Observational evaluation of outdoor cooling potential of air-source heat pump water heaters

被引:5
|
作者
Yamaguchi, Kazuki [1 ]
Ihara, Tomohiko [2 ]
Kikegawa, Yukihiro [3 ]
机构
[1] Tokyo Elect Power Co Holdings Inc, TEPCO Res Inst, Tsurumi Ku, 4-1 Egasaki Cho, Yokohama, Kanagawa 2308510, Japan
[2] Univ Tokyo, Grad Sch Frontier Sci, 5-1-5 Kashiwanoha, Kashiwa, Chiba 2770882, Japan
[3] Meisei Univ, Sch Sci & Engn, 2-1-1 Hodokubo, Hino, Tokyo 1918506, Japan
关键词
Air-source heat pump water heater; Cold exhaust; Urban heat island; Building-scale climate; Observation; ANTHROPOGENIC HEAT; URBAN CLIMATE; SLEEP STAGES; TEMPERATURE; PERFORMANCE; MITIGATION; IMPACT; ISLAND; TOKYO; MORTALITY;
D O I
10.1007/s00704-021-03673-2
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Heat pump water heaters are highly efficient hot water supply systems that effectively utilize the heat of outdoor air via heat pump technology. Many studies have been conducted to optimize the design and operation of heat pump water heaters from the perspective of climate change mitigation. Air-source heat pump water heaters, which absorb heat from the outdoor air and emit cold exhaust, can also be expected to alleviate the urban heat island effect; however, this has not been studied extensively. To estimate the impact of cold exhaust on building-scale climate, we conducted a multipoint measurement of the outdoor thermal environment around a low-rise apartment building equipped with air-source heat pump water heaters, in both summer and winter. Observations showed a substantial cooling effect that decreased air temperatures by 1 degrees C within the site boundary on summer nights when multiple heat pump water heaters operated concurrently. The analysis revealed that the sensitivity of the ambient temperatures to cold exhaust depends strongly on local atmospheric conditions. The most influential factor was the wind direction: the sensitivity increased significantly when the exhaust outlet location was at the lee side of the building. Naturally, the wind speed also affected the sensitivity, which tended to be higher when the wind speed was lower. The convective stability near the ground surface, however, showed no significant influence over the sensitivity.
引用
收藏
页码:1007 / 1025
页数:19
相关论文
共 50 条
  • [31] Performance evaluation of air-source heat pump based on a pressure drop embedded model
    Koopman, Tim
    Zhu, Tingting
    Rohlfs, Wilko
    HELIYON, 2024, 10 (04)
  • [32] New ideas on defrosting control of air-source heat pump
    Huang, XW
    Wang, RX
    Li, DY
    2ND ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, PROCEEDINGS: NEW CONTRIBUTION TO ASIAN SUSTAINABLE DEVELOPMENT, 2004, : 124 - 132
  • [33] Application and analysis of a new air-source heat pump in Beijing
    Huang, XW
    Wang, RX
    Li, DY
    2ND ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, PROCEEDINGS: NEW CONTRIBUTION TO ASIAN SUSTAINABLE DEVELOPMENT, 2004, : 282 - 289
  • [34] Experimental investigation of air-source heat pump for cold regions
    Ma, GY
    Chai, QH
    Jiang, Y
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (01): : 12 - 18
  • [35] Evaluation of the coefficient of performance of an air source heat pump unit and an air to water heat pump
    Tangwe, S.
    Kusakana, K.
    JOURNAL OF ENERGY IN SOUTHERN AFRICA, 2021, 32 (01) : 27 - 40
  • [36] A statistical methodology to compare the performance of residential air source heat pump water heaters
    Tangwe, Stephen
    Kusakana, Kanzumba
    INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2021, 40 (08) : 719 - 738
  • [37] Performance of an air-source heat pump with multi-circuit outdoor coil for continuous heating during defrosting
    Tang, Lan
    Liu, Xi 'an
    He, Shiquan
    Li, Qingjian
    JOURNAL OF BUILDING ENGINEERING, 2024, 85
  • [38] A NEW METHOD FOR PREVENTING AIR SOURCE HEAT PUMP WATER HEATERS FROM FROSTING
    Zhang, L.
    Fujinawa, T.
    Saikawa, M.
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 1637 - 1644
  • [39] Frosting Phenomenon and Frost-Free Technology of Outdoor Air Heat Exchanger for an Air-Source Heat Pump System in China: An Analysis and Review
    Zhang, Yi
    Zhang, Guanmin
    Zhang, Aiqun
    Jin, Yinhan
    Ru, Ruirui
    Tian, Maocheng
    ENERGIES, 2018, 11 (10)
  • [40] Experiment and simulation of two-stage compression air-source heat pump water heater
    Wu, W. B.
    Jin, S. M.