Comparison between invasive hemodynamic measurements and noninvasive assessment of left ventricular diastolic function by use of Doppler echocardiography in healthy anesthetized cats

被引:59
|
作者
Schober, KE [1 ]
Fuentes, VL
Bonagura, JD
机构
[1] Univ Missouri, Coll Vet Med, Dept Vet Med & Surg, Columbia, MO 65211 USA
[2] Univ Leipzig, Fac Med Vet, Dept Small Anim Med, D-04103 Leipzig, Germany
关键词
D O I
10.2460/ajvr.2003.64.93
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To compare Doppler echocardiographic variables of left ventricular 0) function with those obtained invasively via cardiac catheterization under a range of hemodynamic conditions. Animals-7 healthy anesthetized cats U to 3 years of age). Procedure-Cats were anesthetized and instrumented to measure the time constant of isovolumic relaxation (tau [tau]), LV end-diastolic pressure (LVEDP), peak negative and positive rate of change of LV pressure, arterial blood pressure, and cardiac output. Echocardiographic variables of diastolic function (isovolumic relaxation time [IVRT], early LV flow propagation velocity [Vp], transmitral and pulmonary venous flow velocity indices, and LV tissue Doppler imaging indices) were measured simultaneously over a range of hemodynamic states induced by treatments with esmolol, dobutamine, cilobradine, and volume loading. Correlation between invasive and noninvasive measures of LV filling was determined by univariate and multivariate regression analyses. Results-Significant correlations were found between tau and IVRT, peak Vp, peak late transmitral flow velocity, and peak systolic pulmonary venous flow velocity. A significant correlation was found between LVEDP and early diastolic transmitral flow velocity (peak E) and the ratio of peak E to peak Vp, but not between LVEDP and peak Vp. Conclusions and Clinical Relevance-IVRT and Vp can be used as noninvasive indices of LV relaxation; Vp was independent of preload and heart rate in this study. The E:Vp ratio may be useful as an indicator of LV filling pressure.
引用
收藏
页码:93 / 103
页数:11
相关论文
共 50 条
  • [31] Reference Values of Tissue Doppler Imaging and Pulsed Doppler Echocardiography for Analysis of Left Ventricular Diastolic Function in Healthy Adults
    Angelo, Lilian C.
    Vieira, Marcelo L. C.
    Rodrigues, Sergio L.
    Morelato, Renato
    Pereira, Alexandre C.
    Mill, Jose G.
    Krieger, Jose E.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2010, 27 (07): : 777 - 782
  • [32] NONINVASIVE ASSESSMENT OF LEFT-VENTRICULAR DIASTOLIC FUNCTION IN ATHLETES
    SPIRITO, P
    AGATI, L
    DERCHI, G
    PELLICCIA, A
    PENCO, M
    FABIETTI, F
    DAGIANTI, A
    VECCHIO, C
    ECHOCARDIOGRAPHY 1988, 1988, 806 : 167 - 172
  • [33] ASSESSMENT OF LEFT-VENTRICULAR DIASTOLIC FUNCTION - COMPARISON OF DOPPLER AND BLOOD POOL SCINTIGRAPHY
    FRIEDMAN, B
    DRINKOVIC, N
    MILES, H
    STIPP, V
    MAZZOLENI, A
    DEMARIA, AN
    CIRCULATION, 1985, 72 (04) : 429 - 429
  • [34] Echo-Doppler assessment of left ventricular diastolic function
    Rusconi, C
    Faggiano, P
    Sabatini, T
    Ghizzoni, G
    Oneglia, C
    Gardini, A
    Orlando, G
    JOURNAL OF CARDIOVASCULAR DIAGNOSIS AND PROCEDURES, 1996, 13 (02): : 177 - 184
  • [35] A practical guide to assessment of ventricular diastolic function using Doppler echocardiography
    Cohen, GI
    Pietrolungo, JF
    Thomas, JD
    Klein, AL
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (07) : 1753 - 1760
  • [36] First pass Tc-99m MIBI ventriculography in the assessment of left ventricular diastolic function a comparison with Doppler echocardiography
    Sharifi, M
    Khedkar, N
    Peller, P
    Martinez, C
    Sorkin, R
    Lakier, J
    CLINICAL NUCLEAR MEDICINE, 1996, 21 (09) : 679 - 684
  • [37] Comparison between the British and the American/European guidelines for the assessment of left ventricular diastolic function with invasive validation of left ventricular filling pressure
    Barakat, A.
    Alsaadi, A. R.
    EUROPEAN HEART JOURNAL, 2021, 42 : 94 - 94
  • [38] NONINVASIVE ASSESSMENT OF LEFT-VENTRICULAR DIASTOLIC FUNCTION - COMPARATIVE-ANALYSIS OF PULSED DOPPLER ULTRASOUND AND DIGITIZED M-MODE ECHOCARDIOGRAPHY
    SPIRITO, P
    MARON, BJ
    BELLOTTI, P
    CHIARELLA, F
    VECCHIO, C
    AMERICAN JOURNAL OF CARDIOLOGY, 1986, 58 (09): : 837 - 843
  • [39] Assessment of left ventricular diastolic filling in arterial hypertension - Comparison of pulsed Doppler echocardiography and acoustic quantification
    Muscholl, MW
    Kurzidim, K
    Pfeifer, M
    Blumberg, F
    Riegger, GAJ
    Elsner, D
    AMERICAN JOURNAL OF HYPERTENSION, 1998, 11 (08) : 1032 - 1036
  • [40] LEFT-VENTRICULAR DIASTOLIC FUNCTION IN IDIOPATHIC CARDIOMYOPATHY - DOPPLER HEMODYNAMIC CORRELATIONS
    LAVINE, SJ
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1991, 8 (02): : 151 - 161