Effect of imaging parameters on the accuracy of apparent diffusion coefficient and optimization strategies

被引:42
|
作者
Celik, Azim [1 ]
机构
[1] GE Healthcare, Antalya, Turkey
关键词
WEIGHTED MR; B-VALUE; PROSTATE-CANCER; BRAIN; LIVER; BODY; DIFFERENTIATION; BENIGN; TISSUE; TIME;
D O I
10.5152/dir.2015.14440
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE We aimed to investigate the effect of key imaging parameters on the accuracy of apparent diffusion coefficient (ADC) maps using a phantom model combined with ADC calculation simulation and propose strategies to improve the accuracy of ADC quantification. METHODS Diffusion-weighted imaging (DWI) sequences were acquired on a phantom model using single-shot echo-planar imaging DWI at 1.5 T scanner by varying key imaging parameters including number of averages (NEX), repetition time (TR), echo time (TE), and diffusion preparation pulses. DWI signal simulations were performed for varying TR and TE. RESULTS Magnetic resonance diffusion signal and ADC maps were dependent on TR and TE imaging parameters as well as number of diffusion preparation pulses, but not on the NEX. However, the choice of a long TR and short TE could be used to minimize their effects on the resulting DWI sequences and ADC maps. CONCLUSION This study shows that TR and TE imaging parameters affect the diffusion images and ADC maps, but their effect can be minimized by utilizing diffusion preparation pulses. Another key imaging parameter, NEX, is less relevant to DWI and ADC quantification as long as DWI signal-to-noise ratio is above a certain level. Based on the phantom results and data simulations, DWI acquisition protocol can be optimized to obtain accurate ADC maps in routine clinical application for whole body imaging.
引用
收藏
页码:101 / 107
页数:7
相关论文
共 50 条
  • [21] Application of apparent diffusion coefficient and exponent apparent diffusion coefficient values in magnetic resonance imaging diffusion-weighted imaging to differentiate benign and malignant ovarian epithelial tumors
    Wang, Yu-Xing
    Yuan, Ming-Zhi
    Wen, Zhao-Xia
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2016, 12 (01) : 401 - 405
  • [22] Dependence of apparent diffusion coefficient on slice position in magnetic resonance diffusion imaging
    Takatsu, Yasuo
    Nakamura, Masafumi
    Suzuki, Yuichi
    Miyati, Tosiaki
    MAGNETIC RESONANCE IMAGING, 2023, 99 : 41 - 47
  • [23] The value of diffusion-weighted imaging for monitoring the chemotherapeutic response of osteosarcoma: a comparison between average apparent diffusion coefficient and minimum apparent diffusion coefficient
    Oka, Kiyoshi
    Yakushiji, Toshitake
    Sato, Hiro
    Hirai, Toshinori
    Yamashita, Yasuyuki
    Mizuta, Hiroshi
    SKELETAL RADIOLOGY, 2010, 39 (02) : 141 - 146
  • [24] Diffusion-weighted MR imaging with apparent diffusion coefficient and apparent diffusion tensor maps in cervical spondylotic myelopathy
    Demir, A
    Ries, M
    Moonen, CTW
    Vital, LM
    Dehais, J
    Arne, P
    Caillé, JM
    Dousset, V
    RADIOLOGY, 2003, 229 (01) : 37 - 43
  • [25] The value of diffusion-weighted imaging for monitoring the chemotherapeutic response of osteosarcoma: a comparison between average apparent diffusion coefficient and minimum apparent diffusion coefficient
    Kiyoshi Oka
    Toshitake Yakushiji
    Hiro Sato
    Toshinori Hirai
    Yasuyuki Yamashita
    Hiroshi Mizuta
    Skeletal Radiology, 2010, 39 : 141 - 146
  • [26] The effect of hypertension on the apparent diffusion coefficient values of kidneys
    Yildirim, Erkan
    Gullu, Hakan
    Caliskan, Mustafa
    Karadeli, Elif
    Kirba, Ismail
    Muderrisoglu, Haldun
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2008, 14 (01) : 9 - 13
  • [27] Imaging parameter effects in apparent diffusion coefficient determination of magnetic resonance imaging
    Ogura, Akio
    Hayakawa, Katsumi
    Miyati, Tosiaki
    Maeda, Fumie
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 77 (01) : 185 - 188
  • [28] EFFECT OF SAMPLING ON THE ESTIMATION OF THE APPARENT COEFFICIENT OF DIFFUSION IN MRI
    Aja-Fernandez, Santiago
    Pena-Nogales, Oscar
    de Luis-Garcia, Rodrigo
    2017 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2017, : 896 - 899
  • [29] Relationships between brain water content and diffusion tensor imaging parameters (apparent diffusion coefficient and fractional anisotropy) in multiple sclerosis
    Sijens, PE
    Irwan, R
    Potze, JH
    Mostert, JP
    De Keyser, J
    Oudkerk, M
    EUROPEAN RADIOLOGY, 2006, 16 (04) : 898 - 904
  • [30] Relationships between brain water content and diffusion tensor imaging parameters (apparent diffusion coefficient and fractional anisotropy) in multiple sclerosis
    Paul E. Sijens
    Roy Irwan
    Jan Hendrik Potze
    Jop P. Mostert
    Jacques De Keyser
    Matthijs Oudkerk