High contrast cartilaginous endplate imaging using a 3D adiabatic inversion-recovery-prepared fat-saturated ultrashort echo time (3D IR-FS-UTE) sequence

被引:7
|
作者
Lombardi, Alecio F. [1 ,2 ]
Wei, Zhao [1 ]
Wong, Jonathan [1 ,2 ]
Carl, Michael [3 ]
Lee, Roland R. [1 ]
Wallace, Mark [4 ]
Masuda, Koichi [5 ]
Chang, Eric Y. [1 ,2 ]
Du, Jiang [1 ]
Ma, Ya-Jun [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, 9452 Med Ctr Dr, San Diego, CA 92037 USA
[2] Vet Affairs San Diego Healthcare Syst, Res Serv, San Diego, CA USA
[3] GE Healthcare, San Diego, CA USA
[4] Univ Calif San Diego, Dept Anesthesiol, San Diego, CA 92103 USA
[5] Univ Calif San Diego, Dept Orthoped Surg, San Diego, CA 92103 USA
关键词
adiabatic inversion recovery; cartilaginous endplate; ultrashort echo time; VERTEBRAL ENDPLATE; MRI; EXCITATION; DISEASE; SPINE;
D O I
10.1002/nbm.4579
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Ultrashort echo time (UTE) sequences can image tissues with transverse T (2)/T (2)* relaxations too short to be efficiently observed on routine clinical MRI sequences, such as the vertebral body cartilaginous endplate (CEP). Here, we describe a 3D adiabatic inversion-recovery-prepared fat-saturated ultrashort echo time (3D IR-FS-UTE) sequence to highlight the CEP of vertebral bodies in comparison to the intervertebral disc (IVD) and bone marrow fat (BF) at 3 T. The IR-FS-UTE sequence used a 3D UTE sequence combined with an adiabatic IR preparation pulse centered in the middle of the water and fat peaks, while a fat saturation module was used to suppress the signal from fat. A slab-selective half pulse was used for signal excitation, and a 3D center-out cones trajectory was used for more efficient data sampling. The 3D IR-FS-UTE sequence was applied to an ex vivo human spine sample, as well as the spines of six healthy volunteers and of three patients with back pain. Bright continuous lines representing signal from CEP were found in healthy IVDs. The measured contrast-to-noise ratio was 18.5 +/- 4.9 between the CEP and BF, and 20.3 +/- 4.15 between the CEP and IVD for the six volunteers. Abnormal IVDs showed CEP discontinuity or irregularity in the sample and patient studies. In conclusion, the proposed 3D IR-FS-UTE sequence is feasible for imaging the vertebral body's CEP in vivo with high contrast.
引用
收藏
页数:11
相关论文
共 50 条
  • [11] Water phase transition and signal nulling in 3D dual-echo adiabatic inversion-recovery UTE (IR-UTE) imaging of myelin
    Athertya, Jiyo S.
    Shin, Soo Hyun
    Malhi, Bhavsimran Singh
    Lo, James
    Sedaghat, Sam
    Jang, Hyungseok
    Ma, Yajun
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2024, : 2464 - 2472
  • [12] Whole-Brain Myelin Imaging Using 3D Double-Echo Sliding Inversion Recovery Ultrashort Echo Time (DESIRE UTE) MRI
    Ma, Ya-Jun
    Searleman, Adam C.
    Jang, Hyungseok
    Wong, Jonathan
    Chang, Eric Y.
    Corey-Bloom, Jody
    Bydder, Graeme M.
    Du, Jiang
    RADIOLOGY, 2020, 294 (02) : 362 - 374
  • [13] Water phase transition and signal nulling in 3D dual-echo adiabatic inversion-recovery UTE (IR-UTE) imaging of myelin
    Athertya, Jiyo S.
    Shin, Soo Hyun
    Malhi, Bhavsimran Singh
    Lo, James
    Sedaghat, Sam
    Jang, Hyungseok
    Ma, Yajun
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (06) : 2464 - 2472
  • [14] Volumetric imaging of myelin in vivo using 3D inversion recovery-prepared ultrashort echo time cones magnetic resonance imaging
    Ma, Ya-Jun
    Searleman, Adam C.
    Jang, Hyungseok
    Fan, Shu-Juan
    Wong, Jonathan
    Xue, Yanping
    Cai, Zhenyu
    Chang, Eric Y.
    Corey-Bloom, Jody
    Du, Jiang
    NMR IN BIOMEDICINE, 2020, 33 (10)
  • [15] Quantitative assessment of articular cartilage degeneration using 3D ultrashort echo time cones adiabatic T1ρ (3D UTE-Cones-AdiabT1ρ) imaging
    Wu, Mei
    Ma, Ya-Jun
    Liu, Mouyuan
    Xue, Yanping
    Gong, Lillian
    Wei, Zhao
    Jerban, Saeed
    Jang, Hyungseok
    Chang, Douglas G.
    Chang, Eric Y.
    Ma, Liheng
    Du, Jiang
    EUROPEAN RADIOLOGY, 2022, 32 (09) : 6178 - 6186
  • [16] Quantitative assessment of articular cartilage degeneration using 3D ultrashort echo time cones adiabatic T1ρ (3D UTE-Cones-AdiabT1ρ) imaging
    Mei Wu
    Ya-Jun Ma
    Mouyuan Liu
    Yanping Xue
    Lillian Gong
    Zhao Wei
    Saeed Jerban
    Hyungseok Jang
    Douglas G. Chang
    Eric Y Chang
    Liheng Ma
    Jiang Du
    European Radiology, 2022, 32 : 6178 - 6186
  • [17] Improved volumetric myelin imaging in human brain using 3D dual echo inversion recovery-prepared UTE with complex echo subtraction
    Tang, Hyungseok
    Wei, Zhao
    Wu, Mei
    Ma, Ya-Jun
    Chang, Eric Y.
    Corey-Bloom, Jody
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (04) : 1168 - 1177
  • [18] To measure T1 of short T2 species using an inversion recovery prepared three-dimensional ultrashort echo time (3D IR-UTE) method: A phantom study
    Wei, Zhao
    Ma, Ya-Jun
    Jang, Hyungseok
    Yang, Wenhui
    Du, Jiang
    JOURNAL OF MAGNETIC RESONANCE, 2020, 314
  • [19] MRI Characterization of 3D Printed Anatomic Models Using a Dual-Echo Ultrashort TE (UTE) Sequence
    Wake, N.
    Peng, Q.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [20] Myelin Imaging in Human Brain Using a Short Repetition Time Adiabatic Inversion Recovery Prepared Ultrashort Echo Time (STAIR-UTE)MRI Sequence in Multiple Sclerosis
    Ma, Ya-Jun
    Jang, Hyungseok
    Wei, Zhao
    Cai, Zhenyu
    Xue, Yanping
    Lee, Roland R.
    Chang, Eric Y.
    Bydder, Graeme M.
    Corey-Bloom, Jody
    Du, Jiang
    RADIOLOGY, 2020, 297 (02) : 392 - 404