In Vivo Measurement of Vocal Fold Surface Resistance

被引:3
|
作者
Mizuta, Masanobu [1 ,2 ]
Kurita, Takashi [2 ]
Dillon, Neal P. [6 ]
Kimball, Emily E. [3 ]
Garrett, C. Gaelyn [2 ]
Sivasankar, M. Preeti [8 ]
Webster, Robert J., III [2 ,4 ,5 ,6 ,7 ]
Rousseau, Bernard [2 ,3 ,6 ,8 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Otolaryngol Head & Neck Surg, Kyoto, Japan
[2] Vanderbilt Univ, Med Ctr, Dept Otolaryngol, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Med Ctr, Dept Hearing & Speech Sci, Nashville, TN USA
[4] Vanderbilt Univ, Med Ctr, Dept Neurol Surg, Nashville, TN USA
[5] Vanderbilt Univ, Med Ctr, Dept Urol Surg, Nashville, TN USA
[6] Vanderbilt Univ, Dept Mech Engn, Nashville, TN 37235 USA
[7] Vanderbilt Univ, Dept Elect Engn, Nashville, TN 37235 USA
[8] Purdue Univ, Dept Speech Language & Hearing Sci, W Lafayette, IN 47907 USA
来源
LARYNGOSCOPE | 2017年 / 127卷 / 10期
基金
美国国家卫生研究院;
关键词
Epithelium; vocal fold surface resistance; phonotrauma; vocal fold; voice; EVOKED RABBIT PHONATION; EPITHELIAL BARRIER; TIGHT JUNCTIONS; REFLUX; MODEL; VIBRATION; DIAGNOSIS; GENES; MUCUS;
D O I
10.1002/lary.26715
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives/Hypothesis: A custom-designed probe was developed to measure vocal fold surface resistance in vivo. The purpose of this study was to demonstrate proof of concept of using vocal fold surface resistance as a proxy of functional tissue integrity after acute phonotrauma using an animal model. Study Design: Prospective animal study. Methods: New Zealand White breeder rabbits received 120 minutes of airflow without vocal fold approximation (control) or 120 minutes of raised intensity phonation (experimental). The probe was inserted via laryngoscope and placed on the left vocal fold under endoscopic visualization. Vocal fold surface resistance of the middle one-third of the vocal fold was measured after 0 (baseline), 60, and 120 minutes of phonation. After the phonation procedure, the larynx was harvested and prepared for transmission electron microscopy. Results: In the control group, vocal fold surface resistance values remained stable across time points. In the experimental group, surface resistance (X% +/- Y% relative to baseline) was significantly decreased after 120 minutes of raised intensity phonation. This was associated with structural changes using transmission electron microscopy, which revealed damage to the vocal fold epithelium after phonotrauma, including disruption of the epithelium and basement membrane, dilated paracellular spaces, and alterations to epithelial microprojections. In contrast, control vocal fold specimens showed well-preserved stratified squamous epithelia. Conclusions: These data demonstrate the feasibility of measuring vocal fold surface resistance in vivo as a means of evaluating functional vocal fold epithelial barrier integrity. Device prototypes are in development for additional testing, validation, and for clinical applications in laryngology.
引用
收藏
页码:E364 / E370
页数:7
相关论文
共 50 条
  • [1] In vivo measurement of the elastic properties of the human vocal fold
    Goodyer, E
    Muller, F
    Bramer, B
    Chauhan, D
    Hess, M
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2006, 263 (05) : 455 - 462
  • [2] In vivo measurement of the elastic properties of the human vocal fold
    Eric Goodyer
    Frank Muller
    Brian Bramer
    Dilip Chauhan
    Markus Hess
    European Archives of Oto-Rhino-Laryngology and Head & Neck, 2006, 263 : 455 - 462
  • [3] Quantitative Evaluation of the In Vivo Vocal Fold Medial Surface Shape
    Vahabzadeh-Hagh, Andrew M.
    Zhang, Zhaoyan
    Chhetri, Dinesh K.
    JOURNAL OF VOICE, 2017, 31 (04) : 513.e15 - 513.e23
  • [4] Medial surface dynamics of an in vivo canine vocal fold during phonation
    Döllinger, M
    Berry, DA
    Berke, GS
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2005, 117 (05): : 3174 - 3183
  • [5] In Vivo Automatic and Quantitative Measurement of Adult Human Larynx and Vocal Fold Images
    Kuo, Chung-Feng Jeffrey
    Lin, Chun-Shu
    Chiang, Kai-Yao
    Barman, Jagadish
    Liu, Shao-Cheng
    JOURNAL OF VOICE, 2023, 37 (05) : 764 - 771
  • [6] Measurement of adult vocal fold length
    Su, MC
    Yeh, TH
    Tan, CT
    Lin, CD
    Linne, OC
    Lee, SY
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2002, 116 (06): : 447 - 449
  • [7] In Vivo Measurement of Pediatric Vocal Fold Motion Using Structured Light Laser Projection
    Patel, Rita R.
    Donohue, Kevin D.
    Lau, Daniel
    Unnikrishnan, Harikrishnan
    JOURNAL OF VOICE, 2013, 27 (04) : 463 - 472
  • [8] Non-invasive in vivo measurement of the shear modulus of human vocal fold tissue
    Kazemirad, Siavash
    Bakhshaee, Hani
    Mongeau, Luc
    Kost, Karen
    JOURNAL OF BIOMECHANICS, 2014, 47 (05) : 1173 - 1179
  • [9] Vocal fold atrophy: Quantitative glottic measurement and vocal function
    Omori, K
    Slavit, DH
    Matos, C
    Kojima, H
    Kacker, A
    Blaugrund, SM
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1997, 106 (07): : 544 - 551
  • [10] In Vivo Vocal Fold Cover Layer Replacement
    Long, Jennifer
    Salinas, Jonathan
    Rafizadeh, Sassan
    Luegmair, Georg
    Zhang, Zhaoyan
    Chhetri, Dinesh
    LARYNGOSCOPE, 2015, 125 (02): : 406 - 411