Retrospective Comparison of Postinsertion Maintenances Between Conventional and 3D Printed Complete Dentures Fabricated in a Predoctoral Clinic

被引:16
|
作者
Kim, Tae Hyung [1 ]
Huh, Jung Bo [2 ]
Lee, Janet [3 ]
Bae, Eun-Bin [4 ]
Park, Cheryl J. [5 ]
机构
[1] Univ Southern Calif, Removable Prosthodont, Div Restorat Sci, Herman Ostrow Sch Dent, Los Angeles, CA 90007 USA
[2] Pusan Natl Univ, Sch Dent, Inst Dent Res, Inst Translat Dent Sci,Dept Prosthodont, Yangsan, South Korea
[3] Univ Penn, Philadelphia, PA 19104 USA
[4] Pusan Natl Univ, Sch Dent, Inst Translat Dent Sci, Dept Prosthodont, Yangsan, South Korea
[5] Univ Southern Calif, Div Restorat Sci, Herman Ostrow Sch Dent, Los Angeles, CA 90007 USA
关键词
3D Printed denture; digital denture comparison; printed denture performance; ENGINEERED COMPLETE DENTURES; PERFORMANCE; IMPRESSION;
D O I
10.1111/jopr.13322
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose A retrospective study to analyze the clinical performance of 3D printed complete dentures in edentulous patients compared with conventional complete dentures regarding postinsertion visits and patient reported outcomes. Material and Methods Electronic charts were reviewed to analyze 420 (maxilla 270, mandible 150) heat-polymerized conventional complete dentures (CCD) inserted between July 1, 2015 and June 30, 2016 and 217 (maxilla 130, mandible 86) 3D printed complete dentures (PCD) inserted between July 1, 2017 and June 30, 2018. Number of remakes, number of postinsertion adjustments, type and number of repairs, and patient reported complications were compared between two types of complete dentures. The frequency of denture repair and patient reported complications were analyzed using chi-square of independence test. Results The frequency of pain and visible ulcer lesions in the maxilla was determined to be 46.67% with CCD and 36.15% in PCD (p = 0.047). There was no statistical significance in other items. The majority of esthetic concerns was dissatisfaction with the shape of dentures with CCD (4.67%) and they had statistically significant, less frequent, esthetic problems than PCD (11.63%) (p = 0.047). Conclusions Similar clinical performance was recorded between the two groups, but the overall pain and visible ulcer lesions were less in the printed complete dentures then the conventionally processed dentures. However, the esthetic aspect was better in conventionally processed complete dentures.
引用
收藏
页码:158 / 162
页数:5
相关论文
共 50 条
  • [41] Comparison between calcium carbonate and β-tricalcium phosphate as additives of 3D printed scaffolds with polylactic acid matrix
    Donate, Ricardo
    Monzon, Mario
    Ortega, Zaida
    Wang, Ling
    Ribeiro, Viviana
    Pestana, David
    Oliveira, Joaquim M.
    Reis, Rui L.
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2020, 14 (02) : 272 - 283
  • [42] Functional performance and patient satisfaction comparison between a 3D printed and a standard transradial prosthesis: a case report
    Copeland, Christopher
    Reyes, Claudia Cortes
    Peck, Jean L.
    Srivastava, Rakesh
    Zuniga, Jorge M.
    BIOMEDICAL ENGINEERING ONLINE, 2022, 21 (01)
  • [43] Functional performance and patient satisfaction comparison between a 3D printed and a standard transradial prosthesis: a case report
    Christopher Copeland
    Claudia Cortes Reyes
    Jean L. Peck
    Rakesh Srivastava
    Jorge M. Zuniga
    BioMedical Engineering OnLine, 21
  • [44] Profiling paracrine interactions between hypoxic and normoxic skeletal muscle tissue in a microphysiological system fabricated from 3D printed components
    Rexius-Hall, Megan L.
    Madrigal, Malinda D.
    Kilic, Cem Y.
    Shen, Keyue
    Mccain, Megan L.
    LAB ON A CHIP, 2025, 25 (02) : 212 - 224
  • [45] Author Correction: Structural analysis of customized 3D printed plate for pelvic bone by comparison with conventional plate based on bending process
    Woo-Lam Jo
    Yang-Guk Chung
    Seung-Han Shin
    Jae-hak Lim
    Moo-Sub Kim
    Do-Kun Yoon
    Scientific Reports, 13
  • [46] Comparison of 3D positional accuracy of implant analogs in printed resin models versus conventional stone casts: Effect of implant angulation
    Tan, Shaun
    Tan, Ming Yi
    Wong, Keng Mun
    Maria, Rahmat
    Tan, Keson Beng Choon
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (01): : 46 - 53
  • [47] Comparison between 3D delta plate and conventional miniplate in treatment of condylar fracture: A randomised clinical trial
    Ganguly, Aneesh
    Mittal, Gaurav
    Garg, Ritesh
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2021, 49 (11) : 1026 - 1034
  • [48] A Comparison of Radiographic Outcomes between 3D Preoperative Planning and Conventional Planning in the Osteosynthesis of Distal Radius Fractures
    Yoshii, Yuichi
    Totoki, Yasukazu
    Tung, Wen-lin
    Akita, Kenichi
    Ishii, Tomoo
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2019, 24 (03): : 303 - 310
  • [49] Exploration of Conventional and FDM-Mediated 3D Printed Tablets Fabricated Using HME-Based Filaments for pH-Dependent Drug Delivery
    Patil, Ruchira
    Bule, Prajakta
    Chella, Naveen
    AAPS PHARMSCITECH, 2025, 26 (04):
  • [50] Comparison of marginal and internal fit of pressed lithium disilicate veneers fabricated via a manual waxing technique versus a 3D printed technique
    Guacheta, Lizeth
    Stevens, Clinton D.
    Tamayo Cardona, Julian A.
    Murgueitio, Rafael
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2022, 34 (04) : 715 - 720