Endometrium imaging using real-time rotational optical coherence tomography imaging system A pilot, prospective and ex-vivo study

被引:5
|
作者
Law, Tracy Sze Man [1 ]
Wu, Fangrong [1 ]
Xu, Hui [1 ]
Wang, Chi Chiu [1 ,2 ,3 ]
Li, Tin Chiu [1 ]
机构
[1] Chinese Univ Hong Kong, Fac Med, Dept Obstet & Gynaecol, Shatin, Hong Kong, Peoples R China
[2] Chinese Univ Hong Kong, Fac Med, Li Ka Shing Inst Hlth Sci, Shatin, Hong Kong, Peoples R China
[3] Chinese Univ Hong Kong, Fac Med, Sch Biomed Sci, Shatin, Hong Kong, Peoples R China
关键词
endometrium; gynecology; optical coherence; tomography; uterus; COLPOSCOPY; AGREEMENT; ACCURACY;
D O I
10.1097/MD.0000000000017738
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study aimed to evaluate a novel real-time rotational optical coherence tomography (OCT) imaging system (OCTIS) with a fiber-optic probe to look at endometrium and to correlate the OCTIS images with standard histology. OCT could obtain real-time images resembling histological examination. With recent development of customized probes, it allows OCT to be used in the field of gynecology. This is a pilot, prospective, ex-vivo and observational study. Women underwent hysterectomy for various gynecological conditions were recruited and OCTIS images were obtained from endometrium of 15 fresh uterus specimens immediately after hysterectomy. The excised uterus was cut open and OCTIS imaging was obtained. The scanned region of endometrium was excised for histological examination and OCTIS images were precisely compared to corresponding histological images and ultrasound images. Blinded qualitative analysis on OCTIS images was performed by 2 assessors to determine inter-rating reliability on the histopathological diagnosis. Epithelium, glands, cysts, and stroma of endometrium were clearly seen by the OCTIS. Different phases of menstrual cycle of normal endometrium could be differentiated and pathological condition such as hyperplastic and dysplasic endometrium, which corresponded well with histological findings, could be identified. The inter-rater reliability between assessors on overall OCTIS endometrium and neoplastic OCTIS endometrium was moderate (Kendall tau b of 0.58) and substantial (Kendall tau b of 0.76), respectively. OCTIS can provide real-time, high-resolution and rotational imaging modality to view endometrial structure with high consistency with histological examination and satisfactory agreement between observers. It has a great potential to be developed in the clinical use of endometrial assessment for gynecological applications.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Ex vivo imaging of human thyroid pathology using integrated optical coherence tomography and optical coherence microscopy
    Zhou, Chao
    Wang, Yihong
    Aguirre, Aaron D.
    Tsai, Tsung-Han
    Cohen, David W.
    Connolly, James L.
    Fujimoto, James G.
    JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (01)
  • [32] Real-time optical coherence tomography for minimally invasive imaging of prostate ablation
    Boppart, SA
    Herrmann, JM
    Pitris, C
    Stamper, DL
    Brezinski, ME
    Fujimoto, JG
    JOURNAL OF UROLOGY, 2002, 168 (01): : 401 - 401
  • [33] Real-time imaging of transscleral diode laser cyclophotocoagulation by optical coherence tomography
    H. Hoerauf
    M. Müller
    G. Hüttmann
    C. Winter
    T. Schlote
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2007, 245 : 385 - 390
  • [34] Real-time imaging of transscleral diode laser cyclophotocoagulation by optical coherence tomography
    Hoerauf, H.
    Mueller, M.
    Huettmann, G.
    Winter, C.
    Schlote, T.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (03) : 385 - 390
  • [35] In vivo imaging of microvasculature using optical coherence tomography
    Vakoc, B. J.
    Lanning, R. M.
    Tyrrell, J. A.
    Padera, T. P.
    Bartlett, L. A.
    Stylianopoulos, T.
    Munn, L. L.
    Tearney, G. J.
    Fukumura, D.
    Jain, R. K.
    Bouma, B. E.
    2010 IEEE PHOTONICS SOCIETY WINTER TOPICALS MEETING SERIES, 2010, : 59 - 60
  • [36] Ex-vivo analysis of demineralisation on irradiated teeth using optical coherence tomography
    Saberi, Fatin Najwa Mohamad
    Liew, Yih Miin
    Sukumaran, Prema
    Ung, Ngie Min
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2023, 43
  • [37] Transscleral optical coherence tomography - An experimental study in ex-vivo human eyes
    Hoerauf, H
    Winkler, J
    Scholz, C
    Wirbelauer, C
    Gordes, RS
    Koch, P
    Engelhardt, R
    Laqua, H
    Birngruber, R
    LASERS IN SURGERY AND MEDICINE, 2002, 30 (03) : 209 - 215
  • [38] Real-time in vivo colors Doppler optical coherence tomography
    Rollins, AM
    Yazdanfar, S
    Barton, JK
    Izatt, JA
    JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (01) : 123 - 129
  • [39] Retinal imaging using adaptive optics optical coherence tomography with fast and accurate real-time tracking
    Mozaffari, Sanam
    Feroldi, Fabio
    LaRocca, Francesco
    Tiruveedhula, Pavan
    Gregory, Patrick D.
    Park, B. Hyle
    Roorda, Austin
    BIOMEDICAL OPTICS EXPRESS, 2022, 13 (11) : 5909 - 5925
  • [40] Real-time high-speed volumetric imaging using compressive sampling optical coherence tomography
    Young, Mei
    Lebed, Evgeniy
    Jian, Yifan
    Mackenzie, Paul J.
    Beg, Mirza Faisal
    Sarunic, Marinko V.
    BIOMEDICAL OPTICS EXPRESS, 2011, 2 (09): : 2690 - 2697