Effect of tube potential and luminal contrast attenuation on atherosclerotic plaque attenuation by coronary CT angiography: In vivo comparison with intravascular ultrasound

被引:15
|
作者
Matsumoto, Hidenari [1 ]
Watanabe, Satoshi [2 ]
Kyo, Eisho [2 ]
Tsuji, Takafumi [2 ]
Ando, Yosuke [2 ]
Otaki, Yuka [1 ]
Cadet, Sebastien [1 ]
Slomka, Piotr J. [1 ]
Berman, Daniel S. [1 ,3 ]
Dey, Damini [4 ]
Tamarappoo, Balaji K. [1 ,3 ]
机构
[1] Cedars Sinai Med Ctr, Dept Imaging, Los Angeles, CA 90048 USA
[2] Kusatsu Heart Ctr, Dept Cardiol, Kusatsu, Shiga, Japan
[3] Cedars Sinai Med Ctr, Heart Inst, Los Angeles, CA 90048 USA
[4] Cedars Sinai Med Ctr, Biomed Imaging Res Inst, Los Angeles, CA 90048 USA
关键词
Coronary computed tomography angiography; Plaque characterization; Tube potential; Intravascular ultrasound; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; CLASSIFICATION; ACQUISITION; INJECTION; MORTALITY; SOCIETY; DISEASE; VOLTAGE;
D O I
10.1016/j.jcct.2019.02.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: It has been shown that CT attenuation of noncalcified plaques depends on luminal contrast attenuation (LCA). Although tube potential (kilovolt [kV]) has been shown to exert influence on plaque attenuation through LCA as well as its direct effects, in-vivo studies have not investigated plaque attenuation at lower tube potentials less than 120 kV. We sought to evaluate the effect of kV and LCA on thresholds for lipid-rich and fibrous plaques as defined by intravascular ultrasound (IVUS). Methods: CT attenuation of IVUS-defined plaque components (lipid-rich, fibrous, and calcified plaques) were quantified in 52 consecutive patients with unstable angina, who had coronary CT angiography performed at 100 kV (n = 25) or 120 kV (n = 27) using kV-adjusted contrast protocol prior to IVUS. CT attenuation of plaque components was compared between the two groups. Results: LCA was similar in the 100-kV and 120-kV groups (417.6 +/- 83.7 Hounsfield Units [HU] vs 421.3 +/- 54.9 HU, p = 0.77). LCA correlated with CT attenuation of lipid-rich (r = 0.49, p = 0.001) and fibrous plaques (r = 0.32, p < 0.05), but not with that of calcified plaques (r = 0.04, p = 0.81). When plaque attenuation was normalized to LCA, lipid-rich (0.087 +/- 0.036, range - 0.012-0.147) and fibrous plaque attenuation (0.234 +/- 0.056, range 0.153-0.394) were distinct (p < 0.001) with no overlap for both kV groups. CT attenuation was not significantly different between 100-kV and 120-kV groups for lipid-rich (34.0 +/- 21.5 vs 39.3 +/- 12.9, p = 0.33) or fibrous plaques (95.4 +/- 19.1 vs 97.6 +/- 22.0, p = 0.75). Conclusion: Plaque attenuation thresholds for non-calcified plaque components should be adjusted based on LCA. Further adjustment may not be required for different tube potentials.
引用
收藏
页码:219 / 225
页数:7
相关论文
共 50 条
  • [41] Attenuation-based characterization of coronary atherosclerotic plaque: Comparison of dual source and dual energy CT with single-source CT and histopathology
    Henzler, Thomas
    Porubsky, Stefan
    Kayed, Hany
    Harder, Nils
    Krissak, U. Radko
    Meyer, Mathias
    Sueselbeck, Tim
    Marx, Alexander
    Michaely, Henrik
    Schoepf, U. Joseph
    Schoenberg, Stefan O.
    Fink, Christian
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (01) : 54 - 59
  • [42] Reproducibility, Accuracy, and Predictors of Accuracy for the Detection of Coronary Atherosclerotic Plaque Composition by Computed Tomography An Ex Vivo Comparison to Intravascular Ultrasound
    van der Giessen, Alina G.
    Toepker, Michael H.
    Donelly, Patrick M.
    Bamberg, Fabian
    Schlett, Christopher L.
    Raffle, Christopher
    Irlbeck, Thomas
    Lee, Hang
    van Walsum, Theo
    Maurovich-Horvat, Pal
    Gijsen, Frank J. H.
    Wentzel, Jolanda J.
    Hoffmann, Udo
    INVESTIGATIVE RADIOLOGY, 2010, 45 (11) : 693 - 701
  • [43] In vivo coronary artery plaque assessment with computed tomography angiography: is there an impact of iterative reconstruction on plaque volume and attenuation metrics?
    Chen, Zhongyi
    Boldeanu, Irina
    Nepveu, Simon
    Durand, Madeleine
    Chin, Anne S.
    Kauffmann, Claude
    Mansour, Samer
    Soulez, Gilles
    Tremblay, Cecile
    Chartrand-Lefebvre, Carl
    ACTA RADIOLOGICA, 2017, 58 (06) : 660 - 669
  • [44] Characterization and morphology of atherosclerotic plaque of coronary arteries: Utility of electron-beam tomography to detect non-calcified plaque: A comparison with conventional coronary angiography and intravascular ultrasound
    Funabashi, Nobusada
    Misumi, Kazuo
    Ohnishi, Hiroyuki
    Asano, Miki
    Komuro, Issei
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 115 (01) : 108 - 113
  • [45] LESION-SPECIFIC MEASUREMENTS ON NON-CONTRAST-ENHANCED CORONARY CT STRONGLY CORRELATE WITH PLAQUE BURDEN AND LUMINAL SIZE BY INTRAVASCULAR ULTRASOUND
    Figueroa, Jesus Gustavo Vazquez
    Joshi, Parag H.
    Krivitsky, Eric
    Rinehart, Sarah
    Quian, Zhen
    Shaukat, Ayesha
    Marvasty, Idean B.
    Voros, Szilard
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [46] An intravascular ultrasound anisotropic elasticity-palpography technique for in vivo coronary atherosclerotic plaque detection and characterization
    Gomez, A.
    Tacheau, A.
    Finet, G.
    Coppel, R. D.
    Lagache, M.
    Martiel, J. L.
    Le Floc'h, S.
    Pettigrew, R. I.
    Cloutier, G.
    Ohayon, J.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2017, 20 : 97 - 98
  • [47] Coronary Computed Tomography Angiography-Defined Low Attenuation Plaque to Predict True Lipidic Plaque Determined by Combined Intravascular Imaging
    Wolny, Rafal
    Matsumura, Mitsuaki
    Fujino, Akiko
    Mintz, Gary
    Usui, Eisuke
    Lee, Tetsumin
    Nakanishi, Rine
    Hoshino, Masahiro
    Yonetsu, Taishi
    Kakuta, Tsunekazu
    Maehara, Akiko
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B117 - B117
  • [48] Evaluation of the Effect of Intracoronary Attenuation on Coronary Plaque Measurements Using a Dual-phase Coronary CT Angiography Technique on a 320-row CT Scanner-In Vivo Validation Study
    Kidoh, Masafumi
    Utsunomiya, Daisuke
    Oda, Seitaro
    Funama, Yoshinori
    Nakaura, Takeshi
    Yuki, Hideaki
    Hirata, Kenichiro
    Namimoto, Tomohiro
    Yamashita, Yasuyuki
    ACADEMIC RADIOLOGY, 2016, 23 (03) : 315 - 320
  • [49] Computed Tomographic Attenuation Value of Coronary Atherosclerotic Plaques With Different Tube Voltage: An Ex Vivo Study
    Tanami, Yutaka
    Ikeda, Eiji
    Jinzaki, Masahiro
    Satoh, Kozo
    Nishiwaki, Yuji
    Yamada, Minoru
    Okada, Yasunori
    Kuribayashi, Sachio
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (01) : 58 - 63
  • [50] Standardized volumetric plaque quantification and characterization from coronary CT angiography: a head-to-head comparison with invasive intravascular ultrasound
    Matsumoto, Hidenari
    Watanabe, Satoshi
    Kyo, Eisho
    Tsuji, Takafumi
    Ando, Yosuke
    Otaki, Yuka
    Cadet, Sebastien
    Gransar, Heidi
    Berman, Daniel S.
    Slomka, Piotr
    Tamarappoo, Balaji K.
    Dey, Damini
    EUROPEAN RADIOLOGY, 2019, 29 (11) : 6129 - 6139