Evaluation of stenosis severity of coronary calcified lesions using transluminal attenuation gradient: clinical application of 320-row volume CT

被引:3
|
作者
Yang, Fengfeng [1 ]
Dong, Jie [2 ]
Wang, Wei [3 ]
Wang, Xiuting [1 ]
Fu, Xiaojiao [1 ]
Kumar, Nanda C. [1 ]
Zhang, Tong [1 ]
机构
[1] Harbin Med Univ, Affiliated Hosp 4, Dept Radiol, Harbin 150001, Peoples R China
[2] Harbin Med Univ, Affiliated Hosp 1, Dept Geriatr, Harbin, Peoples R China
[3] Harbin Med Univ, Affiliated Hosp 1, Dept Magnet Resonance Imaging, Harbin, Peoples R China
关键词
X-ray computed tomography; Angiography; Coronary stenosis; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; FRACTIONAL FLOW RESERVE; ARTERY STENOSIS; DIAGNOSTIC PERFORMANCE; RECLASSIFICATION; EXPERIENCE; OUTCOMES; DISEASE;
D O I
10.23736/S0026-4806.17.04862-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: The aim of this study was to evaluate the accuracy of transluminal attenuation gradient (TAG) in diagnosing the stenosis degree of difficult lesions to accurately assess the degree of luminal stenosis using coronary computed tomography angiography (CCTA). METHODS: A total of 130 patients consecutively received CCTA and coronary angiography (CAG). The average transluminal Hounsfield units (HU) of the regions of interest were consecutively measured at an interval of 5 mm from the ostium to the distal level, followed by the calculation of TAG. The diagnostic performance of CCTA, TAG and CCTA+TAG for the stenosis degree of coronary calcified lesions and their reclassification for stenosis degree were analyzed, especially for calcified lesions. RESULTS: Compared with CAG, the TAG in CCTA was consistent with the largest stenosis degree of each blood vessel. TAG improved the accuracy of CCTA in the diagnosis of calcified lesions (P<0.0001). When threshold was <=-6.9 HU/10 mm, the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of CCTA+TAG in the diagnosis of coronary calcified lesions were 90.26%, 95.45%, 98.58% and 73.68%. TAG for calcified lesions had moderate sensitivity (86.61%; 95% CI: 81.8-90.5%) and high specificity (91.20%; 95% CI: 84.8-95.5%). In addition, TAG can help to improve the reclassification of CCTA for coronary stenosis degree, especially for calcified lesions (NRI=0.127, P= 0.045). CONCLUSIONS: TAG can help to improve the diagnostic performance of CCTA for the stenosis degree of lesions, and it may also help to improve the reclassification of the stenosis degree of calcified lesions.
引用
收藏
页码:305 / 316
页数:12
相关论文
共 50 条
  • [31] Application of Low Tube Voltage, Low-concentration Contrast Agent Using a 320-row CT in Coronary CT Angiography: Evaluation of Image Quality, Radiation Dose and Iodine Intake
    Pan, Yue-ying
    Zhou, Shu-chang
    Wang, Yu-jin
    Li, Qian
    Zhu, Ting-ting
    Liu, Chun-xia
    Guan, Han-xiong
    CURRENT MEDICAL SCIENCE, 2020, 40 (01) : 178 - 183
  • [32] Application of Low Tube Voltage, Low-concentration Contrast Agent Using a 320-row CT in Coronary CT Angiography: Evaluation of Image Quality, Radiation Dose and Iodine Intake
    Yue-ying Pan
    Shu-chang Zhou
    Yu-jin Wang
    Qian Li
    Ting-ting Zhu
    Chun-xia Liu
    Han-xiong Guan
    Current Medical Science, 2020, 40 : 178 - 183
  • [33] Intracoronary Transluminal Attenuation Gradient in Coronary CT Angiography for Determining Coronary Artery Stenosis (vol 4, pg 1149, 2011)
    Choi, J-H
    Min, J. K.
    Labounty, T. M.
    JACC-CARDIOVASCULAR IMAGING, 2012, 5 (01) : 129 - 129
  • [34] Adaptive Iterative Dose Reduction in coronary CT angiography using 320-row CT: Assessment of radiation dose reduction and image quality
    Tomizawa, Nobuo
    Nojo, Takeshi
    Akahane, Masaaki
    Torigoe, Rumiko
    Kiryu, Shigeru
    Ohtomo, Kuni
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (05) : 318 - 324
  • [35] 320-row CT coronary angiography: effect of 100-kV tube voltages on image quality, contrast volume, and radiation dose
    Chuanchen Zhang
    Zhaoqi Zhang
    Zixu Yan
    Lei Xu
    Wei Yu
    Rui Wang
    The International Journal of Cardiovascular Imaging, 2011, 27 : 1059 - 1068
  • [36] 320-row CT coronary angiography: effect of 100-kV tube voltages on image quality, contrast volume, and radiation dose
    Zhang, Chuanchen
    Zhang, Zhaoqi
    Yan, Zixu
    Xu, Lei
    Yu, Wei
    Wang, Rui
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (07): : 1059 - 1068
  • [37] Does vessel length impact transluminal attenuation gradient in 320-slice coronary CT angiography? Correlation with invasive angiography
    Xu, Nan
    Peng, Kun
    Dai, Shun
    Zhang, Lei
    Yu, Hong
    Dai, Gonghua
    Jin, Liqing
    Hu, Bo
    Tang, Guangyu
    EUROPEAN RADIOLOGY, 2019, 29 (12) : 6837 - 6845
  • [38] Does vessel length impact transluminal attenuation gradient in 320-slice coronary CT angiography? Correlation with invasive angiography
    Nan Xu
    Kun Peng
    Shun Dai
    Lei Zhang
    Hong Yu
    Gonghua Dai
    Liqing Jin
    Bo Hu
    Guangyu Tang
    European Radiology, 2019, 29 : 6837 - 6845
  • [39] Low contrast and radiation dose coronary CT angiography using a 320-row system and a refined contrast injection and timing method
    Oda, Seitaro
    Utsunomiya, Daisuke
    Yuki, Hideaki
    Kai, Noriyuki
    Hatemura, Masahiro
    Funama, Yoshinori
    Kidoh, Masafumi
    Yoshida, Morikatsu
    Namimoto, Tomohiro
    Yamashita, Yasuyuki
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2015, 9 (01) : 19 - 27
  • [40] Assessment of Coronary Artery Aneurysms Caused by Kawasaki Disease Using Transluminal Attenuation Gradient Analysis of Coronary CT Angiograms
    Gutierrez, Noelia Grande
    Shirinsky, Olga
    Gagarina, Nina V.
    Lyskina, Galina A.
    Fukazawa, Ryuji
    Ogawa, Shunichi
    Burns, Jane C.
    Marsden, Alison L.
    Kahn, Andrew M.
    CIRCULATION, 2015, 132