Optimum location and distribution of insulation layers on building walls with various orientations

被引:134
|
作者
Ozel, M. [1 ]
Pihtili, K. [1 ]
机构
[1] Firat Univ, Dept Mech Engn, TR-23279 Elazig, Turkey
关键词
location and distribution of insulation; orientations of wall; time lag; decrement factor;
D O I
10.1016/j.buildenv.2006.07.025
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, to determine optimum location and distribution of insulation in a wall, an analysis was made of 12 different wall configurations with different configurations of insulation layers. The investigation was carried out by using an implicit finite difference method for multilayer walls during typical summer and winter days in Elazig, Turkey. For this purpose, the location of insulation layers was varied across the wall thickness for each configuration while the masonry thickness and the total insulation thickness were held constant. The optimum location of insulation for the configurations analysed was obtained from consideration of time lag and decrement factor for various wall orientations in both summer and winter conditions. Results showed that the best thermal performance was obtained in the case that one of three equal pieces insulation layers was placed in the outdoor surface of wall, the second piece of insulation was placed in the middle of wall and third piece of insulation was placed in the indoor surface of wall. Furthermore, it was found that equal thicknesses of insulation layers placed in the indoor and outdoor surface of wall was better than different thicknesses from the point of view of maximum time lag and minimum decrement factor. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3051 / 3059
页数:9
相关论文
共 50 条
  • [41] Sound insulation prediction of double walls on elastic layers
    Van den Wyngaert, J.
    Schevenels, M.
    Reynders, E.
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON NOISE AND VIBRATION ENGINEERING (ISMA2020) / INTERNATIONAL CONFERENCE ON UNCERTAINTY IN STRUCTURAL DYNAMICS (USD2020), 2020, : 3451 - 3462
  • [42] Determination of optimum insulation thickness in different wall orientations and locations in Iran
    Ramin, Hadi
    Hanafizadeh, Pedram
    Akhavan-Behabadi, Mohammad Ali
    ADVANCES IN BUILDING ENERGY RESEARCH, 2016, 10 (02) : 149 - 171
  • [43] Influence of conjugate convective heat transfer on temperature fields in thin walls that organize liquid layers of various orientations
    Mitin, K. A.
    Kislitsyn, S. A.
    Berdnikov, V. S.
    XXXV SIBERIAN THERMOPHYSICAL SEMINAR, 2019, 2019, 1382
  • [44] Determination of Optimum Insulation Thickness on Different Wall Orientations in a Hot Climate
    Arslan, Erhan
    Karagoz, Irfan
    PROCEEDINGS OF 3RD INTERNATIONAL SUSTAINABLE BUILDINGS SYMPOSIUM (ISBS 2017), VOL 2, 2018, 7 : 145 - 157
  • [45] Influence of glazing area on optimum thickness of insulation for different wall orientations
    Ozel, Meral
    APPLIED THERMAL ENGINEERING, 2019, 147 : 770 - 780
  • [46] Seismic Response of Y-Shape Multi-Storey Building with Optimum Location of Shear Walls
    Banerjee, Rajiv
    Srivastava, Jyoti Bhushan
    Gupta, Nakul
    INDIAN JOURNAL OF ENGINEERING AND MATERIALS SCIENCES, 2022, 29 (05) : 615 - 621
  • [47] The environmental impact of optimum insulation thickness for external walls of buildings
    Dombayci, Oe. Altan
    BUILDING AND ENVIRONMENT, 2007, 42 (11) : 3855 - 3859
  • [48] Parametric Investigation of Optimum Thermal Insulation Thickness for External Walls
    Kaynakli, Omer
    ENERGIES, 2011, 4 (06): : 913 - 927
  • [49] Heat transfer characteristics and optimum insulation thickness for cavity walls
    Al-Sanea, Sami A.
    Zedan, M.F.
    Al-Ajlan, Saleh A.
    Abdul Hadi, Atif S.
    Journal of Thermal Envelope and Building Science, 2003, 26 (03): : 285 - 307
  • [50] Measurements behind Internal Insulation on Solid Masonry Walls with Different Orientations and Degrees of Repair in a Danish Multi-story Building
    Vanhoutteghem, Lies
    Hoegh, Britt Haker
    Hansen, Thor
    12TH NORDIC SYMPOSIUM ON BUILDING PHYSICS (NSB 2020), 2020, 172