Pleth Variability Index Predicts Fluid Responsiveness in Mechanically Ventilated Adults During General Anesthesia for Noncardiac Surgery

被引:28
|
作者
Siswojo, Andy Sisnata [1 ]
Wong, Daniel Mun-Yen [2 ]
Tuong Dien Phan [2 ]
Kluger, Roman [2 ]
机构
[1] Box Hill Hosp, Dept Anaesthesia, Box Hill, Vic 3128, Australia
[2] St Vincents Hosp, Fitzroy, Vic 3065, Australia
关键词
Pleth variability index; stroke volume; fluid responsiveness; hemodynamic monitoring; pulse oximeter; esophageal Doppler monitoring; RANDOMIZED CONTROLLED-TRIAL; CRITICALLY-ILL PATIENTS; CENTRAL VENOUS-PRESSURE; OF-THE-LITERATURE; CARDIAC-OUTPUT; HOSPITAL STAY; ESOPHAGEAL DOPPLER; PULSE OXIMETER; TRANSESOPHAGEAL DOPPLER; VOLUME;
D O I
10.1053/j.jvca.2014.04.010
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To investigate whether the pleth variability index (PVI), derived noninvasively from a pulse oximeter probe, would predict fluid responsiveness in patients undergoing noncardiac surgeries. Design: A clinical, prospective, observational study. Setting: Operating room of a tertiary care hospital. Participants: Twenty-nine adult patients undergoing a range of noncardiac surgeries, requiring general anesthesia, tracheal intubation, and mechanical ventilation. Interventions: Intravenous volume expansion with 500 mL of colloid following induction of general anesthesia and after a period of hemodynamic stability before the start of surgery. Measurements and Main Results: Baseline values for PVI and stroke volume index, derived from an esophageal Doppler monitor, were compared with final values after the volume expansion. Patients were classified into fluid responders and nonresponders based on a stroke volume index increase of >= 10%. The optimal cut-off value for baseline pleth variability index for predicting fluid responsiveness was determined. There were 17 responders (59%) to the 500-mL volume expansion. Baseline PVI value was significantly different between responders and nonresponders (16.5 +/- 6.4% v 10.3 +/- 2.7%; p = 0.004). Receiver operating characteristic analysis demonstrated significant predictive ability of an increase in stroke volume index for PVI with area under the curve of 0.84 (95% confidence interval = 0.69-0.99). The optimal cut-off value for baseline PVI was 10.5%, with a sensitivity of 88% and a specificity of 67%. Conclusions: Pleth variability index is predictive of fluid responsiveness in adult patients undergoing noncardiac surgery. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1505 / 1509
页数:5
相关论文
共 50 条
  • [31] Reliability of pleth variability index in predicting preload responsiveness of mechanically ventilated patients under various conditions: a systematic review and meta-analysis
    Liu, Tianyu
    Xu, Chao
    Wang, Min
    Niu, Zheng
    Qi, Dunyi
    BMC ANESTHESIOLOGY, 2019, 19 (1)
  • [32] Reliability of pleth variability index in predicting preload responsiveness of mechanically ventilated patients under various conditions: a systematic review and meta-analysis
    Tianyu Liu
    Chao Xu
    Min Wang
    Zheng Niu
    Dunyi Qi
    BMC Anesthesiology, 19
  • [33] Non-invasive prediction of fluid responsiveness in infants using pleth variability index
    Renner, J.
    Broch, O.
    Gruenewald, M.
    Scheewe, J.
    Francksen, H.
    Jung, O.
    Steinfath, M.
    Bein, B.
    ANAESTHESIA, 2011, 66 (07) : 582 - 589
  • [34] Pulse pressure variation and pleth variability index as predictors of fluid responsiveness in patients undergoing spinal surgery in the prone position
    Kim, Do-Hyeong
    Shin, Seokyung
    Kim, Ji Young
    Kim, Seung Hyun
    Jo, Minju
    Choi, Yong Seon
    THERAPEUTICS AND CLINICAL RISK MANAGEMENT, 2018, 14 : 1175 - 1183
  • [35] Evaluation of Hemodynamic Changes and Fluid Response during Anesthesia in Lumbar Disc Hernias with Pleth Variability Index (PVI)
    Sarihan, Seda
    Koyuncu, Tolga
    Kazancioglu, Leyla
    Batcik, Sule
    Kazdal, Hizir
    JOURNAL OF PERSONALIZED MEDICINE, 2024, 14 (03):
  • [36] PLETH VARIABILITY INDEX, PULSE PRESSURE AND STROKE VOLUME VARIATION DO NOT PREDICT FLUID RESPONSIVENESS IN VENTILATED PATIENTS WITH SEPTIC SHOCK TREATED WITH VASOPRESSORS
    Jagannathan, V. K.
    Sharma, S.
    Finn, P.
    Ryan, J.
    Mullenheim, J. W.
    INTENSIVE CARE MEDICINE, 2011, 37 : S89 - S89
  • [37] Pleth variability index and respiratory system compliance to direct PEEP settings in mechanically ventilated patients, an exploratory study
    Zhou, Jing
    Han, Yi
    SPRINGERPLUS, 2016, 5
  • [38] A randomised comparison of Pleth Variability Index (PVI) and oesophageal Doppler for fluid optimisation during major abdominal surgery
    Bahlmann, Hans
    Nilsson, Lena
    Hahn, Robert
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2015, 59 : 6 - 6
  • [39] Does pneumoperitoneum affect perfusion index and pleth variability index in patients receiving combined epidural and general anesthesia?
    Wajima, Zen'ichiro
    Shiga, Toshiya
    Imanaga, Kazuyuki
    BIOSCIENCE TRENDS, 2017, 11 (06) : 667 - 674
  • [40] Stroke volume variation and pleth variability index to predict fluid responsiveness during resection of primary retroperitoneal tumors in Hans Chinese
    Fu, Qiang
    Mi, Weidong
    Zhang, Hong
    BIOSCIENCE TRENDS, 2012, 6 (01) : 38 - 43