Efficacy of multi-electrode duty-cycled radiofrequency ablation for pulmonary vein disconnection in patients with paroxysmal and persistent atrial fibrillation

被引:48
|
作者
Beukema, Rypko P. [1 ]
Beukema, Willem P. [1 ]
Smit, Jaap Jan J. [1 ]
Misier, Anand R. Ramdat [1 ]
Delnoij, Peter Paul H. M. [1 ]
Wellens, Hein [1 ]
Elvan, Arif [1 ]
机构
[1] Isala Klin, Dept Cardiol, NL-8011 JW Zwolle, Netherlands
来源
EUROPACE | 2010年 / 12卷 / 04期
关键词
Atrial fibrillation; Multi-electrode ablation; Pulmonary vein isolation; CATHETER;
D O I
10.1093/europace/euq023
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim A novel multi-electrode pulmonary vein ablation catheter (PVAC) combining circular mapping and duty-cycled multi-electrode radiofrequency (RF) energy delivery has been developed to map and isolate the pulmonary veins (PVs). The aim of this study was to assess the efficacy of multi-electrode RF ablation using the PVAC device. Methods and results A total of 102 consecutive patients, age 57.9 +/- 9.6 years, with paroxysmal or persistent drug refractory atrial fibrillation (AF) were referred for ablation. All patients had documented AF episodes with an AF duration of 9.3 +/- 7.5 years (range 1.5-25). The mean total procedure time was 139.30 +/- 37.72 (median 135, range 115-172). The mean fluoroscopy time required for PVAC ablation was 17 +/- 12 min (median 16, range 12-33) and the total fluoroscopy time was 32.1 +/- 11.3 min (median 29, range 25-39). The mean multi-electrode RF ablation time required to achieve complete PV isolation was 31 +/- 6.7 min (range 16-51). In eight patients with persistent AF, additional ablations were performed to defragment septal and posterior part of the left atrium. In five patients additional RF ablations using conventional catheters were necessary. After multi-electrode duty-cycled RF ablation, 62 of 102 (60.8%) patients were in sustained sinus rhythm without anti-arrhythmic drugs. The mean follow-up duration was 12.2 +/- 3.9 months (range 6-15). Conclusion This novel multi-electrode ablation technique can be used for PV isolation and left atrium ablation with a relatively low medium-term success rate after the first ablation of similar to 61%. Larger studies with longer follow-up are required to evaluate the efficacy and whether multi-electrode RF ablation is associated with a different complication rate compared with standard PV isolation.
引用
收藏
页码:502 / 507
页数:6
相关论文
共 50 条
  • [1] Efficacy of multi-electrode duty-cycled radiofrequency ablation in patients with paroxysmal and persistent atrial fibrillation
    Kozluk, Edward
    Balsam, Pawel
    Peller, Michal
    Kiliszek, Marek
    Lodzinski, Piotr
    Piatkowska, Agnieszka
    Malkowska, Sylwia
    Rodkiewicz, Dariusz
    Kochanowski, Janusz
    Opolski, Grzegorz
    CARDIOLOGY JOURNAL, 2013, 20 (06) : 618 - 625
  • [2] Validation of PV isolation of multi-electrode duty cycled radiofrequency ablation in patients with paroxysmal and persistent atrial fibrillation
    Elvan, A.
    Beukema, W. P.
    Smit, J. J. J.
    Delnoy, P. P. H. M.
    Misier, A. R. Ramdat
    EUROPEAN HEART JOURNAL, 2009, 30 : 273 - 273
  • [3] Duty-cycled, unipolar-bipolar RF ablation via multi-electrode catheter in patients with paroxysmal atrial fibrillation
    Yuan, S.
    Kongstad, O.
    EUROPEAN HEART JOURNAL, 2009, 30 : 270 - 270
  • [4] Duty-cycled unipolar/bipolar versus conventional radiofrequency ablation in paroxysmal and persistent atrial fibrillation
    Tivig, Christine
    Dang, Lam
    Brunner-La Rocca, Hans-Peter
    Oezcan, Sibel
    Duru, Firat
    Scharf, Christoph
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 157 (02) : 185 - 191
  • [5] Pulmonary vein isolation for persistent atrial fibrillation using a novel gold multi-electrode duty cycled radiofrequency ablation catheter, first results
    Spitzer, S. G.
    Langbein, A.
    Raemmler, C.
    Scharfe, F.
    Weinmann, T.
    Otto, T.
    Karolyi, L.
    EUROPEAN HEART JOURNAL, 2015, 36 : 730 - 730
  • [6] Conduction recovery in patients with recurrent atrial fibrillation after pulmonary vein isolation using multi-electrode duty cycled radiofrequency ablation
    J. C. Balt
    S. Karadavut
    A. A. W. Mulder
    J. G. L. M. Luermans
    M. C. E. F. Wijffels
    L. V. A. Boersma
    Journal of Interventional Cardiac Electrophysiology, 2013, 37 : 197 - 204
  • [7] Conduction recovery in patients with recurrent atrial fibrillation after pulmonary vein isolation using multi-electrode duty cycled radiofrequency ablation
    Balt, J. C.
    Karadavut, S.
    Mulder, A. A. W.
    Luermans, J. G. L. M.
    Wijffels, M. C. E. F.
    Boersma, L. V. A.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2013, 37 (02) : 197 - 204
  • [8] The Use of the Multi-Electrode Duty-Cycled Radiofrequency Ablation Catheter PVAC for the Ablation of a Left Atrial Tachycardia
    Leftheriotis, Dionyssios
    Flevari, Panayota
    Simeonidou, Eftihia
    Niokou, Dimitra
    Anastasiou-Nana, Maria
    HELLENIC JOURNAL OF CARDIOLOGY, 2012, 53 (02) : 163 - 167
  • [9] European survey on efficacy and safety of duty-cycled radiofrequency ablation for atrial fibrillation
    Scharf, C.
    Ng, G. A.
    Wieczorek, M.
    Deneke, T.
    Furniss, S. S.
    Murray, St.
    Debruyne, Ph.
    Hobson, N.
    Berntsen, R. F.
    Schneider, M. A.
    Hauer, H. A.
    Halimi, F.
    Boveda, S.
    Asbach, S.
    Boesche, L.
    Zimmermann, M.
    Brigadeau, F.
    Taieb, J.
    Merkel, M.
    Pfyffer, M.
    Brunner-La Rocca, H. P.
    Boersma, L. V. A.
    EUROPACE, 2012, 14 (12): : 1700 - 1707
  • [10] Pulmonary vein isolation to treat paroxysmal atrial fibrillation: conventional versus multi-electrode radiofrequency ablation
    Rypko J. Beukema
    Arif Elvan
    Jaap Jan J. Smit
    Peter Paul H. M. Delnoy
    Anand R. Ramdat Misier
    Vivek Reddy
    Journal of Interventional Cardiac Electrophysiology, 2012, 34 : 143 - 152