Theoretical and experimental verification of imaging resolution factors in scanning electrochemical microscopy

被引:2
|
作者
Xiong, Qiang [1 ]
Wu, Tao [1 ]
Song, Ranran [1 ]
Zhang, Fan [1 ]
He, Pingang [1 ]
机构
[1] East China Normal Univ, Sch Chem & Mol Engn, 500 Dongchuan Rd, Shanghai 200241, Peoples R China
基金
中国国家自然科学基金;
关键词
Gold - Scanning probe microscopy - Analytic equipment - Scanning electron microscopy - Electrochemical electrodes;
D O I
10.1039/d1ay00025j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The imaging resolution of scanning electrochemical microscopy (SECM) depends strongly on the tip electrode size and the tip-substrate distance. Herein, etched glass encapsulation was applied to fabricate a gold disk electrode, and the size of the tip electrode was accurately determined from the steady-state limiting current. Referring to the theoretical research carried out by our predecessors, the formula for the imaging resolution was derived, followed by the imaging of gold spots and cells with the prepared microelectrodes of different sizes and with different tip-substrate distances. A depth scan was performed to generate 2D current maps of the gold spot relative to the position of the microelectrode in the x-z plane. Probe approach curves and horizontal sweeps were obtained from one depth scan image by simply extracting vertical and horizontal cross-sectional lines, and further characterized by comparison with simulated curves through modeling of the experimental system. The experimental results were basically consistent with the theory, revealing that the highest imaging resolution can be obtained with the smallest tip electrode when d/a = 1, and when the size of the tip electrode is fixed the smallest tip-substrate distance can give the highest imaging resolution.
引用
收藏
页码:1238 / 1246
页数:9
相关论文
共 50 条
  • [41] Scanning electrochemical microscopy imaging with laser-pulled probes
    Li, Michelle S. M.
    Filice, Fraser P.
    Ding, Zhifeng
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 781 : 126 - 135
  • [42] Imaging of diaphorase micropatterned at gold arrays with scanning electrochemical microscopy
    Yasukawa, T
    Kanaya, N
    Mandler, D
    Matsue, T
    CHEMISTRY LETTERS, 2000, (05) : 458 - 459
  • [43] Scanning electrochemical microscopy of model neurons: Constant distance imaging
    Kurulugama, RT
    Wipf, DO
    Takacs, SA
    Pongmayteegul, S
    Garris, PA
    Baur, JE
    ANALYTICAL CHEMISTRY, 2005, 77 (04) : 1111 - 1117
  • [44] Local electrochemiluminescence imaging using scanning electrochemical cell microscopy
    Deng, Yufei
    He, Xiaofan
    Jin, Rong
    Jiang, Dechen
    Fang, Danjun
    ELECTROCHEMISTRY COMMUNICATIONS, 2024, 164
  • [45] Scanning Electrochemical Cell Microscopy Platform for Ultrasensitive Photoelectrochemical Imaging
    Aaronson, Barak D. B.
    Byers, Joshua C.
    Colburn, Alex W.
    McKelvey, Kim
    Unwin, Patrick R.
    ANALYTICAL CHEMISTRY, 2015, 87 (08) : 4129 - 4133
  • [46] ELECTRODE FABRICATION FOR SCANNING ELECTROCHEMICAL MICROSCOPY AND SHEAR FORCE IMAGING
    Northcutt, Robert
    Maddox, Jacob
    Sundaresan, Vishnu-Baba
    PROCEEDINGS OF THE ASME CONFERENCE ON SMART MATERIALS, ADAPTIVE STRUCTURES AND INTELLIGENT SYSTEMS, 2016, VOL 2, 2016,
  • [47] Addressable microelectrode arrays: Characterization by imaging with scanning electrochemical microscopy
    Zoski, CG
    Simjee, N
    Guenat, O
    Koudelka-Hep, M
    ANALYTICAL CHEMISTRY, 2004, 76 (01) : 62 - 72
  • [48] Optimal conditions for imaging in scanning tunneling microscopy: Experimental
    Anguiano, E
    Oliva, AI
    Aguilar, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (11): : 3875 - 3878
  • [49] Scanning electrochemical microscopy
    Ricken, C
    Borgwarth, K
    Heinze, J
    NACHRICHTEN AUS CHEMIE TECHNIK UND LABORATORIUM, 1996, 44 (05): : 502 - +
  • [50] SCANNING ELECTROCHEMICAL MICROSCOPY
    ENGSTROM, RC
    PHARR, CM