Electrochemical Impedance-Based Biosensors for the Label-Free Detection of the Nucleocapsid Protein from SARS-CoV-2

被引:31
|
作者
Cho, Hana [1 ,2 ]
Shim, Suhyun [1 ]
Cho, Won Woo [3 ]
Cho, Sungbo [4 ]
Baek, Hanseung [5 ]
Lee, Sang-Myung [3 ]
Shin, Dong-Sik [1 ,2 ]
机构
[1] Sookmyung Womens Univ, Dept Chem & Biol Engn, Seoul 04310, South Korea
[2] Sookmyung Womens Univ, Ind Collaborat Ctr, Seoul 04310, South Korea
[3] Cantis Inc, Ansan 15588, Gyeonggi Do, South Korea
[4] Gachon Univ, Dept Elect Engn, Seongnam Si 13120, Gyeonggi Do, South Korea
[5] Purme Nexon Children Rehabil Hosp, Comprehens Dent Care Ctr, Seoul 03918, South Korea
基金
新加坡国家研究基金会;
关键词
electrochemical sensor; nucleocapsid protein; SARS-CoV-2; impedance; label-free detection; FLOW IMMUNO ASSAY; FLUORESCENCE; PCR;
D O I
10.1021/acssensors.2c00317
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Diagnosis of coronavirus disease (COVID-19) is important because of the emergence and global spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Real-time polymerase chain reaction (PCR) is widely used to diagnose COVID-19, but it is time-consuming and requires sending samples to test centers. Thus, the need to detect antigens for rapid on-site diagnosis rather than PCR is increasing. We quantified the nucleocapsid (N) protein in SARS-CoV-2 using an electro-immunosorbent assay (El-ISA) and a multichannel impedance analyzer with a 96-interdigitated microelectrode sensor (ToAD). The El-ISA measures impedance signals from residual detection antibodies after sandwich assays and thus offers highly specific, label-free detection of the N protein with low cross-reactivity. The ToAD sensor enables the real-time electrochemical detection of multiple samples in conventional 96-well plates. The limit of detection for the N protein was 0.1 ng/mL with a detection range up to 10 ng/mL. This system did not detect signals for the S protein. While this study focused on detecting the N protein in SARS-CoV-2, our system can also be widely applicable to detecting various biomolecules involved in antigen-antibody interactions.
引用
收藏
页码:1676 / 1684
页数:9
相关论文
共 50 条
  • [21] A Label-Free Electrochemical Impedimetric Immunosensor with Biotinylated-Antibody for SARS-CoV-2 Nucleoprotein Detection in Saliva
    Wu, Ching-Chou
    Chiang, Yu-Huan
    Chiang, Hsin-Yu
    BIOSENSORS-BASEL, 2022, 12 (05):
  • [22] Electrochemical Biosensors for the Detection of SARS-CoV-2 and Other Viruses
    Imran, Saim
    Ahmadi, Soha
    Kerman, Kagan
    MICROMACHINES, 2021, 12 (02)
  • [23] A DNA Aptamer Based Method for Detection of SARS-CoV-2 Nucleocapsid Protein
    Chen, Zhiqiang
    Wu, Qihan
    Chen, Jing
    Ni, Xiaohua
    Dai, Jianfeng
    VIROLOGICA SINICA, 2020, 35 (03) : 351 - 354
  • [24] Impedance-Based Neutralizing Antibody Detection Biosensor with Application in SARS-CoV-2 Infection
    Manshadi, Mohammad K. D.
    Mansoorifar, Amin
    Chiao, Jung-Chih
    Beskok, Ali
    ANALYTICAL CHEMISTRY, 2023, 95 (02) : 836 - 845
  • [25] A DNA Aptamer Based Method for Detection of SARS-CoV-2 Nucleocapsid Protein
    Zhiqiang Chen
    Qihan Wu
    Jing Chen
    Xiaohua Ni
    Jianfeng Dai
    Virologica Sinica, 2020, (03) : 351 - 354
  • [26] A DNA Aptamer Based Method for Detection of SARS-CoV-2 Nucleocapsid Protein
    Zhiqiang Chen
    Qihan Wu
    Jing Chen
    Xiaohua Ni
    Jianfeng Dai
    Virologica Sinica, 2020, 35 (03) : 351 - 354
  • [27] Flexible Label-Free Platinum and Bio-PET-Based Immunosensor for the Detection of SARS-CoV-2
    Blasques, Rodrigo Vieira
    de Oliveira, Paulo Roberto
    Kalinke, Cristiane
    Brazaca, Lais Canniatti
    Crapnell, Robert D. D.
    Bonacin, Juliano Alves
    Banks, Craig E. E.
    Janegitz, Bruno Campos
    BIOSENSORS-BASEL, 2023, 13 (02):
  • [28] Impedimetric Detection Based on Label-Free Immunoassay Developed for Targeting Spike S1 Protein of SARS-CoV-2
    Erdem, Arzum
    Senturk, Huseyin
    Yildiz, Esma
    Maral, Meltem
    DIAGNOSTICS, 2022, 12 (08)
  • [29] Electrochemical microfluidic paper-based analytical device for label-free detection of SARS-CoV-2 antigen by LDH redox probe
    Ehzari, Hosna
    Safari, Meysam
    Hallaj, Rahman
    Amiri, Masoud
    MICROCHEMICAL JOURNAL, 2024, 197
  • [30] CRISPR-Cas12a-mediated label-free electrochemical aptamer-based sensor for SARS-CoV-2 antigen detection
    Liu, Na
    Liu, Ran
    Zhang, Jingjing
    BIOELECTROCHEMISTRY, 2022, 146