Transcatheter closure of "Surgical" ostium secundum atrial septal defects with GORE® Cardioform ASD Occluder

被引:3
|
作者
Santoro, Giuseppe [1 ]
Pizzuto, Alessandra [1 ]
Cuman, Magdalena [1 ]
Haxhiademi, Dorela [2 ]
Marchese, Pietro [1 ]
Franchi, Eliana [1 ]
Marrone, Chiara [1 ]
Pak, Vitali [3 ]
Assanta, Nadia [1 ]
Cantinotti, Massimiliano [1 ]
机构
[1] Tuscany Fdn G Monasterio, Natl Res Council, Pediat Cardiol & Cardiac Surg, Heart Hosp G Pasquinucci, Massa, Italy
[2] Tuscany Fdn G Monasterio, Anesthesia & Intens Care Unit, Heart Hosp G Pasquinucci, Natl Res Council, Massa, Italy
[3] Tuscany Fdn G Monasterio, Natl Res Council, Pediat Cardiac Surg, Heart Hosp G Pasquinucci, Massa, Italy
关键词
atrial septal defect; device; interventional cardiac catheterization; low-weight child; DEVICE CLOSURE; PERCUTANEOUS CLOSURE; OVAL FOSSA; FEASIBILITY; CHILDREN; IMPACT;
D O I
10.1111/jocs.16786
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To evaluate the GORE (R) Cardioform ASD Occluder (GCA)(WL Gore & Associates) device for closure of ostium secundum atrial septal defects (ASDs) with predicted indication for surgical correction. Background Closure of large ASD in small children by transcatheter approach is still challenging. This study evaluated the results of GCA in this subset of patients in a tertiary referral center. Methods Between January 2020 and March 2022, 97 children underwent transcatheter ASD closure at our Institution. Of them, 38 had a large defect (diameter/weight > 1.2 or diameter/body surface area > 20 mm/m(2)), predicted suitable for surgery and underwent closure with GCA. Procedure results and midterm outcome are reported. Results Patients' age and weight were 5.5 +/- 1.5 years and 19.7 +/- 4.7 kg, respectively. Absolute and relative ASD size was 21.5 +/- 3.6 mm, 1.1 +/- 0.2 mm/kg, and 27.7 +/- 4.6 mm/m(2), respectively, resulting in QP/QS of 2.0 +/- 0.8. Three patients were sent to surgery after balloon sizing. Four of the remaining 35 patients who underwent device deployment, needed rescue or elective surgery due to device embolization (n = 1), device instability (n = 2) or new-onset tricuspid valve regurgitation (n = 1). Procedure feasibility was 88.6%. Major complications were recorded in two patients (5.7%). Minor complications were recorded in five patients (14.3%). Complete closure at discharge was 90.3% (28/31 pts) rising to 100% at the last follow-up evaluation. Wireframe fracture rate at the 6 months examination was 52%, without clinical and instrumental consequences. Conclusions Percutaneous treatment with GCA device is effective and safe in a high percentage of ASD children with predicted indications for surgical correction.
引用
收藏
页码:3200 / 3206
页数:7
相关论文
共 50 条
  • [41] Cardiac mechanical remodelling after ASD closure with gore cardioform ASD occluder in children
    Di Candia, Angela
    Castaldi, Biagio
    Fumanelli, Jennifer
    Sirico, Domenico
    Vida, Vladimiro
    Padalino, Massimo
    Santoro, Giuseppe
    Di Salvo, Giovanni
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2020, 22 (0N) : N47 - N48
  • [42] Transcatheter Closure of Residual Leak Using Gore Cardioform Occluder After Failed Surgical Ligation of Left Atrial Appendage
    Mandava, Sri
    Gade, Akhil
    Salagundla, Nethuja
    Thambidorai, Senthil
    CIRCULATION, 2022, 146
  • [43] Effectiveness of the Amplatzer™ device for transcatheter closure of an ostium secundum atrial septal defect
    Cardoso, Cristiano Oliveira
    Rossi Filho, Raul Ivo
    Machado, Paulo Renato
    Galant Francois, Lisia M.
    Horowitz, Estela S. K.
    Sarmento-Leite, Rogerio
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2007, 88 (04) : 384 - 389
  • [44] Novel Delivery Technique for Atrial Septal Defect Closure in Young Children Utilizing the GORE® CARDIOFORM® Septal Occluder
    Anderson, Jason H.
    Fraint, Hannah
    Moore, Phillip
    Cabalka, Allison K.
    Taggart, Nathaniel W.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 89 (07) : 1232 - 1238
  • [45] BUDGET IMPACT ANALYSIS OF SEPTAL OCCLUDER FOR PERCUTANEOUS CLOSURE OF ATRIAL SEPTAL DEFECT TYPE OSTIUM SECUNDUM
    Senna, K. M. S.
    Costa, M. G.
    Tura, B. R.
    Correia, M. G.
    Santos, M. S.
    VALUE IN HEALTH, 2013, 16 (07) : A704 - A704
  • [46] Transcatheter closure of atrial septal defects in adults with the Amplatzer septal occluder
    Dhillon, R
    Thanopoulos, B
    Tsaousis, G
    Triposkiadis, F
    Kyriakidis, M
    Redington, A
    HEART, 1999, 82 (05) : 559 - 562
  • [47] Transcatheter closure of atrial septal defects in adults with the amplatzer septal occluder
    Dhillon, R
    Thanopoulos, B
    Triposkladis, F
    Tsaousis, G
    Kyriakidis, M
    Redington, A
    CIRCULATION, 1998, 98 (17) : 619 - 619
  • [48] Transcatheter closure of secundum atrial septal defects in adults with the Amplatzer septal occluder: Intermediate and long-term results
    Christian Spies
    Ines Timmermanns
    Rainer Schräder
    Clinical Research in Cardiology, 2007, 96 : 340 - 346
  • [49] Transcatheter closure of secundum atrial septal defects in adults with the Amplatzer septal occluder:: Intermediate and long-term results
    Spies, C.
    Timmermanns, I.
    Schraeder, R.
    CLINICAL RESEARCH IN CARDIOLOGY, 2007, 96 (06) : 340 - 346
  • [50] Secundum Atrial Septal Defects Transcatheter Closure: An Updated Reappraisal
    Rigatelli, Gianluca
    Gianese, Filippo
    Zuin, Marco
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2022, 44 : 92 - 97