Optical Coherence Tomography and Histopathology Assessment After Implantation of First- and Second-Generation Drug-Eluting Stents in a Porcine Coronary Model

被引:13
|
作者
Hiranuma, Noritoshi [1 ]
Shinke, Toshiro [1 ]
Nakazawa, Gaku [2 ]
Otake, Hiromasa [1 ]
Matsumoto, Daisuke [1 ]
Ijichi, Takeshi [2 ]
Kawamori, Hiroyuki [1 ]
Nagoshi, Ryoji [1 ]
Osue, Tsuyoshi [1 ]
Shite, Junya [1 ]
Hirata, Ken-ichi [1 ]
机构
[1] Kobe Univ, Grad Sch Med, Div Cardiovasc & Resp Med, Dept Internal Med, Kobe, Hyogo 6500017, Japan
[2] Tokai Univ, Sch Med, Dept Cardiol, Isehara, Kanagawa 25911, Japan
关键词
Coronary artery disease; Drug-eluting stent; Histology; Optical coherence tomography; Vascular response; BARE-METAL STENTS; INTRAVASCULAR ULTRASOUND; NEOINTIMAL COVERAGE; ARTERY-DISEASE; FOLLOW-UP; RESTENOSIS; PACLITAXEL; THROMBOSIS; INSIGHTS; LESIONS;
D O I
10.1253/circj.CJ-14-0315
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: This study directly compared optical coherence tomography (OCT) and histopathology for the assessment of vascular response to first-and second-generation drug-eluting stents. Methods and Results: Sirolimus-, everolimus-, and biolimus-eluting stents (SES, EES, and BES, respectively) were randomly implanted into the coronary arteries of 12 porcine. OCT was conducted after implantation: at 1, 3, and 6 months; histopathology was assessed at 3 and 6 months. At 1-month OCT, EES had the highest neointimal area (NA) and lowest neointimal unevenness score (NUS). At 6 months, NA and NUS were equivalent among the stent types. Delta NA from 1 to 6 months was lowest for EES, and Delta NA correlated with the histopathological inflammation score at 6 months, which was highest for SES (P<0.001). The mean signal intensity (MSI) and the attenuation were different for the stent types at 3 months, and were associated with inflammation score. Moderate diagnostic efficiency for measuring MSI was found, with an optimal cut-off of 6.88 predicting a high (>= grade 3) inflammation score. Conclusions: EES had the greatest uniformity and the least neointimal proliferation and were associated with less persistent inflammation. OCT provides accurate morphometric data; furthermore, quantitative measurement of the optical properties may help assess histological inflammation, which was more predominantly associated with SES than with EES and BES.
引用
收藏
页码:2665 / 2673
页数:9
相关论文
共 50 条
  • [31] Clinical Presentation and Outcomes of In-stent Restenosis in Second-Generation Drug-Eluting Stents Compared to First Generation Drug-Eluting Stents
    Buchanan, Kyle
    Rogers, Toby
    Xu, Linzhi
    Iantorno, Micaela
    Gajanana, Deepak
    Ben-Dor, Itsik
    Suddath, William
    Satler, Lowell
    Waksman, Ron
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (04) : S18 - S18
  • [32] Difference of Tissue Characteristics between Early and Late Restenosis after Implanting Second-Generation Drug-Eluting Stents Assessed by Optical Coherence Tomography
    Jinnouchi, Hiroyuki
    Kuramitsu, Shoichi
    Domei, Takenori
    Ando, Kenji
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B240 - B241
  • [33] Characteristics of early versus late in-stent restenosis in second-generation drug-eluting stents: an optical coherence tomography study
    Song, Lei
    Mintz, Gary S.
    Yin, Dong
    Yamamoto, Myong Hwa
    Chin, Chee Yang
    Matsumura, Mitsuaki
    Kirtane, Ajay J.
    Parikh, Manish A.
    Moses, Jeffrey W.
    Ali, Ziad A.
    Shlofmitz, Richard A.
    Maehara, Akiko
    EUROINTERVENTION, 2017, 13 (03) : 294 - 302
  • [34] In vitro evaluation of second-generation drug-eluting coronary stents with 256-slice computed tomography
    Kuga, Y.
    Yoshimura, K.
    Ueda, H.
    Kido, A.
    Matsuhisa, S.
    Asawa, K.
    Yoshida, N.
    Yamasaki, M.
    Ueda, K.
    Nishida, Y.
    EUROPEAN HEART JOURNAL, 2013, 34 : 973 - 974
  • [35] Five-year outcomes after first- and second-generation drug-eluting stent implantation in all patients undergoing percutaneous coronary intervention
    Yano, Hideki
    Horinaka, Shigeo
    Watahiki, Manami
    Watanabe, Tomoko
    Ishimitsu, Toshihiko
    JOURNAL OF CARDIOLOGY, 2019, 74 (02) : 169 - 174
  • [36] Hypersensitivity Reaction in the US Food and Drug Administration-Approved Second-Generation Drug-Eluting Stents Histopathological Assessment With Ex Vivo Optical Coherence Tomography
    Otsuka, Fumiyuki
    Yahagi, Kazuyuki
    Ladich, Elena
    Kutys, Robert
    Alexander, Russell
    Fowler, David
    Virmani, Renu
    Joner, Michael
    CIRCULATION, 2015, 131 (03) : 322 - 324
  • [37] SECOND-GENERATION VERSUS FIRST-GENERATION DRUG-ELUTING STENTS IN PATIENTS ON HEMODIALYSIS
    Nishida, Koji
    Nakatsuma, Kenji
    Kawai, Kazuya
    Morimoto, Takeshi
    Kimura, Takeshi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1125 - 1125
  • [38] Comparison of First and Second-generation Drug-eluting Stents in Patients Presenting With Anemia
    Wanha, Wojciech
    Pluta, Aleksandra
    Marcinkiewicz, Kamil
    Kawecki, Damian
    Ochala, Andrzej
    Tendera, Michal
    Wojakowski, Wojciech
    CIRCULATION, 2013, 128 (22)
  • [39] LONG-TERM PROGNOSIS OF PATIENTS WITH IRREGULAR PROTRUSION AFTER SECOND-GENERATION DRUG-ELUTING STENT IMPLANTATION: OPTICAL COHERENCE TOMOGRAPHY STUDY
    Sanuki, Yoshinori
    Sonoda, Shinjo
    Miura, Toshiya
    Shimizu, Akiyoshi
    Takami, Hironori
    Anai, Reo
    Muraoka, Yoshitaka
    Tsuda, Yuki
    Araki, Masaru
    Otsuji, Yutaka
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1080 - 1080
  • [40] Safety and efficacy of first-generation and second-generation drug-eluting stents in the setting of acute coronary syndromes
    Gorla, Riccardo
    Loffi, Marco
    Verna, Edoardo
    Margonato, Alberto
    Salerno-Uriarte, Jorge
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2014, 15 (07) : 532 - 542