An automated interrupted suturing device for coronary artery bypass crafting: Automated coronary anastomosis

被引:19
|
作者
Shennib, H
Korkola, SJ
Bousette, N
Giaid, A
机构
[1] Roosevelt & Beth Israel Hosp, Ctr Innovat Cardiovasc Therapy, New York, NY USA
[2] McGill Univ, Ctr Hlth, Montreal, PQ, Canada
来源
ANNALS OF THORACIC SURGERY | 2000年 / 70卷 / 03期
关键词
D O I
10.1016/S0003-4975(00)01792-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The purpose of this study was to have a preliminary assessment of the safety and efficacy of an automated vascular suturing device. Methods. The device (Heartflo, Perclose/Abbott Labs, Redwood City, CA), which delivers 10 interrupted 7-0 polypropylene sutures between side-to-side arteriatomies, was evaluated in animals (8 Yorkshire pigs). Results. Tissue edge capture and quality of anastomosis were highly rated. Time of anastomoses averaged 22 minutes. This time was prolonged primarily due to suture management, tying of interrupted sutures, and learning curve effects. Six of the anastomoses were hemostatic and two required an additional stitch each. Angiography and histology of the anastomosis confirmed patency and quality of the anastomosis. Conclusions. Our preliminary results indicate that the Heartflo automated anastomotic device is safe and effective. Preclinical and clinical studies to validate its acute and long-term effectiveness will commence shortly. (Ann Thorac Surg 2000;70:1046-8) (C) 2000 by The Society of Thoracic Surgeons.
引用
收藏
页码:1046 / 1048
页数:3
相关论文
共 50 条
  • [1] Endoscopic multivessel coronary artery bypass grafting using automated device for proximal anastomosis
    Recanati, MA
    White, JK
    Titus, J
    Agnihotri, AK
    Torchiana, DF
    HEART SURGERY FORUM, 2003, 6 (06): : E80 - E84
  • [2] Automated proximal anastomosis for redo coronary artery bypass grafting through a lateral thoracotomy
    Perreas, KG
    Niranjan, G
    Clark, S
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (02): : 606 - 607
  • [3] Avoiding aortic clamping during coronary artery bypass using an automated anastomotic device
    Endo, M
    Benhameid, O
    Morin, JF
    Shennib, H
    ANNALS OF THORACIC SURGERY, 2002, 73 (03): : 1000 - 1001
  • [4] Evaluation of the enclose proximal anastomosis device in coronary artery bypass grafting
    Aranki, SF
    Shekar, PS
    Ehsan, A
    Byrne-Taft, M
    Couper, GS
    ANNALS OF THORACIC SURGERY, 2005, 80 (03): : 1091 - 1095
  • [5] CORONARY-ARTERY BYPASS CRAFTING IN AN ACHONDROPLASTIC DWARF
    BELAGUER, JM
    PERRY, D
    CROWLEY, J
    MORAN, JM
    TEXAS HEART INSTITUTE JOURNAL, 1995, 22 (03) : 258 - 260
  • [6] Simulation of Anastomosis in Coronary Artery Bypass Surgery
    Hadi Mohammadi
    Bret Nestor
    Guy Fradet
    Cardiovascular Engineering and Technology, 2016, 7 : 432 - 438
  • [7] Simulation of Anastomosis in Coronary Artery Bypass Surgery
    Mohammadi, Hadi
    Nestor, Bret
    Fradet, Guy
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2016, 7 (04) : 432 - 438
  • [8] MORPHOLOGY OF CORONARY ARTERY BYPASS GRAFT ANASTOMOSIS
    GRIFFITH, LS
    BRAWLEY, RK
    HUTCHINS, GM
    AMERICAN JOURNAL OF CARDIOLOGY, 1974, 33 (01): : 141 - 141
  • [9] An automated coronary artery occlusion device for stimulating collateral development in vivo
    Rys, R
    LaDisa, JF
    Tessmer, JP
    Gu, WD
    Kersten, JR
    Warltier, DC
    Pagel, PS
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2002, 48 (02) : 111 - 118
  • [10] Off-pump coronary artery bypass grafting with clampless aortic anastomosis devices: Aortic sealing devices versus automated anastomosis punching
    Gercek, Mustafa
    Skuljevic, Tomislav
    Deutsch, Marcus-Andre
    Gummert, Jan
    Boergermann, Jochen
    JTCVS TECHNIQUES, 2024, 24 : 92 - 104