Electric Field Calculations on a High Voltage Insulator under Wet Conditions

被引:5
|
作者
Sarang, B. [1 ]
Lakdawala, V. [1 ]
Basappa, P. [2 ]
机构
[1] Old Dominion Univ, Norfolk, VA 23529 USA
[2] Norfolk State Univ, Norfolk, VA USA
关键词
D O I
10.1109/EIC.2009.5166327
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Occurrence of water droplets on outdoor insulators either due to rain, fog, dew etc. leads to localized field enhancement causing partial discharges and dry arcs which ultimately results in complete flashover. Presence of a hydrophobic coating (e.g. RTV coating) inhibits the formation of water films and hence lead to formation of discrete water particles which are less dangerous. In this paper two cases are investigated. The first case refers to the hydrophobic case where water droplets reside as discrete droplets on Silicon Rubber (SIR). The second case is when water droplets coalesce and form a film due to the diminution of the hydrophobic property. The first set of simulations inquired the role of single, multiple discrete water droplets on the shed and the sheath region in enhancing the E-Field. The second set of simulations looked into effect of the water films on the shed region. A High Voltage insulator (138KV) made of SIR is considered to perform the Electric Field Calculations. The first set of results indicates that the water droplets in the sheath region greatly contribute towards enhancing the probability of initiation and progression of wet flashover on insulator surface. The second set of simulations revealed that the E-Field intensification is more when there is abatement of hydrophobic property on the SIR insulators when compared to the discrete droplets case. Simulation was done with the help of a 3D Electric Field Analysis package called COULOMB.
引用
收藏
页码:86 / +
页数:2
相关论文
共 50 条
  • [41] Calculation and analysis on electric field of high gradient insulator
    Ren, Chengyan
    Yuan, Weiqun
    Yan, Ping
    Wang, Jue
    Wang, Jinhua
    2007 IEEE PULSED POWER CONFERENCE, VOLS 1-4, 2007, : 1640 - 1643
  • [42] Methods of electric field intensity reduction under overhead electric power transmission lines of high voltage
    Oleszkiewicz, Pawel
    Nadolny, Zbigniew
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (05): : 196 - 199
  • [43] Effect of electrical stress on glass fiber reinforced polymer used in high voltage composite insulator under wet environment
    Gao, Yanfeng
    Liang, Xidong
    Liu, Yingyan
    Bao, Weining
    Li, Shaohua
    Wu, Chao
    COMPOSITES SCIENCE AND TECHNOLOGY, 2018, 155 : 151 - 159
  • [44] Controlled ice nucleation under high voltage DC electrostatic field conditions
    Orlowska, Marta
    Havet, Michel
    Le-Bail, Alain
    FOOD RESEARCH INTERNATIONAL, 2009, 42 (07) : 879 - 884
  • [45] Simulation Analysis on Reducing the Electric Field Stress at the Triple Junctions & on the Insulator Surface of the High Voltage Vacuum Interrupters
    Venna, Karthik Reddy
    Schramm, Heinz-H.
    PROCEEDINGS OF THE 2014 26TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV-2014), 2014, : 53 - 56
  • [46] INSULATOR FLASHOVER IN SF6 UNDER IMPULSE VOLTAGE CONDITIONS
    ALBAWY, I
    FARISH, O
    IEE PROCEEDINGS-A-SCIENCE MEASUREMENT AND TECHNOLOGY, 1991, 138 (01): : 89 - 97
  • [47] Breakdown electric field calculations of hot SF6 for high voltage circuit breaker applications
    Yousfi, M
    Robin-Jouan, P
    Kanzari, Z
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2005, 12 (06) : 1192 - 1200
  • [49] ELECTRON-TRANSPORT IN INP UNDER HIGH ELECTRIC-FIELD CONDITIONS
    GONZALEZ SANCHEZ, T
    PEREZ, JEV
    CONDE, PMG
    COLLANTES, DP
    SEMICONDUCTOR SCIENCE AND TECHNOLOGY, 1992, 7 (01) : 31 - 36
  • [50] Analysis of electric field influence on buildings under high-voltage transmission lines
    Tong, Ziyuan
    Dong, Zhaoyang
    Ashton, Trevor
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2016, 10 (04) : 253 - 258