Association of robot-assisted techniques with the accuracy rates of pedicle screw placement: A network pooling analysis

被引:13
|
作者
Wei, Fei-Long [1 ]
Gao, Quan-You [1 ]
Heng, Wei [1 ]
Zhu, Kai-Long [1 ]
Yang, Fan [1 ]
Du, Ming-Rui [1 ]
Zhou, Cheng-Pei [1 ]
Qian, Ji-Xian [1 ]
Yan, Xiao-Dong [1 ]
机构
[1] Fourth Mil Med Univ, Tangdu Hosp, Dept Orthopaed, 569 Xinsi Rd, Xian 710038, Peoples R China
基金
中国国家自然科学基金;
关键词
Artificial intelligence; Accuracy; Safety; Cervical spinal surgery; Robot-assist; FACET JOINT VIOLATION; SPINE SURGERY; LUMBAR SPINE; INSERTION; FLUOROSCOPY; NAVIGATION; FIXATION; GUIDANCE; INSTRUMENTATION; COHORT;
D O I
10.1016/j.eclinm.2022.101421
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Traditional paired meta-analyses have yielded inconsistent results for the safety and effectiveness of robotic-assisted pedicle screw placement due to the high heterogeneity within studies. This study evaluated the clinical effectiveness and safety of robotic-assisted pedicle screw placement. Methods The Embase, PubMed, and Cochrane Library databases were searched with no language limitations from inception to Jan 4, 2022. Odds ratio (OR), mean difference (MD), and 95% confidence interval (CI) were used to report results. The main outcomes were accuracy of pedicle screw placement, proximal facet joint violation, and complications. The study protocol was published in PROSPERO (CRD42022301417). Findings 26 trials including 2046 participants evaluating robotic-assisted pedicle screw placement were included in this study. Our pooled results showed that Renaissance (OR 2.86; [95% CI 1.79 to 4.57]) and TiRobot (OR 3.10; [95% CI 2.19 to 4.40]) yielded higher rates of perfect pedicle screw insertion (Grades A) than the conventional freehand technique. Renaissance (OR 2.82; [95% CI 1.51 to 5.25]) and TiRobot (OR 4.58; [95% CI 2.65 to 7.89]) yielded higher rates of clinically acceptable pedicle screw insertion (Grades A+B). However, ROSA, SpineAssist, and Orthobot were not associated with higher perfect pedicle screw insertion and clinically acceptable pedicle screw insertion rates. Robot-assisted techniques were associated with low rates of proximal facet joint violation (OR 0.18; [95% CI 0.10 to 0.32]; I2:9.55%) and overall complications (OR 0.38; [95% CI 0.23 to 0.63]; I2:27.05%). Moreover, robot-assisted techniques were associated with lower radiation doses (MD -14.38; [95% CI -25.62 to -3.13]; I2:100.00%). Interpretation Our findings suggest that only Renaissance and TiRobot systems are associated with high accuracy rates of pedicle screw placement. Robotic-assisted techniques hold great promise in spinal surgery due to their safety and effectiveness. Copyright (C) 2022 The Authors. Published by Elsevier Ltd.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Techniques and accuracy of thoracolumbar pedicle screw placement
    Puvanesarajah, Varun
    Liauw, Jason A.
    Lo, Sheng-fu
    Lina, Ioan A.
    Witham, Timothy F.
    WORLD JOURNAL OF ORTHOPEDICS, 2014, 5 (02): : 112 - 123
  • [22] Letter: Learning Curves for Robot-Assisted Pedicle Screw Placement: Analysis of Operative Time for 234 Cases
    Smith, Zachary A.
    Muhammad, Fauziyya
    Baaj, Ali A.
    OPERATIVE NEUROSURGERY, 2024, 26 (04) : 487 - 488
  • [23] In Reply: Learning Curves for Robot-Assisted Pedicle Screw Placement: Analysis of Operative Time for 234 Cases
    Jiang, Kelly
    Weber-Levine, Carly
    Theodore, Nicholas
    OPERATIVE NEUROSURGERY, 2024, 26 (04) : 489 - 489
  • [24] Ultrasound-Based Robot-Assisted Drilling for Minimally Invasive Pedicle Screw Placement
    Li, Ruixuan
    Davoodi, Ayoob
    Timmermans, Maikel
    Van Assche, Kaat
    Taylan, Orcun
    Scheys, Lennart
    Tummers, Matthias
    Borghesan, Gianni
    Poorten, Emmanuel Vander
    IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2024, 6 (03): : 818 - 828
  • [25] Anatomical and Technical Considerations of Robot-Assisted Cervical Pedicle Screw Placement: A Cadaveric Study
    Mao, Jennifer Z.
    Soliman, Mohamed A. R.
    Karamian, Brian A.
    Khan, Asham
    Fritz, Alexander G.
    Avasthi, Naval
    DiMaria, Stephen
    Levy, Bennett R.
    O'Connor, Timothy E.
    Schroeder, Gregory
    Pollina, John
    Vaccaro, Alexander R.
    Mullin, Jeffrey P.
    GLOBAL SPINE JOURNAL, 2023, 13 (07) : 1992 - 2000
  • [26] Three-dimensional assessment of robot-assisted pedicle screw placement accuracy and instrumentation reliability based on a preplanned trajectory
    Jiang, Bowen
    Pennington, Zach
    Zhu, Alex
    Matsoukas, Stavros
    Ahmed, A. Karim
    Ehresman, Jeff
    Mahapatra, Smruti
    Cottrill, Ethan
    Sheppell, Hailey
    Manbachi, Amir
    Crawford, Neil
    Theodore, Nicholas
    JOURNAL OF NEUROSURGERY-SPINE, 2020, 33 (04) : 519 - 528
  • [27] Lateral versus prone robot-assisted percutaneous pedicle screw placement: a CT-based comparative assessment of accuracy
    Fayed, Islam
    Tai, Alexander
    Triano, Matthew J.
    Weitz, Daniel
    Sayah, Anousheh
    Voyadzis, Jean-Marc
    Sandhu, Faheem A.
    JOURNAL OF NEUROSURGERY-SPINE, 2022, 37 (01) : 112 - 120
  • [28] Accuracy of Robot-Assisted Placement of Lumbar and Sacral Pedicle Screws A Prospective Randomized Comparison to Conventional Freehand Screw Implantation
    Ringel, Florian
    Stueer, Carsten
    Reinke, Andreas
    Preuss, Alexander
    Behr, Michael
    Auer, Florian
    Stoffel, Michael
    Meyer, Bernhard
    SPINE, 2012, 37 (08) : E496 - E501
  • [29] The safety and accuracy of robot-assisted pedicle screw internal fixation for spine disease A META-ANALYSIS
    Li, W.
    Li, G.
    Chen, W.
    Cong, L.
    BONE & JOINT RESEARCH, 2020, 9 (10): : 653 - 666
  • [30] Safety and Accuracy of Robot-Assisted Cervical Screw Placement: A Systematic Review and Meta-Analysis
    Peng, Jing
    Li, Qiang
    Zhang, Xuejun
    Li, Jiaheng
    Wan, Song
    Yu, Shuangqi
    Chen, Wei
    Chen, Dong
    Ding, Fan
    WORLD NEUROSURGERY, 2024, 181 : 163 - 176