - E110
  • [30] Augmenting Suture-Button Fixation for Maisonneuve Injuries With Fibular Shortening: Technique Tip
    Riedel, Matthew D.
    Miller, Christopher P.
    Kwon, John Y.
    FOOT & ANKLE INTERNATIONAL, 2017, 38 (10) : 1146 - 1151