摘要
Background. The purpose of this study was to have a preliminary assessment of the safety and efficacy of an automated vascular suturing device. Methods. The device (Heartflo, Perclose/Abbott Labs, Redwood City, CA), which delivers 10 interrupted 7-0 polypropylene sutures between side-to-side arteriatomies, was evaluated in animals (8 Yorkshire pigs). Results. Tissue edge capture and quality of anastomosis were highly rated. Time of anastomoses averaged 22 minutes. This time was prolonged primarily due to suture management, tying of interrupted sutures, and learning curve effects. Six of the anastomoses were hemostatic and two required an additional stitch each. Angiography and histology of the anastomosis confirmed patency and quality of the anastomosis. Conclusions. Our preliminary results indicate that the Heartflo automated anastomotic device is safe and effective. Preclinical and clinical studies to validate its acute and long-term effectiveness will commence shortly. (Ann Thorac Surg 2000;70:1046-8) (C) 2000 by The Society of Thoracic Surgeons.
引用
收藏
页码:1046 / 1048
页数:3
相关论文
共 50 条
  • [31] Towards automated coronary artery segmentation: A systematic review
    Gharleghi, Ramtin
    Chen, Nanway
    Sowmya, Arcot
    Beier, Susann
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2022, 225
  • [32] Automated Diagnosis of Coronary Artery Disease: A Review and Workflow
    Mastoi, Qurat-ul-ain
    Teh, Ying Wah
    Raj, Ram Gopal
    Iqbal, Uzair
    CARDIOLOGY RESEARCH AND PRACTICE, 2018, 2018
  • [33] Coronary artery bypass crafting in patients with dialysis-dependent renal failure
    Naruse, Y
    Makuuchi, H
    Kobayashi, T
    Hayashi, I
    Tanaka, K
    Takayama, T
    Namifusa, Y
    ARTIFICIAL ORGANS, 2001, 25 (04) : 260 - 262
  • [34] Coronary-coronary artery bypass
    Dietl, CA
    ANNALS OF THORACIC SURGERY, 1996, 61 (02): : 771 - 771
  • [35] Numerical and Physical Models of Distal Anastomosis in Coronary Artery Bypass Grafting
    Long, Haiyan
    Yang, Gang
    PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE ON BIOLOGICAL ENGINEERING AND PHARMACY (BEP 2016), 2016, 3 : 34 - 38
  • [36] A New Coronary Artery Bypass Graft (CABG) Distal Anastomosis Design
    Kabinejadian, F.
    Chua, L. P.
    Ghista, D. N.
    Tan, Y. S.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 491 - 494
  • [37] INVESTIGATION OF DISTAL SAPHENO-CORONARY ARTERY BYPASS ANASTOMOSIS STENOSIS
    PRIOR, AL
    THORAX, 1981, 36 (01) : 78 - 79
  • [38] Postpartum Spontaneous Coronary Artery Dissection Recovered by Coronary Artery Bypass Grafting Supported With Impella Device
    Nakai, Mai
    Ozaki, Yuichi
    Kitabata, Hironori
    Nishimura, Yoshiharu
    Tanaka, Atsushi
    JOURNAL OF INVASIVE CARDIOLOGY, 2023, 35 (08): : 2 - 2
  • [39] INTERRUPTED WARM BLOOD CARDIOPLEGIA FOR CORONARY-ARTERY BYPASS-GRAFTING
    ISOMURA, T
    HISATOMI, K
    SATO, T
    HAYASHIDA, N
    OHISHI, K
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1995, 9 (03) : 133 - 138
  • [40] DOES ANASTOMOSIS DEVICE OR EPIAORTIC ULTRASONOGRAPHY REDUCE THE RISK OF POSTOPERATIVE STROKE AFTER CORONARY ARTERY BYPASS GRAFTING?
    Biancari, Fausto
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 143 (05): : 1231 - 1232