Effect of hemodialysis on intraocular lens power calculation

被引:5
|
作者
Caliskan, Sinan [1 ]
Celikay, Osman [1 ]
Bicer, Tolga [1 ]
Ayli, Mehmet Deniz [2 ]
Gurdal, Canan [1 ]
机构
[1] Diskapi Yildirim Beyazit Training & Res Hosp, Dept Ophthalmol, Ankara, Turkey
[2] Diskapi Yildirim Beyazit Training & Res Hosp, Dept Nephrol, Ankara, Turkey
关键词
Cataract surgery; chronic kidney disease; hemodialysis; intraocular lens power; ocular biometric parameters; CHRONIC-RENAL-FAILURE; OCULAR SURFACE; KIDNEY-DISEASE; PRESSURE; THICKNESS; CATARACT; CORNEAL; EYE;
D O I
10.3109/0886022X.2015.1128235
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background To evaluate changes in ocular biometric parameters after hemodialysis (HD) in patients with end-stage renal disease (ESRD). Methods Forty eyes of 40 patients undergoing HD were included in this cross-sectional study. Keratometry (K) readings, white-to-white (WTW) distance, central corneal thickness (CCT), anterior chamber depth (ACD), pupil diameter, lens thickness (LT), axial length (AL), and intraocular lens (IOL) power calculation were measured with Lenstar LS 900 (Haag Streit AG, Koeniz, Switzerland) before and after hemodialysis. Intraocular pressure (IOP) was measured with a non-contact tonometer (Tonopachy NT-530P, Nidek Co., LTD, Tokyo, Japan). Main outcomes were changes in biometric parameters after HD. Reliability of the measurements (intraclass correlation coefficients (ICCs)) and the effect size (Cohen's d) were also calculated. Results Mean difference in AL before and after HD was -0.041 +/- 0.022mm with ICCs>0.90 (p<0.001 and Cohen's d = 0.06). Pupil diameter was also significantly different before (4.28 +/- 0.81 mm) and after (4.44 +/- 0.79 mm) HD with ICCs>0.90 (p = 0.041 and Cohen's d = 0.20). Hemodialysis had no significant effect on K readings, WTW distance, CCT, ACD, LT, or IOP. Conclusion Axial length and pupil diameter increase after HD with small effect size, while HD does not significantly affect IOL power calculations.
引用
收藏
页码:209 / 213
页数:5
相关论文
共 50 条
  • [21] Intraoperative Aberrometry and Intraocular Lens Power Calculation
    Galvis, Virgilio
    Tello, Alejandro
    Sacoto, Jose I.
    JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (02) : 138 - 138
  • [22] Sources of error in intraocular lens power calculation
    Norrby, Sverker
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (03): : 368 - 376
  • [23] Intraocular lens power calculation in short eyes
    Gavin, E. A.
    Hammond, C. J.
    EYE, 2008, 22 (07) : 935 - 938
  • [24] Intraocular lens power calculation for the equine eye
    Meister, Ulrike
    Gorig, Christiane
    Murphy, Christopher J.
    Haan, Hubertus
    Ohnesorge, Bernhard
    Boeve, Michael H.
    BMC VETERINARY RESEARCH, 2018, 14
  • [25] Intraocular Lens Power Calculation: A Challenging Case
    Rosa, Nicola
    De Bernardo, Maddalena
    Iaccarino, Stefania
    Cennamo, Michela
    OPTOMETRY AND VISION SCIENCE, 2014, 91 (02) : E29 - E31
  • [26] Intraocular lens power calculation in short eyes
    E A Gavin
    C J Hammond
    Eye, 2008, 22 : 935 - 938
  • [27] INTRAOCULAR-LENS POWER CALCULATION - REPLY
    SANDERS, DR
    RETZLAFF, JA
    KRAFF, MC
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (04): : 454 - 456
  • [28] SIGNIFICANCE OF INTRAOCULAR-LENS POWER CALCULATION
    SINGH, M
    DAHALAN, A
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1987, 71 (11) : 850 - 853
  • [29] Intraocular lens power calculation for the equine eye
    Ulrike Meister
    Christiane Görig
    Christopher J. Murphy
    Hubertus Haan
    Bernhard Ohnesorge
    Michael H. Boevé
    BMC Veterinary Research, 14
  • [30] Intraoperative refraction for intraocular lens power calculation
    Biancardi, Ana Luiza
    Walsh, Aileen
    Crema, Armando Stefano
    REVISTA BRASILEIRA DE OFTALMOLOGIA, 2011, 70 (02) : 118 - 121