Fire Protective Glass Fiber Reinforced Concrete Plates for Steel Structures under Different Types of Fire Exposure

被引:9
|
作者
Gravit, Marina [1 ]
Golub, Elena [2 ]
Klementev, Boris [3 ]
Dmitriev, Ivan [1 ]
机构
[1] Peter Great St Petersburg Polytech Univ, Civil Engn Inst, Peter Great St, 195251 St, St Petersburg 195251, Russia
[2] State Hermitage Museum, St Petersburg 190000, Russia
[3] LLC Arctic LNG 2, Dept Expertise, Moscow 117393, Russia
关键词
fire resistance; hydrocarbon fire; fire protection; computer simulation; steel structure; BEHAVIOR;
D O I
10.3390/buildings11050187
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In a situation where a fire occurs either in a tunnel with a burning vehicle carrying petroleum products, at an offshore platform, or at an oil and gas asset to be protected, such a case is commonly described using a hydrocarbon fire curve. Therefore, it is extremely important to design construction, which can maintain stability and bearing capacity both under the standard and hydrocarbon fire modes. The purpose in this work is to hold a behavior simulation of a steel structure with fireproofing ensured through lightweight concrete slabs reinforced with fiber glass as well as a validation of the outcomes by assessing the experimental findings obtained from the relevant fire tests. A fire resistance study was carried out here for steel structures with a profile ratio of 156 mm(-1) for the cases of a standard fire and of a hydrocarbon fire. A constant static load of 687 kN (70 tf) was taken for standard fire and 294 kN (30 tf) for hydrocarbon fire; the column was under vertical compression with one end resting on a hinged support and the other end rigidly fixed. The specimen design incorporated single-layer box-section cladding made of Pyro-Safe Aestuver T slabs, 40 mm thick and of a 650 kg/m(3) density, pre-cut to fit the column size. The column strength loss (R) ultimately occurred after 240 min in the standard fire case and after 180 min in the hydrocarbon fire case. As the breach in the fireproofing structural integrity (E) or the installation accuracy cannot be considered, the limit state indicators may show certain discrepancies. According to the simulation performed using SOFiSTiK software, the design fire resistance rating of the structure in a hydrocarbon fire case was 58% higher than the figure obtained by holding fire tests due to the slabs cracking during the experiment session; the discrepancy between the outcomes of the session and the simulation in a standard fire case was as much as 15%.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Structural Behavior of Concrete One-Way Slab with Mixed Reinforcement of Steel and Glass Fiber Polymer Bars under Fire Exposure
    Rasheed, Mohammed R.
    Mohammed, Shatha D.
    ENGINEERING TECHNOLOGY & APPLIED SCIENCE RESEARCH, 2024, 14 (02) : 13380 - 13387
  • [33] Modelling of reinforced concrete structures subjected to fire
    Cervenka, J.
    Surovec, J.
    Kabele, P.
    Computational Modelling of Concrete Structures, 2006, : 515 - 522
  • [34] EFFECT OF FIRE ON FRP REINFORCED CONCRETE STRUCTURES
    Zlamal, Martin
    Kucerova, Anna
    Stepanek, Par
    SUSTAINABLE BUILDING AND REFURBISHMENT FOR NEXT GENERATIONS, 2013, : 493 - 496
  • [35] Post-fire performance of steel reinforced concrete columns with different steel sections
    Hassani, Meisam
    Safi, Mohammad
    Ardakani, Reza Rasti
    Daryan, Amir Saedi
    ADVANCES IN STRUCTURAL ENGINEERING, 2021, 24 (16) : 3724 - 3738
  • [36] High temperature properties of fiber reinforced polymers and fire insulation for fire resistance modeling of strengthened concrete structures
    Kodur, V. K. R.
    Bhatt, P. P.
    Naser, M. Z.
    COMPOSITES PART B-ENGINEERING, 2019, 175
  • [37] Finite element analysis of fire resistance of steel reinforced concrete frame structures
    Wang G.
    Sun X.
    Zhang D.
    Zheng C.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (02): : 65 - 75
  • [38] Fiber-Reinforced Polymer-Strengthened/Reinforced Concrete Structures Exposed to Fire: A Review
    Maraveas, Chrysanthos
    Miamis, Konstantinos
    Vrakas, Apostolos A.
    STRUCTURAL ENGINEERING INTERNATIONAL, 2012, 22 (04) : 500 - 513
  • [39] Tests on the Steel-Concrete Bond Strength in Steel Reinforced Concrete (SRC) Columns After Fire Exposure
    Wang, Wei-Hua
    Han, Lin-Hai
    Tan, Qing-Hua
    Tao, Zhong
    FIRE TECHNOLOGY, 2017, 53 (02) : 917 - 945
  • [40] Effect of Fire Exposure on the Properties of Self-Compacting Concrete reinforced by Glass Fibers
    Aboud, Rawaa K.
    Awad, Hadeel K.
    Mohammed, Shatha D.
    ENGINEERING TECHNOLOGY & APPLIED SCIENCE RESEARCH, 2024, 14 (02) : 13369 - 13375