Comparison between a laser lancing device and lancet for capillary blood sampling, capillary blood hemoglobin measurement, and blood typing

被引:4
|
作者
Kim, Jeeyong [1 ]
Yoon, Soo-Young [1 ]
Lim, Chae Seung [1 ]
Yoon, Jung [1 ]
机构
[1] Korea Univ Seoul, Dept Lab Med, Coll Med, Seoul, South Korea
关键词
capillary blood sampling; donor screening; hemoglobin; lancet; laser; pain; NEEDLE; DONORS;
D O I
10.1111/trf.16582
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Blood donor screening includes tests using capillary blood, which is usually obtained by finger pricking using a lancet; however, the lancet has some shortcomings, such as skin puncture pain and needle stick injury. Recently, laser lancing devices for finger-prick sampling have been developed. We compared capillary blood Hb (cHb) levels and blood typing results obtained using a laser lancing device with those obtained using a lancet. Study design and methods cHb levels, blood typing results, and skin puncture pain scores were assessed in 191 participants. Finger-prick sampling was performed using LMT-1000 (LaMeditech, Seoul, Korea) and a lancet on the same finger on different hands. Paired venous Hb (vHb) levels were assessed in 103 participants using an automated hematology analyzer and compared with the cHb levels obtained using both lancing devices. Results The paired cHb results obtained with the laser lancing device and lancet showed a strong correlation (r = 0.927, p < .001) without any significant difference (p = .113) and a substantial agreement (kappa = 0.654) for the identification of participants with a low Hb level (<12.5 g/dl). cHb levels were significantly higher than vHb levels with both lancing devices (mean differences: 0.27-0.43 g/dl). The results of blood typing using the laser lancing device showed 100% accuracy. Use of the laser lancing device showed significantly lower skin puncture pain scores (p < .001). Conclusion Use of a laser lancing device for capillary Hb measurement and blood typing showed accurate results, with significantly reduced skin puncture pain. Laser lancing devices could be feasible for donor screening tests.
引用
收藏
页码:2918 / 2924
页数:7
相关论文
共 50 条
  • [21] Drops of Capillary Blood Are Not Appropriate for Hemoglobin Measurement with Point-of-Care Devices: A Comparative Study Using Drop Capillary, Pooled Capillary, and Venous Blood Samples
    De la Cruz-Gongora, Vanessa
    Mendez-Gomez-Humaran, Ignacio
    Berenice Gaona-Pineda, Elsa
    Shamah-Levy, Teresa
    Dary, Omar
    NUTRIENTS, 2022, 14 (24)
  • [22] THE RELATIONSHIP BETWEEN BLOOD GLYCOSYLATED HEMOGLOBIN AND HOME CAPILLARY BLOOD-GLUCOSE LEVELS IN DIABETICS
    PAISEY, RB
    MACFARLANE, DG
    SHERRIFF, RJ
    HARTOG, M
    SLADE, RR
    WHITE, DAJ
    DIABETOLOGIA, 1980, 19 (01) : 31 - 34
  • [23] Measurement of triglycerides in capillary blood: validation against whole blood measurement
    Alegria Barrero, Ana
    Cordero Fort, Alberto
    Moreno Arribas, Jose
    Rodriguez Manero, Moises
    Alegria Ezquerra, Eduardo
    MEDICINA CLINICA, 2009, 133 (10): : 375 - 378
  • [24] MEASUREMENT OF PERIFOVEAL CAPILLARY BLOOD VELOCITY WITH A SCANNING LASER OPHTHALMOSCOPE
    FRAMBACH, DA
    PAYSSE, EA
    WATERHOUSE, WJ
    CHONG, LP
    LIGGETT, PE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 691 - 691
  • [25] Capillary blood volume and pain intensity depend on lancet penetration
    Fruhstorfer, H
    Schmelzeisen-Redeker, G
    Weiss, T
    DIABETES CARE, 2000, 23 (04) : 562 - 562
  • [26] The capillary blood rheological measurement system
    Zhou, Mu
    Zhu, Lianqing
    Dong, Mingli
    SEVENTH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2011, 8321
  • [27] Whole blood cytokine release assays reveal disparity between capillary blood sampling methods
    Meredith, Rhys T.
    Yarham, Ross A. R.
    Mills, Hayley
    Oliver, Maria A.
    CLINICAL BIOCHEMISTRY, 2023, 120
  • [28] Efficacy of laser-based capillary blood sampling in anemia screening
    Randolph, SM
    Waltman, E
    Costello, DJ
    TRANSFUSION, 2004, 44 (09) : 80A - 80A
  • [29] Analysis of pain and blood volume in capillary blood sampling on finger and arm
    Park, Mi Sook
    Park, Kyung Soon
    Jun, Myung Hee
    Kim, Tae Im
    Kim, Kyung Ah
    Lee, Tae Soo
    Cha, Eun Jong
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 2520 - 2522
  • [30] Capillary blood sampling: Should the heel be warmed?
    Dunn, PM
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1996, 75 (02): : F143 - F144