Biomechanical evaluation of different types of lateral hinge fractures in medial opening wedge high tibial osteotomy

被引:12
|
作者
Chen, Peng [1 ]
Zhan, Yu [2 ]
Zhan, Shi [2 ]
Li, Ruiyang [2 ]
Luo, Congfeng [2 ]
Xie, Xuetao [2 ]
机构
[1] Zhejiang Sian Int Hosp, Dept Orthopaed Surg, 2369 Hongxing Rd, Jiaxing 314000, Zhejiang, Peoples R China
[2] Shanghai Jiao Tong Univ Affiliated Peoples Hosp 6, Dept Orthopaed Surg, 600 Yishan Rd, Shanghai 200233, Peoples R China
基金
中国国家自然科学基金;
关键词
CLASSIFICATION; PREVENTION; STABILITY;
D O I
10.1016/j.clinbiomech.2021.105295
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Lateral hinge fractures are common complications in the medial opening wedge high tibial osteotomy for treatment of knee osteoarthritis. The rehabilitation protocols are decided depending on the remaining stability following these fractures. This study aimed to evaluate the biomechanical properties of different types of lateral hinge fractures in medial opening wedge high tibial osteotomy. Methods: Twenty synthetic tibia models were used as test samples. A 10-mm bone wedge was removed from the medial side of the proximal tibias to create the bone defect. The samples were then divided into 4 groups: (1) intact lateral hinge; (2) Takeuchi type I fractures; (3) type II fractures; and (4) type III fractures. After fixation with a locking plate, the stability parameters including construct stiffness, wedge displacement, and construct strength were tested under compressive forces and compared among the 4 groups. Findings: No statistical difference was found in the construct stiffness among the 4 groups (P = 0.78). The type III fractures had the largest wedge displacement compared with the other 3 groups. The failure loads on average were significantly reduced in the type III fractures compared with those with intact hinge (P < 0.01) and in type I fractures (P = 0.04). No statistical difference was observed between the type I fractures and the intact hinge in terms of wedge displacement or failure loads. Interpretation: The type III fractures were the most unstable and patients with these fractures should be managed cautiously. Delayed weightbearing and/or additional fixation should be considered.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Uniplane medial opening wedge high tibial osteotomy relative to a biplane osteotomy can reduce the incidence of lateral-hinge fracture
    Nha, Kyung Wook
    Shin, Myung Jin
    Suh, Dong Won
    Nam, Young Jun
    Kim, Ki Seong
    Kyung, Bong Soo
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (05) : 1436 - 1444
  • [22] Incidence and Factors Affecting the Occurrence of Lateral Hinge Fracture After Medial Opening-Wedge High Tibial Osteotomy
    Lee, Sang-June
    Kim, Jae-Hwa
    Baek, Eugene
    Ryu, Han-Seung
    Han, Donghun
    Choi, Wonchul
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2021, 9 (10)
  • [23] Medial Opening Wedge High Tibial Osteotomy in Knee Osteoarthritis-A Biomechanical Approach
    Cofaru, Nicolae Florin
    Roman, Mihai Dan
    Cofaru, Ileana Ioana
    Oleksik, Valentin Stefan
    Fleaca, Sorin Radu
    APPLIED SCIENCES-BASEL, 2020, 10 (24): : 1 - 20
  • [24] The effect of the distance between the end point of the osteotomy and the lateral cortex on the lateral cortical hinge fracture in medial opening-wedge high tibial osteotomy
    Turkmen, Faik
    Kacira, Burkay Kutluhan
    Ozera, Mustafa
    Elibolb, Fatma Kubra Erbay
    Bilgea, Onur
    Demirc, Teyfik
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (11): : 3828 - 3832
  • [25] Biomechanical evaluation of a newly designed locking plate for opening wedge high tibial osteotomy: stress distribution and stability in the presence of lateral hinge fracture
    Park, Hyung Jun
    Suh, Dong Hun
    Hong, Hyongtaek
    Nha, Kyung-Wook
    Kim, Hyungsuh
    Kang, Kyoung-Tak
    Kim, Jae Gyoon
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [26] Effects of different hinge positions on tibial rotation in uniplanar medial opening wedge high tibial osteotomy with three-dimensional tibial models
    Jing, Lizhong
    Ren, Yulian
    Wang, Shaoshan
    Yang, Jiushan
    Wang, Jian
    FRONTIERS IN SURGERY, 2024, 11
  • [27] Biomechanical evaluation of different fixation plates in medial opening upper tibial osteotomy
    Esenkaya, Irfan
    Misirlioglu, Mesut
    Kelestemur, M. Halidun
    Elmali, Nurzat
    Fadillioglu, Ersin
    KNEE, 2007, 14 (01): : 46 - 50
  • [28] Early experience of lateral hinge fracture during medial opening-wedge high tibial osteotomy: incidence and clinical outcomes
    Song, Kwang Yun
    Koh, In Jun
    Kim, Man Soo
    Choi, Nam Yong
    Jeong, Ji Hwan
    In, Yong
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (02) : 161 - 169
  • [29] Fixation of Takeuchi Type II/III lateral hinge fractures provides favourable stability of a medial open wedge high tibial osteotomy-A biomechanical study
    Peez, Christian
    Deichsel, Adrian
    Zderic, Ivan
    Richards, R. Geoff
    Drenchev, Ludmil
    Skulev, Hristo K.
    Gueorguiev, Boyko
    Raschke, Michael J.
    Kittl, Christoph
    Herbst, Elmar
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2024,
  • [30] Early experience of lateral hinge fracture during medial opening-wedge high tibial osteotomy: incidence and clinical outcomes
    Kwang Yun Song
    In Jun Koh
    Man Soo Kim
    Nam Yong Choi
    Ji Hwan Jeong
    Yong In
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 161 - 169