Macular Ganglion Cell Imaging Study: Interocular Symmetry of Ganglion Cell Inner Plexiform Layer Thickness in Normal Healthy Eyes

被引:45
|
作者
Lee, Sang-Yoon [1 ,2 ]
Jeoung, Jin Wook [1 ,2 ]
Park, Ki Ho [1 ,2 ]
Kim, Dong Myung [1 ,2 ]
机构
[1] Seoul Natl Univ Hosp, Dept Ophthalmol, Seoul 110744, South Korea
[2] Seoul Natl Univ, Dept Ophthalmol, Coll Med, Seoul, South Korea
关键词
NERVE-FIBER LAYER; OPTICAL COHERENCE TOMOGRAPHY; GLAUCOMA DIAGNOSTIC-ACCURACY; NORMAL-TENSION GLAUCOMA; DETECT GLAUCOMA; HIGH MYOPIA; FIELD LOSS; COMPLEX; ABILITY; RETINA;
D O I
10.1016/j.ajo.2014.10.032
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine cutoffs for interocular differences in ganglion cell-inner plexiform layer thickness in normal healthy eyes and to evaluate the diagnostic performance of these values for differentiating between normal subjects and glaucoma patients. DESIGN: Observational, cross-sectional study. METHODS: Macular and optic disc scanning were performed in 275 normal subjects, 58 glaucoma patients, and 58 normal controls by high-definition optical coherence tomography. The ganglion cell-inner plexiform layer thickness was calculated, and the normal ranges of the interocular differences were determined as 2.5th and 97.5th percentiles. The signed and absolute interocular differences were compared between normal subjects and glaucoma patients. RESULTS: The mean +/- standard deviation interocular difference in the average ganglion cell-inner plexiform layer thickness thickness was 0.10 +/- 2.31 pm, which was not statistically significant (P = .466). The 2.5th and 97.5th percentiles of the interocular difference were -4.10 mu m and + 5.00 mu m, respectively. On multiple regression analysis, the interocular difference in axial length was correlated with the interocular difference in average ganglion cell-inner plexiform layer thickness thickness (beta = 2.044, P = .003). The signed and absolute interocular differences in ganglion cell-inner plexiform layer thickness were higher in glaucoma patients than in normal subjects (all P <.001). Sensitivity and specificity of absolute interocular differences ranged from 25.9% to 51.7% and from 93.1% to 100.0%, respectively. CONCLUSIONS: Ganglion cell-inner plexiform layer thickness shows significant interocular symmetry in normal subjects. An absolute interocular difference exceeding normal limits may be indicative of glaucoma. (C) 2015 by Elsevier Inc. All rights reserved.
引用
收藏
页码:315 / 323
页数:9
相关论文
共 50 条
  • [21] Profile of macular ganglion cell-inner plexiform layer thickness in healthy 6.5 year- old Swedish children
    Arnljots, Urszula
    Nilsson, Maria
    Myrberg, Ida Hed
    Aden, Ulrika
    Hellgren, Kerstin
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [22] Macular ganglion cell-inner plexiform layer thickness for detection of early retinal toxicity of hydroxychloroquine
    Kan, Emrah
    Yakar, Konuralp
    Demirag, Mehmet Derya
    Gok, Mustafa
    INTERNATIONAL OPHTHALMOLOGY, 2018, 38 (04) : 1635 - 1640
  • [23] Diagnostic Ability of Macular Ganglion Cell-Inner Plexiform Layer Thickness in Chinese Glaucoma Suspects
    Liu, Xing
    Guo, Xinxing
    Xu, Xiaoyu
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [24] Profile of macular ganglion cell-inner plexiform layer thickness in healthy 6.5 year- old Swedish children
    Urszula Arnljots
    Maria Nilsson
    Ida Hed Myrberg
    Ulrika Åden
    Kerstin Hellgren
    BMC Ophthalmology, 20
  • [25] Ganglion Cell-Inner Plexiform Layer, Peripapillary Retinal Nerve Fiber Layer, and Macular Thickness in Eyes with Myopic β-Zone Parapapillary Atrophy
    Kwon, Jin-woo
    Choi, Jin A.
    Kim, Jung-sub
    La, Tae Yoon
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [26] Causes of ganglion cell-inner plexiform layer thinning in myopic eyes
    Shpak, Alexander A.
    Korobkova, Maria V.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (01) : 3 - 7
  • [27] Causes of ganglion cell-inner plexiform layer thinning in myopic eyes
    Alexander A. Shpak
    Maria V. Korobkova
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2020, 258 : 3 - 7
  • [28] The Effect of LASIK Procedure on Peripapillary Retinal Nerve Fiber Layer and Macular Ganglion Cell-Inner Plexiform Layer Thickness in Myopic Eyes
    Zivkovic, Maja
    Jaksic, Vesna
    Giarmoukakis, Athanassios
    Grentzelos, Michael
    Zlatanovic, Marko
    Zlatanovic, Gordana
    Miljkovic, Aleksandra
    Jovanovic, Svetlana
    Stamenkovic, Miroslav
    Kymionis, George
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [29] GANGLION CELL-INNER PLEXIFORM LAYER THICKNESS IN EYES WITH NONEXUDATIVE AGE-RELATED MACULAR DEGENERATION OF DIFFERENT DRUSEN SUBTYPES
    Nam, Ki Tae
    Chung, Hyun Woo
    Jang, Sungmin
    Hwang, Soon-Young
    Kim, Seong-Woo
    Oh, Jaeryung
    Yun, Cheolmin
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2021, 41 (08): : 1686 - 1696
  • [30] Variance Reduction in a Dataset of Normal Macular Ganglion Cell Plus Inner Plexiform Layer Thickness Maps with Application to Glaucoma Diagnosis
    Knighton, Robert W.
    Gregori, Giovanni
    Budenz, Donald L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (07) : 3653 - 3661