Endoleaks after endovascular aortic aneurysm repair: Improved detection with noise-optimized virtual monoenergetic dual-energy CT

被引:39
|
作者
Martin, Simon S. [1 ]
Wichmann, Julian L. [1 ]
Weyer, Hendrik [1 ]
Scholtz, Jan-Erik [1 ,2 ]
Leithner, Doris [1 ]
Spandorfer, Adam [3 ]
Bodelle, Boris [1 ]
Jacobi, Volkmar [1 ]
Vogl, Thomas J. [1 ]
Albrecht, Moritz H. [1 ,3 ]
机构
[1] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Theodor Stern Kai 7, D-60590 Frankfurt, Germany
[2] Harvard Med Sch, Massachusetts Gen Hosp, Cardiac MR PET CT Program, Boston, MA USA
[3] Med Univ South Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
关键词
Endoleak; Diagnostic performance; Monoenergetic imaging; Vascular imaging; KILOELECTRON-VOLT-SETTINGS; COMPUTED-TOMOGRAPHY; NECK-CANCER; ANGIOGRAPHY; CONTRAST; PHASE; REDUCTION; IMAGES; EVAR; HEAD;
D O I
10.1016/j.ejrad.2017.06.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess image quality and diagnostic performance of a noise-optimized algorithm to reconstruct virtual monoenergetic images (VMI+) for the detection of endoleaks after endovascular abdominal aortic aneurysm repair (EVAR) using dual-energy CT angiography (DE-CTA). Materials and methods: Seventy-five patients (42 men; 66.2 +/- 11.7 years) underwent DE-CTA following EVAR. Arterial phase images were acquired in dual-energy mode for the reconstruction of standard linearly-blended M 0.5, VMI+ and traditional monoenergetic images (VMI) at 40-100 keV in 10-keV intervals. Contrast-to-noise ratios (CNR) were calculated for the area of leakage in patients with endoleaks. Diagnostic accuracy for endoleak detection was evaluated by three blinded radiologists using the objectively best series for each reconstruction technique. Results: Thirty-four out of 75 patients showed endoleaks. Quantitative image parameters were highest at 40-keV VMI+ (CNR, 21.3 +/- 11.1), compared to M 0.5 (CNR, 10.9 +/- 5.5) and all VMI series that showed highest values at 70 keV (CNR, 13.5 +/- 6.6; all P < 0.001). ROC analysis for endoleak detection revealed an area under the curve (AUC) of 0.992 for 40-keV VMI+ series, which was significantly higher (P <= 0.039) compared to 70keV VMI (0.914) and M 0.5 series (0.916). Conclusions: Noise-optimized VMI+ series at 40 keV improve diagnostic accuracy for the detection and rule-out of endoleaks after EVAR.
引用
收藏
页码:125 / 132
页数:8
相关论文
共 50 条
  • [1] Endoleaks after Endovascular Abdominal Aortic Aneurysm Repair: Detection with Dual-Energy Dual-Source CT
    Stolzmann, Paul
    Frauenfelder, Thomas
    Pfammatter, Thomas
    Peter, Nicole
    Scheffel, Hans
    Lachat, Mario
    Schmidt, Bernhard
    Marincek, Borut
    Alkadhi, Hatem
    Schertler, Thomas
    RADIOLOGY, 2008, 249 (02) : 682 - 691
  • [2] Value of a noise-optimized virtual monoenergetic reconstruction technique in dual-energy CT for planning of transcatheter aortic valve replacement
    Simon S. Martin
    Moritz H. Albrecht
    Julian L. Wichmann
    Kristina Hüsers
    Jan-Erik Scholtz
    Christian Booz
    Boris Bodelle
    Ralf W. Bauer
    Sarah C. Metzger
    Thomas J. Vogl
    Thomas Lehnert
    European Radiology, 2017, 27 : 705 - 714
  • [3] Value of a noise-optimized virtual monoenergetic reconstruction technique in dual-energy CT for planning of transcatheter aortic valve replacement
    Martin, Simon S.
    Albrecht, Moritz H.
    Wichmann, Julian L.
    Huesers, Kristina
    Scholtz, Jan-Erik
    Booz, Christian
    Bodelle, Boris
    Bauer, Ralf W.
    Metzger, Sarah C.
    Vogl, Thomas J.
    Lehnert, Thomas
    EUROPEAN RADIOLOGY, 2017, 27 (02) : 705 - 714
  • [4] Noise-Optimized Virtual Monoenergetic Dual-Energy CT Improves Diagnostic Accuracy for the Detection of Active Arterial Bleeding of the Abdomen
    Martin, Simon S.
    Wichmann, Julian L.
    Scholtz, Jan-Erik
    Leithner, Doris
    D'Angelo, Tommaso
    Weyer, Hendrik
    Booz, Christian
    Lenga, Lukas
    Vogl, Thomas J.
    Albrecht, Moritz H.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2017, 28 (09) : 1257 - 1266
  • [5] Improved Detection of Endoleaks in Virtual Monoenergetic Images in Dual-Energy CT Angiography Following EVAR
    Kazimierczak, Wojciech
    Kazimierczak, Natalia
    Lemanowicz, Adam
    Nowak, Ewa
    Migdalski, Arkadiusz
    Jawien, Arkadiusz
    Jankowski, Tomasz
    Serafin, Zbigniew
    ACADEMIC RADIOLOGY, 2023, 30 (12) : 2813 - 2824
  • [6] Comparison of noise-optimized linearly blended images and noise-optimized virtual monoenergetic images evaluated by dual-source, dual-energy CT in cardiac vein assessment
    Kim, Gyeong Min
    Choo, Ki Seok
    Kim, Jin Hyeok
    Hwang, Jae-Yeon
    Park, Chan Kyu
    Lee, Ji Won
    Lim, Soo Jin
    ACTA RADIOLOGICA, 2021, 62 (05) : 594 - 602
  • [7] Dual-Energy CT for Detection of Endoleaks After Endovascular Abdominal Aneurysm Repair: Usefulness of Colored Iodine Overlay
    Ascenti, Giorgio
    Mazziotti, Silvio
    Lamberto, Salvatore
    Bottari, Antonio
    Caloggero, Simona
    Racchiusa, Sergio
    Mileto, Achille
    Scribano, Emanuele
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) : 1408 - 1414
  • [8] Dual-energy CT in patients with colorectal cancer: Improved assessment of hypoattenuating liver metastases using noise-optimized virtual monoenergetic imaging
    Lenga, Lukas
    Czwikla, Rouben
    Wichmann, Julian L.
    Leithner, Doris
    Albrecht, Moritz H.
    Booz, Christian
    Arendt, Christophe T.
    Yel, Ibrahim
    D'Angelo, Tommaso
    Vogl, Thomas J.
    Martin, Simon S.
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 106 : 184 - 191
  • [9] Dual-energy CT of the pancreas: improved carcinoma-to-pancreas contrast with a noise-optimized monoenergetic reconstruction algorithm
    Frellesen, Claudia
    Fessler, Freia
    Hardie, Andrew D.
    Wichmann, Julian L.
    De Cecco, Carlo N.
    Schoepf, U. Joseph
    Kerl, J. Matthias
    Schulz, Boris
    Hammerstingl, Renate
    Vogl, Thomas J.
    Bauer, Ralf W.
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (11) : 2052 - 2058
  • [10] Dual-Energy CT in the Follow-Up after Endovascular Abdominal Aortic Aneurysm Repair
    Braegelmann, A.
    Bunck, A.
    Donas, K.
    Kasprzak, B.
    Maintz, D.
    Heindel, W.
    Seifarth, H.