A high-order prior for overlapped projections in the real flat-panel x-ray source imaging system

被引:1
|
作者
Duan, Jiayu [1 ]
Wang, Tianquan [2 ]
Li, Yang [1 ]
Mou, Xuanqin [1 ]
机构
[1] Xi An Jiao Tong Univ, Xian 710049, Shaanxi, Peoples R China
[2] Sun Yat Sen Univ, Canc Ctr, Guangzhou 510000, Guangdong, Peoples R China
来源
关键词
filed-emission; cold cathode; flat-panel x-ray source; high-order prior; FABRICATION; EMITTER;
D O I
10.1117/12.2594139
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
With the appearance of the field-emission cold cathode x-ray source, the fast response and small in size innovate the traditional imaging system. Although the field-emission x-ray source array generates multiple novel imaging modalities, it still faces a long stand-off distance between source and object. To realize a portable, smart, extremely low dose imaging modality, researchers proposed a concept to design a two-dimensional array field-emission source, namely the flat-panel source. In this paper, a real imaging system based on the ZnO field-emission flat-panel source is designed. Currently, the real flat-panel source faces an extremely low dose and non-addressable situation. Hence, the measurement based on the flat-panel source is overlapped and without an application potential. We first try to realize the imaging ability of the flat-panel source by designing a rebinning algorithm. With the analysis on the overlapped measurement, a high-order prior is introduced into the rebinning algorithm to improve the performance. Simulation and real data experiments verified our proposed method. Compared to the no high-order prior, the proposed algorithm can recover a more distinct measurement.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Real-time flat-panel pixel imaging system and control for X-ray and neutron detection
    Chapuy, S
    Dimcovski, M
    Dimcovski, Z
    Lehmann, EH
    Pachoud, M
    Valley, JF
    Verdun, FR
    Vontobel, P
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (06) : 2357 - 2364
  • [2] A Monte Carlo simulation study of a flat-panel X-ray source
    Grant, Edwin J.
    Posada, Chrystian M.
    Castano, Carlos H.
    Lee, Hyoung K.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (08) : 1658 - 1666
  • [3] High resolution x-ray imaging using amorphous silicon flat-panel arrays
    Xerox Palo Alto Research Cent, Palo Alto, United States
    IEEE Nucl Sci Symp Med Imaging Conf, (1073-1077):
  • [4] High resolution x-ray imaging using amorphous silicon flat-panel arrays
    Rahn, JT
    Lemmi, F
    Lu, JP
    Mei, P
    Apte, RB
    Street, RA
    Lujan, R
    Weisfield, RL
    Heanue, JA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) : 457 - 461
  • [5] A flat-panel X-ray imaging module for medical imaging and nondestructive testing
    Cho, Hyosung
    Choi, Sungil
    Lee, Bongsoo
    Kim, Sin
    ADVANCED NONDESTRUCTIVE EVALUATION I, PTS 1 AND 2, PROCEEDINGS, 2006, 321-323 : 1004 - 1007
  • [6] Flat-panel detectors in X-ray systems
    Spahn, M
    Heer, V
    Freytag, R
    RADIOLOGE, 2003, 43 (05): : 340 - +
  • [7] Scintillator-based flat-panel x-ray imaging detectors
    Granfors, Paul R.
    Albagli, Douglas
    JOURNAL OF THE SOCIETY FOR INFORMATION DISPLAY, 2009, 17 (06) : 535 - 542
  • [8] Enhancing X-ray Emission of Cold Cathode Flat-Panel X-ray Source by Pulsed Driving
    Fan, Ruowen
    Kang, Song
    Zhang, Guofu
    She, Juncong
    Deng, Shaozhi
    Chen, Jun
    2024 37TH INTERNATIONAL VACUUM NANOELECTRONICS CONFERENCE, IVNC 2024, 2024,
  • [9] High resolution flat-panel X-ray detector for digital radiography
    Park, JK
    Kang, SS
    Cha, BY
    Kim, JY
    Kim, SY
    Choi, HK
    Nam, SH
    Healthcom 2005: 7th International Workshop on Enterprise Networking and Computing in Healthcare Industry, Proceedings, 2005, : 359 - 363
  • [10] A new x-ray imaging technique for radiography mode of flat-panel imager
    Suzuki, K.
    Ikeda, S.
    Ueda, K.
    Baba, R.
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510