Biomechanical evaluation of different types of lateral hinge fractures in medial opening wedge high tibial osteotomy

被引:12
|
作者
Chen, Peng [1 ]
Zhan, Yu [2 ]
Zhan, Shi [2 ]
Li, Ruiyang [2 ]
Luo, Congfeng [2 ]
Xie, Xuetao [2 ]
机构
[1] Zhejiang Sian Int Hosp, Dept Orthopaed Surg, 2369 Hongxing Rd, Jiaxing 314000, Zhejiang, Peoples R China
[2] Shanghai Jiao Tong Univ Affiliated Peoples Hosp 6, Dept Orthopaed Surg, 600 Yishan Rd, Shanghai 200233, Peoples R China
基金
中国国家自然科学基金;
关键词
CLASSIFICATION; PREVENTION; STABILITY;
D O I
10.1016/j.clinbiomech.2021.105295
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Lateral hinge fractures are common complications in the medial opening wedge high tibial osteotomy for treatment of knee osteoarthritis. The rehabilitation protocols are decided depending on the remaining stability following these fractures. This study aimed to evaluate the biomechanical properties of different types of lateral hinge fractures in medial opening wedge high tibial osteotomy. Methods: Twenty synthetic tibia models were used as test samples. A 10-mm bone wedge was removed from the medial side of the proximal tibias to create the bone defect. The samples were then divided into 4 groups: (1) intact lateral hinge; (2) Takeuchi type I fractures; (3) type II fractures; and (4) type III fractures. After fixation with a locking plate, the stability parameters including construct stiffness, wedge displacement, and construct strength were tested under compressive forces and compared among the 4 groups. Findings: No statistical difference was found in the construct stiffness among the 4 groups (P = 0.78). The type III fractures had the largest wedge displacement compared with the other 3 groups. The failure loads on average were significantly reduced in the type III fractures compared with those with intact hinge (P < 0.01) and in type I fractures (P = 0.04). No statistical difference was observed between the type I fractures and the intact hinge in terms of wedge displacement or failure loads. Interpretation: The type III fractures were the most unstable and patients with these fractures should be managed cautiously. Delayed weightbearing and/or additional fixation should be considered.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Incidence and risk factors for lateral hinge fractures in medial opening wedge high tibial osteotomy and medial opening wedge distal tibial tuberosity osteotomy
    Ogawa, Hiroyasu
    Nakamura, Yutaka
    Matsumoto, Kazu
    Akiyama, Haruhiko
    KNEE, 2023, 44 : 245 - 252
  • [2] Biomechanical effect of a lateral hinge fracture for a medial opening wedge high tibial osteotomy: finite element study
    Kang, Kyoung-Tak
    Koh, Yong-Gon
    Lee, Jin-Ah
    Lee, Jae Jung
    Kwon, Sae Kwang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [3] Biomechanical effect of a lateral hinge fracture for a medial opening wedge high tibial osteotomy: finite element study
    Kyoung-Tak Kang
    Yong-Gon Koh
    Jin-Ah Lee
    Jae Jung Lee
    Sae Kwang Kwon
    Journal of Orthopaedic Surgery and Research, 15
  • [4] Lateral hinge fracture in medial opening wedge high tibial osteotomy: a narrative review
    Franulic, Nicolas
    Munoz, Jose Tomas
    Figueroa, Francisco
    Innocenti, Piero
    Gaggero, Nicolas
    EFORT OPEN REVIEWS, 2023, 8 (07) : 572 - 580
  • [5] Fractures Around the Lateral Cortical Hinge After a Medial Opening-Wedge High Tibial Osteotomy: A New Classification of Lateral Hinge Fracture
    Takeuchi, Ryohei
    Ishikawa, Hiroyuki
    Kumagai, Ken
    Yamaguchi, Yuichiro
    Chiba, Naoki
    Akamatsu, Yasushi
    Saito, Tomoyuki
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2012, 28 (01): : 85 - 94
  • [6] Lateral hinge fractures in open wedge high tibial osteotomy
    Schoeter, S.
    Ateschrang, A.
    Ihle, C.
    Stoeckle, U.
    Konstantinidis, L.
    Doebele, S.
    ORTHOPADE, 2014, 43 (11): : 1000 - 1007
  • [7] Biomechanical insights to mitigate lateral hinge fracture risk in opening-wedge high tibial osteotomy
    Wu, Haoyue
    Jung, Kyung-Hwan
    Na, Xinyu
    Kwon, Jong-Hyeok
    Heo, Jeong-Min
    Kwon, Dae-Seo
    Kim, Dong-Kyu
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2025,
  • [8] Computational comparison of different plating strategies in medial open-wedge high tibial osteotomy with lateral hinge fractures
    Yen-Nien Chen
    Chang-Han Chuang
    Tai-Hua Yang
    Chih-Wei Chang
    Chun-Ting Li
    Chia-Jung Chang
    Chih-Han Chang
    Journal of Orthopaedic Surgery and Research, 15
  • [9] Computational comparison of different plating strategies in medial open-wedge high tibial osteotomy with lateral hinge fractures
    Chen, Yen-Nien
    Chuang, Chang-Han
    Yang, Tai-Hua
    Chang, Chih-Wei
    Li, Chun-Ting
    Chang, Chia-Jung
    Chang, Chih-Han
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [10] Effect of Tibial Cut Planes and Hinge Axes on Medial Opening Wedge High Tibial Osteotomy
    Park, Byoung-Keon
    Lee, Ho-sang
    Kim, Jay-Jung
    Kim, Cheol-Woong
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS A, 2011, 35 (08) : 835 - 846