Numerical and experimental studies of flat-walled diffuser elements for valve-less micropumps

被引:164
|
作者
Olsson, A [1 ]
Stemme, G [1 ]
Stemme, E [1 ]
机构
[1] Royal Inst Technol, Dept Signals Sensors & Syst, SE-10044 Stockholm, Sweden
关键词
flat-walled diffuser element; valve-less micropump; flow-directing capability;
D O I
10.1016/S0924-4247(99)00320-9
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An investigation of flat-walled diffuser elements for valve-less micropumps is presented. The diffuser element is a small angle flow channel with a rounded inlet and a preferably sharp outlet. The diverging-wall direction is the positive flow direction. The flow-directing capability under steady flow conditions was determined experimentally for several different diffuser elements. The flow-pressure characteristic was studied in detail for one of them. The result is compared with previously published results on pump performance. Numerical simulations were done using the Computational Fluid Dynamics program ANSYS/Flotran. The simulations show the flow-directing capability of the diffuser elements and predict the flow-pressure characteristics well for Reynolds numbers below 300-400. For higher Reynolds numbers, the simulations show the flow-directing capability, but there is a larger discrepancy between simulations and measurements. Simulations were also done for a nozzle element, a wide-angle flow channel with sharp inlet and outlets used in the micropump with dynamic passive-valves. A nozzle element has the converging-wall direction as positive flow direction. The simulations show differences in the flow patterns for diffuser elements and nozzle elements that explain the opposite positive flow directions. The diffuser element has an ordered flow and takes advantage of the pressure recovery in the diverging-wall direction. The nozzle element has gross flow separation in the diverging-wall direction and there is a "vena-contracta" effect instead of pressure recovery. The effective cross-sectional area is smaller in the diverging-wall direction than in the converging-wall direction. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:165 / 175
页数:11
相关论文
共 50 条
  • [21] PUMP HEAD IMPROVEMENT OF DIFFUSER/NOZZLE VALVE-LESS MICROPUMP
    Tanaka, Seiichi
    Miyazaki, Koji
    Fujiwara, Seiji
    PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNELS, AND MINICHANNELS, 2013, 2013,
  • [22] Development of diffuser/nozzle based valve-less micro-pump
    Tanaka, Seiichi
    Tsukamoto, Hiroshi
    Miyazaki, Koji
    Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2008, 74 (02): : 323 - 328
  • [23] Principle and experimental verification of valve-less pump
    Zhao L.-Q.
    Ji J.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2019, 27 (12): : 2639 - 2649
  • [24] Numerical and Experimental Study of Valve-Less Micropump Using Dynamic Multiphysics Model
    Wang, Tao
    He, Jian
    Wang, Jiejun
    Lv, Lu
    Li, Qiuyan
    Luo, Wenbo
    Wu, Chuangui
    Shuai, Yao
    Zhang, Wanli
    2018 13TH ANNUAL IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (NEMS 2018), 2018, : 300 - 303
  • [25] Micromachined diffuse nozzle elements for valve-less pumps
    Olsson, A
    Stemme, G
    Stemme, E
    NINTH ANNUAL INTERNATIONAL WORKSHOP ON MICRO ELECTRO MECHANICAL SYSTEMS, IEEE PROCEEDINGS: AN INVESTIGATION OF MICRO STRUCTURES, SENSORS, ACTUATORS, MACHINES AND SYSTEMS, 1996, : 378 - 383
  • [26] Enhancement of synthetic jets by means of an integrated valve-less pump Part II.: Numerical and experimental studies
    Trávnícek, Z
    Tesar, V
    Wang, AB
    SENSORS AND ACTUATORS A-PHYSICAL, 2005, 125 (01) : 50 - 58
  • [27] The effect of the microfluidic diodicity on the efficiency of valve-less rectification micropumps using Lattice Boltzmann Method
    Ahmed Fadl
    Zongqin Zhang
    Sebastian Geller
    Jonas Tölke
    Manfred Krafczyk
    Donna Meyer
    Microsystem Technologies, 2009, 15 : 1379 - 1387
  • [28] The effect of the microfluidic diodicity on the efficiency of valve-less rectification micropumps using Lattice Boltzmann Method
    Fadl, Ahmed
    Zhang, Zongqin
    Geller, Sebastian
    Toelke, Jonas
    Krafczyk, Manfred
    Meyer, Donna
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2009, 15 (09): : 1379 - 1387
  • [29] Numerical simulation for piezoelectric valve-less micro-mixer
    He X.
    Deng X.
    Bi Y.
    Wang J.
    Zhuo H.
    Paiguan Jixie Gongcheng Xuebao/Journal of Drainage and Irrigation Machinery Engineering, 2011, 29 (04): : 292 - 296
  • [30] EXPERIMENTAL STUDIES OF NOZZLE/DIFFUSER MICROPUMPS USING ENHANCEMENT STRUCTURE
    Yang, Kai-Shing
    Chao, Tzu-Feng
    Chen, Ing Youn
    Wang, Chi-Chuan
    PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNELS AND MINICHANNELS, 2010, PTS A AND B, 2011, : 887 - 891