Analysis of Energy Efficiency for Coal-fired Power Units based on Data Envelopment Analysis Model

被引:11
|
作者
Song, Chenxi [1 ]
Li, Mingjia [1 ]
Zhang, Fan [1 ]
He, Yaling [1 ]
Tao, Wenquan [1 ]
机构
[1] Xi An Jiao Tong Univ, Minist Educ, Key Lab Thermofluid Sci & Engn, Xian Ning West Rd, Xian 710049, Shaanxi, Peoples R China
关键词
Coal-fired power unit; data envelopment analysis (DEA); energy efficiency (EE); PLANTS;
D O I
10.1016/j.egypro.2014.11.992
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this article, the non-parametric data envelopment analysis method (DEA) is employed to evaluate energy efficiency (EE) of coal-fired power units in China. The data set contains inputs and outputs of 34 coal-fired power units with the capacity of 600MW. Input-oriented CCR (Charnes-Cooper-Rhodes) is employed. The value of CCR efficiency calculated in this paper is based on two input parameters: fuel consumption and auxiliary power consumption. The relations between EE and factors including, parameter of main steam, cooling method, capacity utilization rate and annual utilization hours are analysed. Some relation curves are fitted. (C) 2014 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:904 / 909
页数:6
相关论文
共 50 条
  • [21] Spatial autocorrelation analysis of the environmental efficiency of coal-fired power plants in China
    Tomoaki Nakaishi
    Fumiya Nagashima
    Shigemi Kagawa
    Clean Technologies and Environmental Policy, 2022, 24 : 2177 - 2192
  • [22] Cost analysis for FGD units of coal-fired power plants: A case study in Turkey
    Acibadem University, Faculty of Engineering, Istanbul, Turkey
    不详
    不详
    Guney, I. (irfan.guney@acibadem.edu.tr), 1600, Sila Science, University Mah Mekan Sok, No 24, Trabzon, Turkey (28):
  • [23] Cost analysis for FGD units of coal-fired power plants: a case study in Turkey
    Guney, Irfan
    Kilic, Osman
    Acarkan, Bora
    Ay, Selim
    ENERGY EDUCATION SCIENCE AND TECHNOLOGY PART A-ENERGY SCIENCE AND RESEARCH, 2012, 28 (02): : 983 - 994
  • [24] Methods and research status of energy consumption analysis and optimization for coal-fired generator units
    Zhang, Yuanshu
    Zhao, Yuzhu
    Chen, Hao
    Wu, Xi
    Meng, Fanyang
    2019 5TH INTERNATIONAL CONFERENCE ON ENERGY MATERIALS AND ENVIRONMENT ENGINEERING, 2019, 295
  • [25] Economic Analysis of Peaking Regulation of Coal-fired Generating Units Under Big Data
    Yang Z.
    Li K.
    Wang N.
    Li R.
    Jin Z.
    Yang M.
    Guo X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (16): : 4808 - 4818
  • [26] The Research of Utilization Hours of Coal-Fired Power Generation Units Based on Electric Energy Balance
    Liu, Junhui
    Yang, Jianlian
    Wang, Jiangbo
    Yang, Meng
    Tian, Chunzheng
    He, Xinhui
    2017 3RD INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND MATERIAL APPLICATION (ESMA2017), VOLS 1-4, 2018, 108
  • [27] Using energy and exergy analysis to compare different coal-fired power plants
    Tontu, Mehmet
    Sahin, Besir
    Bilgili, Mehmet
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2024, 46 (01) : 4314 - 4329
  • [28] A decision analysis model for reducing carbon emission from coal-fired power plants and its compensatory units
    Kumari, Shalini
    Bera, Sasadhar
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2022, 301
  • [29] THE OPERATING PARAMETERS SENSITIVE ANALYSIS OF ENERGY CONSUMPTION FOR COAL-FIRED POWER PLANT
    Wang, Hui-Jie
    Zhang, Chun-Fa
    Zhao, Ning
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON WAVELET ANALYSIS AND PATTERN RECOGNITION, VOLS 1 AND 2, 2008, : 862 - 867
  • [30] Big-Data-Mining-Based Improved K-Means Algorithm for Energy Use Analysis of Coal-Fired Power Plant Units: A Case Study
    Liu, Binghan
    Fu, Zhongguang
    Wang, Pengkai
    Liu, Lu
    Gao, Manda
    Liu, Ji
    ENTROPY, 2018, 20 (09)