Estimation of HVL in computed tomography using CTDI measurements

被引:0
|
作者
Yang, Z. [1 ]
Chu, R. [1 ]
Ruan, C. [1 ]
机构
[1] Univ Oklahoma, Hlth Sci Ctr, Oklahoma City, OK USA
关键词
D O I
10.1118/1.2760387
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine the HVL of CT systems from CTDI dosimetry measurements without additional test, and to overcome the technical difficulties in CT HVL measurements. Method and Materials: The HVL of one multi‐detector CT scanner was measured when the scanner is static, over the available energy range (80∼140 kVp) and with different bow‐tie filter configurations. Commercial CT dose phantoms in compliance with FDA specifications were used to measure the exposures. Nine doses at the central, peripheral, and intermediate positions were measured for both head and body phantoms. Averages were taken for doses measured at axially symmetric positions of each phantom. These averages were compared to the central position dose measurements. The ratios were analyzed along with the HVL values measured under exactly the same conditions and fitted to second power polynomials. Combining the fitting parameters and dosimetry measurements from different machines, the corresponding HVL were predicted and compared to the measured value of each machine. Results: The HVL of the CT scanner were determined to be between 5 to 10 mm Al over the energy range assessed. When the values were plotted against the dose at the peripheral or intermediate position, normalized by center dose, the curves all fit to second power polynomials with R2>0.99. When applying the correlation obtained from the fittings to dosimetry measurements from different machines, the calculated HVLs are within 5% or 0.5 mm Al error of the measured values. Conclusion: This study showed that the data collected for the CTDI measurements can be directly used to estimate the HVL of CT scanners to certain accuracy. This will reduce the time and effort needed for medical physicists to determine the HVL of CT systems during acceptance testing and annual quality assurance surveys. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2340 / 2340
页数:1
相关论文
共 50 条
  • [21] Correction: Stature estimation using scapula measurements by postmortem computed tomography in the southern Thai population
    Tawachai Monum
    Thutchai Opaburanakul
    Wirachai Samai
    Komet Kosawiwat
    Chanathip Kawin
    Egyptian Journal of Forensic Sciences, 14 (1)
  • [22] ESTIMATION OF COMPUTED TOMOGRAPHY DOSE INDEX IN CONE BEAM COMPUTED TOMOGRAPHY: MOSFET MEASUREMENTS AND MONTE CARLO SIMULATIONS
    Kim, Sangroh
    Yoshizumi, Terry
    Toncheva, Greta
    Yoo, Sua
    Yin, Fang-Fang
    Frush, Donald
    HEALTH PHYSICS, 2010, 98 (05): : 683 - 691
  • [23] Polymer gel dosimetry on a multislice computed tomography scanner: Effect of changing parameters on CTDI
    Hill, B.
    Venning, A. J.
    Baldock, C.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2008, 24 (03): : 149 - 158
  • [24] Using a Cerenkov detector in HVL measurements for industrial electron linacs
    Li, Shuwei
    Mang, Kejun
    Wang, Yi
    Li, Jin
    Song, Jian-Jun
    Li, Yuanjing
    RADIATION MEASUREMENTS, 2011, 46 (08) : 726 - 729
  • [25] Computed tomography and pulmonary measurements
    Drummond, GB
    BRITISH JOURNAL OF ANAESTHESIA, 1998, 80 (05) : 665 - 671
  • [26] Estimation of stature and sex from skull measurements by multidetector computed tomography in Chinese
    Zhan, Meng-jun
    Cui, Jing-hui
    Zhang, Kui
    Chen, Yi-jiu
    Deng, Zhen-hua
    LEGAL MEDICINE, 2019, 41
  • [27] In vitro measurements of flow using multislice computed tomography (MSCT)
    Klaus Lackner
    Henning Bovenschulte
    Hartmut Stützer
    Thomas Just
    Hassan Al-Hassani
    Barbara Krug
    The International Journal of Cardiovascular Imaging, 2011, 27 : 795 - 804
  • [28] Canine Elbow Humeroulnar Incongruity Measurements Using Computed Tomography
    Snasil, R.
    Proks, P.
    Necasova, A.
    Michalcakova, K.
    Necas, A.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2017, 84 (04) : 299 - 303
  • [29] In vitro measurements of flow using multislice computed tomography (MSCT)
    Lackner, Klaus
    Bovenschulte, Henning
    Stuetzer, Hartmut
    Just, Thomas
    Al-Hassani, Hassan
    Krug, Barbara
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (06): : 795 - 804
  • [30] THE REPRODUCIBILITY OF BRONCHIAL CIRCUMFERENCE MEASUREMENTS USING COMPUTED-TOMOGRAPHY
    DESAI, SR
    WELLS, AU
    CHEAH, FK
    COLE, PJ
    HANSELL, DM
    BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (795): : 257 - 262