Efficacy of multi-electrode duty-cycled radiofrequency ablation for pulmonary vein disconnection in patients with paroxysmal and persistent atrial fibrillation

被引:48
|
作者
Beukema, Rypko P. [1 ]
Beukema, Willem P. [1 ]
Smit, Jaap Jan J. [1 ]
Misier, Anand R. Ramdat [1 ]
Delnoij, Peter Paul H. M. [1 ]
Wellens, Hein [1 ]
Elvan, Arif [1 ]
机构
[1] Isala Klin, Dept Cardiol, NL-8011 JW Zwolle, Netherlands
来源
EUROPACE | 2010年 / 12卷 / 04期
关键词
Atrial fibrillation; Multi-electrode ablation; Pulmonary vein isolation; CATHETER;
D O I
10.1093/europace/euq023
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim A novel multi-electrode pulmonary vein ablation catheter (PVAC) combining circular mapping and duty-cycled multi-electrode radiofrequency (RF) energy delivery has been developed to map and isolate the pulmonary veins (PVs). The aim of this study was to assess the efficacy of multi-electrode RF ablation using the PVAC device. Methods and results A total of 102 consecutive patients, age 57.9 +/- 9.6 years, with paroxysmal or persistent drug refractory atrial fibrillation (AF) were referred for ablation. All patients had documented AF episodes with an AF duration of 9.3 +/- 7.5 years (range 1.5-25). The mean total procedure time was 139.30 +/- 37.72 (median 135, range 115-172). The mean fluoroscopy time required for PVAC ablation was 17 +/- 12 min (median 16, range 12-33) and the total fluoroscopy time was 32.1 +/- 11.3 min (median 29, range 25-39). The mean multi-electrode RF ablation time required to achieve complete PV isolation was 31 +/- 6.7 min (range 16-51). In eight patients with persistent AF, additional ablations were performed to defragment septal and posterior part of the left atrium. In five patients additional RF ablations using conventional catheters were necessary. After multi-electrode duty-cycled RF ablation, 62 of 102 (60.8%) patients were in sustained sinus rhythm without anti-arrhythmic drugs. The mean follow-up duration was 12.2 +/- 3.9 months (range 6-15). Conclusion This novel multi-electrode ablation technique can be used for PV isolation and left atrium ablation with a relatively low medium-term success rate after the first ablation of similar to 61%. Larger studies with longer follow-up are required to evaluate the efficacy and whether multi-electrode RF ablation is associated with a different complication rate compared with standard PV isolation.
引用
收藏
页码:502 / 507
页数:6
相关论文
共 50 条
  • [21] Ablation of atrial fibrillation using a novel duty-cycled phased radiofrequency ablation system
    Deneke, T.
    Buenz, K.
    Balta, O.
    Anders, H.
    Horlitz, M.
    Paesler, M.
    Haberkorn, R.
    Berenjkoub, E.
    Orth, B.
    Shin, D. I.
    EUROPEAN HEART JOURNAL, 2011, 32 : 803 - 803
  • [22] Utility of esophageal temperature monitoring during pulmonary vein isolation for atrial fibrillation using duty-cycled phased radiofrequency ablation
    Deneke, T.
    Buenz, K.
    Bastian, A.
    Haberkorn, R.
    Reinartz, B.
    Paesler, M.
    Pinger, S.
    Hoppe, C.
    Anders, H.
    Shin, D. -I.
    EUROPEAN HEART JOURNAL, 2010, 31 : 552 - 552
  • [23] Ablation of paroxysmal and persistent atrial fibrillation with multielectrode phased radiofrequency duty-cycled catheters: long-term results from a large cohort of patients
    Nardi, Stefano
    Argenziano, Luigi
    Cappato, Riccardo
    de Martino, Giuseppe
    Esposito, Cristina
    Scaglione, Mariano
    Borrello, Francesco
    Maglia, Giampiero
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2013, 14 (12) : 879 - 885
  • [24] Utility of Esophageal Temperature Monitoring During Pulmonary Vein Isolation for Atrial Fibrillation Using Duty-Cycled Phased Radiofrequency Ablation
    Deneke, Thomas
    Buenz, Kathrin
    Bastian, Annely
    Paesler, Marcus
    Anders, Helge
    Lehmann, Rainer
    Meuser, Wolfgang
    de Groot, Joris R.
    Horlitz, Marc
    Haberkorn, Ron
    Muegge, Andreas
    Shin, Dong-In
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 (03) : 255 - 261
  • [25] Characterization of reconduction of pulmonary veins after pulmonary vein isolation using a multi-electrode duty cycled radiofrequency ablation catheter
    Langbein, A.
    Karolyi, L.
    Weinmann, T.
    Scharfe, F.
    Spitzer, S. G.
    EUROPEAN HEART JOURNAL, 2015, 36 : 575 - 575
  • [26] Duty-cycled multi-electrode radiofrequency vs. conventional irrigated point-by-point radiofrequency ablation for recurrent atrial fibrillation: comparative 3-year data
    De Greef, Y.
    Buysschaert, I.
    Schwagten, B.
    Stockman, D.
    Tavernier, R.
    Duytschaever, M.
    EUROPACE, 2014, 16 (06): : 820 - 825
  • [27] Efficacy and safety of cryoballoon pulmonary vein isolation for paroxysmal and persistent atrial fibrillation: A comparison with radiofrequency ablation
    Choi, Ji-Hoon
    Park, Seung-Jung
    Park, Kyoung-Min
    Kim, June Soo
    On, Young Keun
    PLOS ONE, 2022, 17 (07):
  • [28] Voltage analysis after multi-electrode ablation with duty-cycled bipolar and unipolar radiofrequency energy: a case report
    Boersma, Lucas
    Mulder, Anton
    Jansen, Ward
    Wever, Eric
    Wijffels, Maurits
    EUROPACE, 2009, 11 (11): : 1546 - 1548
  • [29] Pulmonary vein re-isolation for atrial fibrillation using duty-cycled phased radiofrequency ablation: safety and efficacy of a primary 2:1 bipolar/unipolar ablation mode
    Wieczorek, Marcus
    Hoeltgen, Reinhard
    Tajtaraghi, Shahram
    Lawrenz, Wolfgang
    Lukat, Michael
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2013, 36 (01) : 55 - 60
  • [30] Pulmonary vein re-isolation for atrial fibrillation using duty-cycled phased radiofrequency ablation: safety and efficacy of a primary 2:1 bipolar/unipolar ablation mode
    Marcus Wieczorek
    Reinhard Hoeltgen
    Shahram Tajtaraghi
    Wolfgang Lawrenz
    Michael Lukat
    Journal of Interventional Cardiac Electrophysiology, 2013, 36 : 55 - 60