Comparison between a laser lancing device and lancet for capillary blood sampling, capillary blood hemoglobin measurement, and blood typing

被引:4
|
作者
Kim, Jeeyong [1 ]
Yoon, Soo-Young [1 ]
Lim, Chae Seung [1 ]
Yoon, Jung [1 ]
机构
[1] Korea Univ Seoul, Dept Lab Med, Coll Med, Seoul, South Korea
关键词
capillary blood sampling; donor screening; hemoglobin; lancet; laser; pain; NEEDLE; DONORS;
D O I
10.1111/trf.16582
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Blood donor screening includes tests using capillary blood, which is usually obtained by finger pricking using a lancet; however, the lancet has some shortcomings, such as skin puncture pain and needle stick injury. Recently, laser lancing devices for finger-prick sampling have been developed. We compared capillary blood Hb (cHb) levels and blood typing results obtained using a laser lancing device with those obtained using a lancet. Study design and methods cHb levels, blood typing results, and skin puncture pain scores were assessed in 191 participants. Finger-prick sampling was performed using LMT-1000 (LaMeditech, Seoul, Korea) and a lancet on the same finger on different hands. Paired venous Hb (vHb) levels were assessed in 103 participants using an automated hematology analyzer and compared with the cHb levels obtained using both lancing devices. Results The paired cHb results obtained with the laser lancing device and lancet showed a strong correlation (r = 0.927, p < .001) without any significant difference (p = .113) and a substantial agreement (kappa = 0.654) for the identification of participants with a low Hb level (<12.5 g/dl). cHb levels were significantly higher than vHb levels with both lancing devices (mean differences: 0.27-0.43 g/dl). The results of blood typing using the laser lancing device showed 100% accuracy. Use of the laser lancing device showed significantly lower skin puncture pain scores (p < .001). Conclusion Use of a laser lancing device for capillary Hb measurement and blood typing showed accurate results, with significantly reduced skin puncture pain. Laser lancing devices could be feasible for donor screening tests.
引用
收藏
页码:2918 / 2924
页数:7
相关论文
共 50 条
  • [1] Capillary blood sampling: relation between lancet diameter, lancing pain and blood volume
    Fruhstorfer, H
    Schmelzeisen-Redeker, G
    Weiss, T
    EUROPEAN JOURNAL OF PAIN, 1999, 3 (03) : 283 - 286
  • [2] Comparison between a laser-lancing device and automatic incision lancet for capillary blood sampling from the heel of newborn infants: a randomized feasibility trial
    Yun, Chul Kyu
    Choi, Eui Kyung
    Kim, Hyung Jin
    Kim, Jaeyoung
    Park, Byung Cheol
    Park, Kyuhee
    Choi, Byung Min
    JOURNAL OF PERINATOLOGY, 2024, 44 (08) : 1193 - 1195
  • [3] Capillary blood sampling: relation between lancet diameter, lancing pain and blood volume (vol 3, pg 283, 1998)
    Fruhstorfer, H
    Schmelzeisen-Redeker, G
    Weiss, T
    EUROPEAN JOURNAL OF PAIN-LONDON, 1999, 3 (04): : 421 - 421
  • [4] AUTOMATIC LANCET FOR CAPILLARY BLOOD-SAMPLING
    TURNER, RC
    HOLMAN, RR
    LANCET, 1978, 2 (8092): : 712 - 712
  • [5] Biochemical and Pain Comparisons Between the Laser Lancing Device and Needle Lancets for Capillary Blood Sampling: A Randomized Control Trial
    Yoo, Won Sang
    Min, Junwon
    Chung, Phil-Sang
    Woo, Seung Hoon
    LASERS IN SURGERY AND MEDICINE, 2021, 53 (03) : 316 - 323
  • [6] HEMOGLOBIN MEASUREMENT IN CAPILLARY BLOOD WITH THE HEMATOFLUOROMETER
    SCHIFMAN, RB
    ANGEL, E
    LAMOLA, A
    RIVERS, SL
    CLINICAL CHEMISTRY, 1983, 29 (06) : 1284 - 1284
  • [7] Comparison of laser and traditional lancing devices for capillary blood sampling in patients with diabetes mellitus and high bleeding risk
    Park, Min Jeong
    Hwang, Soon Young
    Jang, Ahreum
    Jang, Soo Yeon
    Song, Eyun
    Park, So Young
    Lee, Da Young
    Kim, Jaeyoung
    Park, Byung Cheol
    Yu, Ji Hee
    Seo, Ji A.
    Choi, Kyung Mook
    Baik, Sei Hyun
    Yoo, Hye Jin
    Kim, Nan Hee
    LASERS IN MEDICAL SCIENCE, 2024, 39 (01)
  • [8] Capillary blood sampling: the pain of single-use lancing devices
    Fruhstorfer, H
    EUROPEAN JOURNAL OF PAIN-LONDON, 2000, 4 (03): : 301 - 305
  • [9] COMPARISON OF CAPILLARY EAR BLOOD AND ARTERIAL BLOOD TO VALIDATE CAPILLARY SAMPLING AS AN ACCURATE ASSAY OF BLOOD-GAS IN SWINE
    WHITE, RD
    HOOPES, KH
    ALLEN, SD
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 1979, 40 (07) : 1022 - 1024
  • [10] BLOOD SAMPLING VENOUS VERSUS CAPILLARY BLOOD
    GLADTKE, E
    ENZYMOLOGIA BIOLOGICA ET CLINICA, 1966, 6 (03) : 197 - &