Improved Image Quality and Decreased Radiation Dose of Lower Extremity Computed Tomography Angiography Using Low-Tube-Voltage and Adaptive Iterative Reconstruction

被引:7
|
作者
Pan, Yu-Ning [1 ,2 ]
Li, Ai-Jing [3 ]
Chen, Zhao-Qian [1 ,2 ]
Ren, Da-Wei [1 ]
Zhang, Jie [1 ]
Jiang, Mao-Qing [1 ]
Huang, Qiu-Li [1 ]
机构
[1] Ningbo First Hosp, Dept Radiol, 59 Liuting Rd, Ningbo, Zhejiang, Peoples R China
[2] Ningbo Univ, Dept Med Coll, Ningbo 315211, Zhejiang, Peoples R China
[3] Ningbo 2 Hosp, Dept Radiol, Ningbo, Zhejiang, Peoples R China
关键词
lower extremity; angiography; radiation dose; image noise; iterative reconstruction; DIGITAL-SUBTRACTION-ANGIOGRAPHY; ROW CT ANGIOGRAPHY; REDUCTION; EXPOSURE; ARTERIES; DISEASE;
D O I
10.1097/RCT.0000000000000356
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective The aim of the study was to investigate the feasibility of low-tube-voltage computed tomography (CT) in combination with 3-dimensional adaptive iterative dose reduction (AIDR-3D) algorithm in lower extremity CT angiography. Methods The CT data of the 120-kV group (n = 30) were reconstructed with filtered back projection (FBP) algorithm. The CT data of the 100-kV group (n = 30) were reconstructed with FBP as well as AIDR-3D algorithms. Results The 100-kV group showed significantly lower dose-length product than the 120-kV group (P < 0.05). In comparison with the 120-kV and FBP protocol, the 100-kV and FBP protocol showed significantly increased vascular density and noise (P < 0.05). However, in the 100-kV group, images reconstructed with AIDR-3D showed significantly lower noise and significantly higher signal-to-noise ratio and contrast-to-noise ratio than FBP (P < 0.05). Conclusions Low-tube-voltage (100 kV) 320-row CT in combination with AIDR-3D reconstruction can significantly improve the image quality and reduce radiation dose of lower extremity CT angiography.
引用
收藏
页码:272 / 276
页数:5
相关论文
共 50 条
  • [21] Estimated Radiation Dose of Coronary Computed Tomography Angiography Using Adaptive Statistical Iterative Reconstruction: A Multicenter Study
    LaBounty, Troy M.
    Earls, James
    Leipsic, Jonathon
    Heilbron, Brett
    Mancini, G. B. John
    Lin, Fay Y.
    Min, James K.
    CIRCULATION, 2009, 120 (18) : S334 - S334
  • [22] Low concentration contrast medium for dual-source computed tomography coronary angiography by a combination of iterative reconstruction and low-tube-voltage technique: Feasibility study
    Zheng, Minwen
    Liu, Ying
    Wei, Mengqi
    Wu, Yongjie
    Zhao, Hongliang
    Li, Jian
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (02) : E92 - E99
  • [23] Evaluation of Deep Vein Thrombosis With Reduced Radiation and Contrast Material Dose at Computed Tomography Venography - Clinical Application of a Combined Iterative Reconstruction and Low-Tube-Voltage Technique
    Oda, Seitaro
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Shimonobo, Toshiaki
    Namimoto, Tomohiro
    Itatani, Ryo
    Hirai, Toshinori
    Yamashita, Yasuyuki
    CIRCULATION JOURNAL, 2012, 76 (11) : 2614 - 2622
  • [24] Radiation Dose and Image Noise Evaluation in Coronary Computed Tomography Angiography (CCTA) Using an Iterative Reconstruction Algorithm
    Kordolaimi, Sofia D.
    Argentos, Stylianos
    Stathis, George
    Alexiou, Antigoni
    Pantos, Ioannis
    Katritsis, Demosthenes G.
    Kelekis, Nikolaos L.
    Seimenis, Ioannis
    Efstathopoulos, Efstathios P.
    HELLENIC JOURNAL OF CARDIOLOGY, 2014, 55 (03) : 184 - 190
  • [25] Optimization of hybrid iterative reconstruction level and evaluation of image quality and radiation dose for pediatric cardiac computed tomography angiography
    Yang, Lin
    Zhuang, Jian
    Huang, Meiping
    Liang, Changhong
    Liu, Hui
    PEDIATRIC RADIOLOGY, 2017, 47 (01) : 31 - 38
  • [26] Optimization of hybrid iterative reconstruction level and evaluation of image quality and radiation dose for pediatric cardiac computed tomography angiography
    Lin Yang
    Jian Zhuang
    Meiping Huang
    Changhong Liang
    Hui Liu
    Pediatric Radiology, 2017, 47 : 31 - 38
  • [27] Iterative model reconstruction: Improved image quality of low-tube-voltage prospective ECG-gated coronary CT angiography images at 256-slice CT
    Oda, Seitaro
    Weissman, Gaby
    Vembar, Mani
    Weigold, Wm. Guy
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (08) : 1408 - 1415
  • [28] Influence of adaptive statistical iterative reconstruction algorithm on image quality in coronary computed tomography angiography
    Precht, Helle
    Thygesen, Jesper
    Gerke, Oke
    Egstrup, Kenneth
    Waaler, Dag
    Lambrechtsen, Jess
    ACTA RADIOLOGICA OPEN, 2016, 5 (12):
  • [29] Impact of Knowledge-Based Iterative Model Reconstruction on Image Quality and Hemodynamic Parameters in Dynamic Myocardial Computed Tomography Perfusion Using Low-Tube-Voltage Scan: A Feasibility Study
    Tanabe, Yuki
    Kido, Teruhito
    Kurata, Akira
    Kouchi, Takanori
    Hosokawa, Takaaki
    Nishiyama, Hikaru
    Kawaguchi, Naoto
    Kido, Tomoyuki
    Uetani, Teruyoshi
    Mochizuki, Teruhito
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (05) : 811 - 816
  • [30] A deep-learning reconstruction algorithm that improves the image quality of low-tube-voltage coronary CT angiography
    Wang, Mengzhen
    Fan, Jing
    Shi, Xiaofeng
    Qin, Le
    Yan, Fuhua
    Yang, Wenjie
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 146