Systematic and Random Mapping Errors in Structure - Function Analysis of the Macula

被引:4
|
作者
Montesano, Giovanni [1 ,2 ,3 ]
Rossetti, Luca M. [2 ]
Allegrini, Davide [4 ]
Romano, Mario R. [4 ]
Garway-Heath, David F. [3 ]
Crabb, David P. [1 ]
机构
[1] City Univ London, Optometry & Visual Sci, London, England
[2] Univ Milan, ASST Santi Paolo & Carlo, Milan, Italy
[3] Moorfields Eye Hosp NHS Fdn Trust, NIHR Biomed Res Ctr, UCL Inst Ophthalmol, London, England
[4] Humanitas Univ, Humanitas Gavazzeni Hosp, Eye Unit, Bergamo, Italy
来源
关键词
glaucoma; optical coherence tomography; visual field; perimetry; fixation; GLAUCOMATOUS DAMAGE; FIXATION STABILITY; VISUAL-FIELDS; GAZE TRACKING; EYE-MOVEMENTS; MICROPERIMETRY; THRESHOLD; OCT; PERIMETRY; DEFECTS;
D O I
10.1167/tvst.10.2.21
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Quantify the spatial error in mapping perimetric stimuli for structure-function analysis resulting from the choice of mapping scheme and eye movements. Methods: We analyzed data from 17 healthy and 30 glaucomatous participants. Structural data of the macula were collected with a spectral-domain optical coherence tomography. We extracted eye movement data and projection locations from a fundus tracking perimeter and quantified the retinal location mapping error (distance between the actual and the intended stimulus location in degrees from the fovea) for non-tracked perimetry in a 10-2 grid. First, we evaluated whether rotating the 10-2 grid to match the fovea-disc axis improved mapping accuracy. Second, we analyzed the effect of eccentric fixation, random eye movements, and gaze attraction from seen stimuli on projection accuracy and spread of fixation, measured with the 95% bivariate contour ellipse area (95% BCEA). We used generalized linear mixed models for our statistical analyses. Results: Rotating the 10-2 grid to match the fovea-disc axis significantly increased the mapping error (P < 0.001). Eye movements evoked by seen stimuli significantly increased the projection error during the test (P < 0.001). Removing such eye movements significantly reduced the 95% BCEA (P < 0.001). Eccentric fixation also significantly contributed to the projection error (P < 0.001), and its effect was larger in glaucoma patients (P < 0.001). Conclusions: Rotating the perimetric grid to match the fovea-disc axis is not recommended. Fixation eccentricity and instability should be taken into account for structure-function analyses. Translational Relevance: Accounting for fixation can improve structure-function mapping in glaucoma.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 50 条
  • [21] Macula Structure Function Relationships Incorporating the Stimulus Area
    Patel, Nimesh Bhikhu
    Harwerth, Ronald S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [22] The Structure and Function of the Macula in Patients with Advanced Retinitis Pigmentosa
    Vamos, Rita
    Tatrai, Erika
    Nemeth, Janos
    Holder, Graham E.
    DeBuc, Delia Cabrera
    Somfai, Gabor Mark
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (11) : 8425 - 8432
  • [23] PROBABILITY OF INDECOMPOSABILITY OF A RANDOM MAPPING FUNCTION
    KATZ, L
    ANNALS OF MATHEMATICAL STATISTICS, 1955, 26 (03): : 512 - 517
  • [24] Systematic and random errors in compression testing of trabecular bone
    Keaveny, TM
    Pinilla, TP
    Crawford, RP
    Kopperdahl, DL
    Lou, A
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1997, 15 (01) : 101 - 110
  • [25] Compensation of random and systematic timing errors in sampling oscilloscopes
    Hale, Paul D.
    Wang, C. M.
    Williams, Dylan F.
    Remley, Kate A.
    Wepman, Joshua D.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2006, 55 (06) : 2146 - 2154
  • [26] Setting Alarm Thresholds in Measurements with Systematic and Random Errors
    Burr, Tom
    Bonner, Elisa
    Krzysztoszek, Kamil
    Norman, Claude
    STATS, 2019, 2 (02): : 259 - 271
  • [27] RANDOM AND SYSTEMATIC-ERRORS IN THERMOPHYSICAL PROPERTY MEASUREMENTS
    EUBANK, PT
    VANPEURSEM, D
    CHAO, YP
    GUPTA, D
    AICHE JOURNAL, 1994, 40 (09) : 1580 - 1593
  • [28] Reduction of random and systematic errors of test cell measurements
    Jezowska, Anna
    Schipolowski, Thomas
    Wozny, Guenter
    DESALINATION, 2006, 200 (1-3) : 160 - 162
  • [29] SYSTEMATIC AND RANDOM ERRORS IN ANALYTE ADDITION POTENTIOMETRY - A REVIEW
    MIDGLEY, D
    ANALYST, 1989, 114 (01) : 1 - 13
  • [30] PERFORMANCE MODELS OF CORRELATORS WITH RANDOM AND SYSTEMATIC PHASE ERRORS
    COHN, RW
    OPTICAL ENGINEERING, 1995, 34 (06) : 1673 - 1679