Improved outcomes with the Prolene Hernia System mesh compared with the time-honored Lichtenstein onlay mesh repair for inguinal hernia repair

被引:35
|
作者
Awad, Samir S. [1 ]
Yallalampalli, Sasi [1 ]
Srour, Ahmad M. [1 ]
Bellows, Charles F. [1 ]
Albo, Daniel [1 ]
Berger, David H. [1 ]
机构
[1] Baylor Coll Med, Michael E DeBakey Vet Affairs Hosp, MED VACL, Michael E deBakey Dept Surg, Houston, TX 77401 USA
来源
AMERICAN JOURNAL OF SURGERY | 2007年 / 193卷 / 06期
关键词
inguinal hernia; open; laparoscopic; anterior; posterior; mesh;
D O I
10.1016/j.amjsurg.2006.08.087
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Inguinal hernia repairs are commonly performed operations. Recently, Neumayer et al examined the gold standard Lichtenstein onlay mesh repair (LMR) against laparoscopic inguinal hernia repair and showed that the recurrence rates are higher for laparoscopic mesh repairs when compared with the open onlay mesh repair (laparoscopic = 10.1% versus open = 4.9%). In 1998, the Prolene Hernia System (pHs) mesh, consisting of an onlay and an underlay patch attached with a connector, was introduced as an option for tension-free open repair of inguinal hernias combining the benefits of a posterior and anterior repair from an open approach. Our objective was to evaluate the PHS mesh repair versus the LMR for inguinal hernias. We hypothesized that the recurrence rate of PM mesh would be lower compared with the LMR with overall similar complication rates. Methods: pHs mesh hernia repairs performed from January 2003 to July 2005 and LMR repairs from January 2000 to July 2002 were included. Demographic data such as age, race, and gender as well as comorbid conditions such as chronic obstructive pulmonary disease, congestive heart failure, previous myocardial infarction, diabetes, hypertension, prostatism, and chronic cough were collected. Complications such as cord injury, seroma, hematoma, urinary retention, urinary tract infection, orchitis, and wound infection were recorded. Recurrences in each group were also recorded. A student t test and chi-square analysis were used for statistical analysis. Results: Six hundred twenty-two charts were reviewed during the 2 time periods (PHS mesh = 321, LMR 302). The median follow-up for the study was 17 months. There was no significant difference with regards to age, race, gender, or comorbidities between the 2 groups. Overall, there was a trend toward decreased complications in the PHS mesh group compared with the LMR group (PHS mesh = 17%, LMR = 23%, P =.07), with a significant difference in the hematoma/seroma rates (PHS mesh = 6.9%, LMR = 12.6%, P =.015). Finally, there was a significant decrease in the recurrence rate for the PHS mesh group when compared with the LMR group (PHS mesh = 0.6%, LMR = 2.7%, P =.04). Conclusion: Our study shows, during a median follow-up of 17 months, improved outcomes by using the PHS mesh compared with the gold standard Lichtenstein onlay mesh for inguinal hernias with significantly lower recurrence rates. Additionally, in the PHS mesh group, there was a trend toward decreased overall complication rates with significantly less seroma/hematoma rates. Therefore, the PHS mesh repair may represent a superior alternative for the repair of inguinal hernias. (C) 2007 Excerpta Medica Inc. All rights reserved.
引用
收藏
页码:697 / 701
页数:5
相关论文
共 50 条
  • [11] Computed Tomographic Appearance of Prolene Hernia System and Polypropylene Mesh Plug Inguinal Hernia Repair
    Yeung, Victor H. W.
    Pearl, Jeffrey M.
    Coakley, Fergus V.
    Joe, Bonnie N.
    Westphalen, Antonio C.
    Yeh, Benjamin M.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2008, 32 (04) : 529 - 532
  • [12] Lichtenstein's Operation, Mesh Plug, or Prolene Hernia System Repair for Groin Hernia: Which is Better?
    Negro, Paolo
    D'Amore, Linda
    Gossetti, Francesco
    ANNALS OF SURGERY, 2010, 252 (01) : 199 - 199
  • [13] Prolene hernia system vs lichtenstein's mesh repair for adult inguinal herniae, a two year reiview
    Daniel, S.
    Yeung, C. K.
    BRITISH JOURNAL OF SURGERY, 2010, 97 : 134 - 134
  • [14] The Prolene Hernia System for inguinal hernia repair
    Slim, K
    Chipponi, J
    ANNALES DE CHIRURGIE, 2003, 128 (02): : 121 - 124
  • [15] Lichtenstein or plug-and-mesh in inguinal hernia repair? - Reply
    Kingsnorth, A
    SURGERY, 2000, 128 (05) : 871 - 871
  • [16] Randomized prospective trial of bilayer prolene hernia system (PHS) versus lichtenstein mesh for inguinal hernia repair under local anaesthesia
    Harris, DA
    Gilmour, J
    Ball, E
    Woodward, A
    BRITISH JOURNAL OF SURGERY, 2002, 89 : 91 - 91
  • [17] Comparative Study of Prolene Hernia System and Lichtenstein Method for Open Inguinal Hernia Repair
    Badkur, Mayank
    Gard, Nitin
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2015, 9 (06) : PC4 - PC7
  • [18] Randomized clinical trial of Lichtenstein patch or Prolene Hernia System® for inguinal hernia repair
    Vironen, J
    Nieminen, J
    Eklund, A
    Paavolainen, P
    BRITISH JOURNAL OF SURGERY, 2006, 93 (01) : 33 - 39
  • [19] Prolene hernia system versus Lichtenstein repair for inguinal hernia: a meta-analysis
    Decker, E.
    Currie, A.
    Baig, M. K.
    HERNIA, 2019, 23 (03) : 541 - 546
  • [20] Prolene hernia system versus Lichtenstein repair for inguinal hernia: a meta-analysis
    E. Decker
    A. Currie
    M. K. Baig
    Hernia, 2019, 23 : 541 - 546