Examining Hemodialysis Reliable Outflow catheter performance and cost in hemodialysis access

被引:11
|
作者
Torrent, Daniel J. [1 ]
Maness, Mandy R. [1 ]
Kachare, Swapnil D. [1 ]
Zink, Jill N. [2 ]
Haisch, Carl E. [1 ]
Harland, Robert C. [1 ]
Morgan, Claire [1 ]
Guyton, Rodney L. [3 ]
Colomb, Avery G. [3 ]
Barham, David W. [3 ]
Katz, Eric C. [3 ]
Stoner, Michael C. [4 ]
机构
[1] E Carolina Univ, Dept Surg, Greenville, NC USA
[2] E Carolina Univ, Dept Cardiovasc Surg, Greenville, NC USA
[3] E Carolina Univ, Brody Sch Med, Greenville, NC USA
[4] Univ Rochester, Dept Surg, Rochester, NY USA
关键词
Vascular access; Hemodialysis access; Hemodialysis; Hemodialysis Realiable Outflow; HeRO; Arteriovenous graft; VASCULAR ACCESS; HERO DEVICE; EXPERIENCE; FISTULAS;
D O I
10.1016/j.jss.2014.03.016
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The Hemodialysis Reliable Outflow (HeRO) vascular access device is a hybrid polytetrafluoroethylene graft-stent construct designed to address central venous occlusive disease. Although initial experience has demonstrated excellent mid-term patency rates, subsequent studies have led to external validity questions. The purpose of this study was to examine a single center experience with this vascular access device in challenging access cases with associated costs. Methods: A retrospective study representing the authors' cumulative HeRO vascular access device experience was undertaken. The primary endpoint was graft failure or death, with secondary endpoints including secondary intervention rates and cost. Results: Forty-one patients with 15,579 HeRO days and a mean of 12.7 +/- 1.5 mo with the vascular access device were available for analysis. Secondary patency was 81.6% at 6 mo and 53.7% at 12 mo. The reintervention rate was 2.84 procedures per HeRO vascular access device year. Associated HeRO costs related to subsequent procedures were estimated at $34,713.63 per patient/y. Conclusions: These data on the patency and primary outcome data diverge significantly from initial multicenter studies and represent a real-world application of this technology. It is costly to maintain patency. Use of HeRO vascular access devices should be judicious with outcome expectations reduced. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [21] Restoring Access in a Thrombosed Hemodialysis Reliable Outflow Graft Using the InThrill Thrombectomy System
    Devireddy, Rakesh Reddy
    Qaqi, Osama
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (03)
  • [22] Successful Management of Recurrent Tunneled Dialysis Catheter Infections with the Hemodialysis Reliable Outflow Graft Device
    Papadoulas, Spyros
    Kitrou, Panagiotis
    Tsantrizos, Polyzois
    Papachristou, Evangelos
    Apostolopoulou, Paraskevi G.
    Konstantinos, Moulakakis G.
    Stavros, Kakkos K.
    SAUDI JOURNAL OF KIDNEY DISEASES AND TRANSPLANTATION, 2023, 34 (05) : 443 - 448
  • [23] A NEW VASCULAR ACCESS CATHETER FOR HEMODIALYSIS
    ULDALL, R
    DEBRUYNE, M
    BESLEY, M
    MCMILLAN, J
    SIMONS, M
    FRANCOEUR, R
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1993, 21 (03) : 270 - 277
  • [24] Outcomes and performance of the tesio twin catheter system placed for hemodialysis access
    Wivell, W
    Bettmann, MA
    Baxter, B
    Langdon, DR
    Remilliard, B
    Chobanian, M
    RADIOLOGY, 2001, 221 (03) : 697 - 703
  • [25] Outcome and performance of the Tesio twin catheter system placed for hemodialysis access
    Wivell, WA
    David, LR
    Brian, B
    Michael, B
    RADIOLOGY, 1998, 209P : 455 - 455
  • [26] THE TESIO CATHETER - A SUCCESSFUL ALTERNATIVE FOR HEMODIALYSIS ACCESS
    VERGARA, G
    ALIPARO, P
    LASKER, N
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1994, 5 (03): : 428 - 428
  • [27] DOUBLE LUMEN CATHETER AS VASCULAR ACCESS FOR HEMODIALYSIS
    ZUNIGA, C
    VUKUSIC, A
    VIAL, S
    VACCAREZZA, A
    PEREZ, R
    REVISTA MEDICA DE CHILE, 1989, 117 (09) : 991 - 996
  • [28] Axillary catheter for hemodialysis, an alternative vascular access
    Valencia, C. A. Restrepo
    NEFROLOGIA, 2008, 28 (01): : 77 - 81
  • [29] TENCKHOFF CATHETER AS A PRIMARY HEMODIALYSIS VASCULAR ACCESS
    LIGGETT, RA
    KEARNEY, MM
    DIALYSIS & TRANSPLANTATION, 1988, 17 (10) : 522 - &
  • [30] Modified proximalization of arterial inflow using a hemodialysis reliable outflow graft in a patient with vascular access failure
    Cifuentes, Sebastian
    Tabiei, Armin
    DeMartino, Randall R.
    JOURNAL OF VASCULAR SURGERY CASES INNOVATIONS AND TECHNIQUES, 2022, 8 (04): : 859 - 860