In Vivo Measurement of Vocal Fold Surface Resistance

被引:3
|
作者
Mizuta, Masanobu [1 ,2 ]
Kurita, Takashi [2 ]
Dillon, Neal P. [6 ]
Kimball, Emily E. [3 ]
Garrett, C. Gaelyn [2 ]
Sivasankar, M. Preeti [8 ]
Webster, Robert J., III [2 ,4 ,5 ,6 ,7 ]
Rousseau, Bernard [2 ,3 ,6 ,8 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Otolaryngol Head & Neck Surg, Kyoto, Japan
[2] Vanderbilt Univ, Med Ctr, Dept Otolaryngol, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Med Ctr, Dept Hearing & Speech Sci, Nashville, TN USA
[4] Vanderbilt Univ, Med Ctr, Dept Neurol Surg, Nashville, TN USA
[5] Vanderbilt Univ, Med Ctr, Dept Urol Surg, Nashville, TN USA
[6] Vanderbilt Univ, Dept Mech Engn, Nashville, TN 37235 USA
[7] Vanderbilt Univ, Dept Elect Engn, Nashville, TN 37235 USA
[8] Purdue Univ, Dept Speech Language & Hearing Sci, W Lafayette, IN 47907 USA
来源
LARYNGOSCOPE | 2017年 / 127卷 / 10期
基金
美国国家卫生研究院;
关键词
Epithelium; vocal fold surface resistance; phonotrauma; vocal fold; voice; EVOKED RABBIT PHONATION; EPITHELIAL BARRIER; TIGHT JUNCTIONS; REFLUX; MODEL; VIBRATION; DIAGNOSIS; GENES; MUCUS;
D O I
10.1002/lary.26715
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives/Hypothesis: A custom-designed probe was developed to measure vocal fold surface resistance in vivo. The purpose of this study was to demonstrate proof of concept of using vocal fold surface resistance as a proxy of functional tissue integrity after acute phonotrauma using an animal model. Study Design: Prospective animal study. Methods: New Zealand White breeder rabbits received 120 minutes of airflow without vocal fold approximation (control) or 120 minutes of raised intensity phonation (experimental). The probe was inserted via laryngoscope and placed on the left vocal fold under endoscopic visualization. Vocal fold surface resistance of the middle one-third of the vocal fold was measured after 0 (baseline), 60, and 120 minutes of phonation. After the phonation procedure, the larynx was harvested and prepared for transmission electron microscopy. Results: In the control group, vocal fold surface resistance values remained stable across time points. In the experimental group, surface resistance (X% +/- Y% relative to baseline) was significantly decreased after 120 minutes of raised intensity phonation. This was associated with structural changes using transmission electron microscopy, which revealed damage to the vocal fold epithelium after phonotrauma, including disruption of the epithelium and basement membrane, dilated paracellular spaces, and alterations to epithelial microprojections. In contrast, control vocal fold specimens showed well-preserved stratified squamous epithelia. Conclusions: These data demonstrate the feasibility of measuring vocal fold surface resistance in vivo as a means of evaluating functional vocal fold epithelial barrier integrity. Device prototypes are in development for additional testing, validation, and for clinical applications in laryngology.
引用
收藏
页码:E364 / E370
页数:7
相关论文
共 50 条
  • [21] Numerical study of the effects of inferior and superior vocal fold surface angles on vocal fold pressure distributions
    Li, Sheng
    Scherer, Ronald C.
    Wan, MingXi
    Wang, SuPin
    Wu, HuiHui
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2006, 119 (05): : 3003 - 3010
  • [22] Measurement of human vocal fold vibrations with laser triangulation
    Manneberg, G
    Hertegård, S
    Liljencrantz, J
    OPTICAL ENGINEERING, 2001, 40 (09) : 2041 - 2044
  • [23] VOCAL FOLD VIBRATIONS IN DYSPHONIA - MODEL VS MEASUREMENT
    CHILDERS, DG
    ALSAKA, YA
    HICKS, DM
    MOORE, GP
    JOURNAL OF PHONETICS, 1986, 14 (3-4) : 429 - 434
  • [24] Measurement of mucosal wave velocity on the superior surface of vocal fold using the Laser Doppler Vibrometer
    Wu, Liang
    Chigan, Pengju
    Wang, Supin
    Wan, Mingxi
    Shengxue Xuebao/Acta Acustica, 2020, 45 (01): : 124 - 130
  • [25] A CLINICAL PROCEDURE FOR LINEAR MEASUREMENT AT THE VOCAL FOLD LEVEL
    FEX, S
    FEX, B
    HIRANO, M
    JOURNAL OF VOICE, 1991, 5 (04) : 328 - 331
  • [26] MEASUREMENT OF VOCAL FOLD INTRAGLOTTAL PRESSURE AND IMPACT STRESS
    JIANG, JJQ
    TITZE, IR
    JOURNAL OF VOICE, 1994, 8 (02) : 132 - 144
  • [27] Vocal fold paresis accompanying vocal fold polyps
    Sevtap Akbulut
    Rahsan Adviye Inan
    Hande Altintas
    Ibrahim Gul
    Derya Berk
    Mustafa Paksoy
    European Archives of Oto-Rhino-Laryngology, 2015, 272 : 149 - 157
  • [28] Vocal fold paresis accompanying vocal fold polyps
    Akbulut, Sevtap
    Inan, Rahsan Adviye
    Altintas, Hande
    Gul, Ibrahim
    Berk, Derya
    Paksoy, Mustafa
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2015, 272 (01) : 149 - 157
  • [29] The anisotropic nature of the human vocal fold: an ex vivo study
    Rohlfs, Anna-Katharina
    Goodyer, Eric
    Clauditz, Till
    Hess, Markus
    Kob, Malte
    Koops, Susan
    Pueschel, Klaus
    Roemer, Frank W.
    Mueller, Frank
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2013, 270 (06) : 1885 - 1895
  • [30] The anisotropic nature of the human vocal fold: an ex vivo study
    Anna-Katharina Rohlfs
    Eric Goodyer
    Till Clauditz
    Markus Hess
    Malte Kob
    Susan Koops
    Klaus Püschel
    Frank W. Roemer
    Frank Müller
    European Archives of Oto-Rhino-Laryngology, 2013, 270 : 1885 - 1895