Electrochemical determination of sparfloxacin in pharmaceutical formulations and urine samples using a β-cyclodextrin modified carbon paste electrode

被引:19
|
作者
Reddy, TM [1 ]
Sreedhar, M [1 ]
Reddy, SJ [1 ]
机构
[1] Sri Venkateswara Univ, Dept Chem, Electrochem Res Labs, Tirupati 517502, Andhra Pradesh, India
关键词
sparfloxacin; beta-cyclodextrin modified carbon paste electrode; urine; spectrophotometry;
D O I
10.1081/AL-120021092
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical behavior of Sparfloxacin at beta-cyclodextrin modified carbon paste electrode (CDMCPE) has been studied. Compared with bare carbon paste electrode (CPE), the beta-cyclodextrin modified carbon paste electrode exhibited a marked enhancement of current response of Sparfloxacin. Cyclic voltarnmetric (CV) studies indicate that the process was irreversible and adsorption controlled. To obtain a good sensitivity, the instrumental and accumulation variables were studied using Differential Pulse Voltammetry (DPV). A linear calibration plot was obtained over the 0.043-60 muM range with a correlation coefficient of 0.999 in pH 3.0 Britton Robinson buffer with a detection limit of 0.04 muM by using DPV. The peaks from the techniques CV and DPV are attributed to the complex formation of quinone group of the drug with P-cyclodextrin. The repeatability and reproducibility of the methods were within 7.52, 7.68% RSD for peak currents and 0.52, 0.60% RSD for peak potentials using CDMCPE. Quantitative analysis was performed by the standard addition method for Sparfloxacin in both urine and available pharmaceutical formulations. A spectrophotometric method was used as a reference method to assess the accuracy. Results obtained through spectrophotometric method were comparable to those obtained by CDMCPE.
引用
收藏
页码:1365 / 1379
页数:15
相关论文
共 50 条
  • [21] Electrochemical Behavior of the Antibiotic Minocycline and its Voltammetric Determination in Pharmaceutical Formulations at Carbon Paste Electrode
    Souza, M. R. S.
    Aragao, D. M.
    Santos, R. H. T.
    Garcia, C. A. B.
    Alves, J. P. H.
    Arguelho, M. L. P. M.
    18 SIMPOSIO BRASILEIRO DE ELETROQUIMICA E ELETROANALITICA (XVIII SIBEE), 2012, 43 (01): : 289 - 296
  • [22] Electrochemical Determination of Metronidazole in Tablet Samples Using Carbon Paste Electrode
    Nikodimos, Yosef
    Amare, Meareg
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2016, 2016
  • [23] Apple-modified carbon paste electrode: A biosensor for selective determination of dopamine in pharmaceutical formulations
    Raoof, JB
    Ojani, R
    Kiani, A
    BULLETIN OF ELECTROCHEMISTRY, 2005, 21 (05): : 223 - 228
  • [24] Highly sensitive simultaneous electrochemical determination of reduced and oxidized glutathione in urine samples using antimony trioxide modified carbon paste electrode
    Stojanovic, Zorica S.
    Durovic, Ana D.
    Ashrafi, Amir M.
    Koudelkova, Zuzana
    Zitka, Ondrej
    Richtera, Lukas
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 318
  • [25] Polymer Modified Carbon Paste Electrode as a Sensitive Sensor for the Electrochemical Determination of Riboflavin and Its Application in Pharmaceutical and Biological Samples
    D'Souza, Edwin S.
    Manjunatha, J. G.
    Raril, C.
    Tigari, Girish
    Pushpanjali, P. A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2020, 7 (04): : 461 - 472
  • [26] Determination of Diazinon in fruit samples using electrochemical sensor based on carbon nanotubes modified carbon paste electrode
    Zahirifar, Fatemeh
    Rahimnejad, Mostafa
    Abdulkareem, Rafid A.
    Najafpour, Ghasem
    BIOCATALYSIS AND AGRICULTURAL BIOTECHNOLOGY, 2019, 20
  • [27] Voltammetric behavior of some fluorinated quinolone antibacterial agents and their differential pulse voltammetric determination in drug formulations and urine samples using a β-cyclodextrin-modified carbon-paste electrode
    Reddy, T. Madhusudana
    Balaji, K.
    Reddy, S. Jayarama
    JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 62 (02) : 168 - 175
  • [28] Voltammetric behavior of some fluorinated quinolone antibacterial agents and their differential pulse voltammetric determination in drug formulations and urine samples using a β-cyclodextrin-modified carbon-paste electrode
    T. Madhusudana Reddy
    K. Balaji
    S. Jayarama Reddy
    Journal of Analytical Chemistry, 2007, 62 : 168 - 175
  • [29] Electrocatalytic determination of captopril using a modified carbon nanotube paste electrode: Application to determination of captopril in pharmaceutical and biological samples
    Beitollahi, Hadi
    Taher, Mohammad Ali
    Ahmadipour, Malihe
    Hosseinzadeh, Rahman
    MEASUREMENT, 2014, 47 : 770 - 776
  • [30] Selective electrochemical determination of uric acid in the presence of ascorbic acid using a carbon paste electrode modified with β-cyclodextrin
    Ramirez-Berriozabal, Minerva
    Galicia, Laura
    Gutierrez-Granados, Silvia
    Cortes, Jose Sandoval
    Herrasti, Pilar
    ELECTROANALYSIS, 2008, 20 (15) : 1678 - 1683