Effect of hemodialysis on intraocular lens power calculation

被引:5
|
作者
Caliskan, Sinan [1 ]
Celikay, Osman [1 ]
Bicer, Tolga [1 ]
Ayli, Mehmet Deniz [2 ]
Gurdal, Canan [1 ]
机构
[1] Diskapi Yildirim Beyazit Training & Res Hosp, Dept Ophthalmol, Ankara, Turkey
[2] Diskapi Yildirim Beyazit Training & Res Hosp, Dept Nephrol, Ankara, Turkey
关键词
Cataract surgery; chronic kidney disease; hemodialysis; intraocular lens power; ocular biometric parameters; CHRONIC-RENAL-FAILURE; OCULAR SURFACE; KIDNEY-DISEASE; PRESSURE; THICKNESS; CATARACT; CORNEAL; EYE;
D O I
10.3109/0886022X.2015.1128235
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background To evaluate changes in ocular biometric parameters after hemodialysis (HD) in patients with end-stage renal disease (ESRD). Methods Forty eyes of 40 patients undergoing HD were included in this cross-sectional study. Keratometry (K) readings, white-to-white (WTW) distance, central corneal thickness (CCT), anterior chamber depth (ACD), pupil diameter, lens thickness (LT), axial length (AL), and intraocular lens (IOL) power calculation were measured with Lenstar LS 900 (Haag Streit AG, Koeniz, Switzerland) before and after hemodialysis. Intraocular pressure (IOP) was measured with a non-contact tonometer (Tonopachy NT-530P, Nidek Co., LTD, Tokyo, Japan). Main outcomes were changes in biometric parameters after HD. Reliability of the measurements (intraclass correlation coefficients (ICCs)) and the effect size (Cohen's d) were also calculated. Results Mean difference in AL before and after HD was -0.041 +/- 0.022mm with ICCs>0.90 (p<0.001 and Cohen's d = 0.06). Pupil diameter was also significantly different before (4.28 +/- 0.81 mm) and after (4.44 +/- 0.79 mm) HD with ICCs>0.90 (p = 0.041 and Cohen's d = 0.20). Hemodialysis had no significant effect on K readings, WTW distance, CCT, ACD, LT, or IOP. Conclusion Axial length and pupil diameter increase after HD with small effect size, while HD does not significantly affect IOL power calculations.
引用
收藏
页码:209 / 213
页数:5
相关论文
共 50 条
  • [1] Intraocular lens power calculation
    Olsen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (12): : 2176 - 2177
  • [2] Pterygium size and effect on intraocular lens power calculation
    Koc, Mustafa
    Uzel, Mehmet Murat
    Aydemir, Emre
    Yavrum, Fuat
    Kosekahya, Pinar
    Yilmazbas, Pelin
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (11): : 1620 - 1625
  • [3] The Effect of Testing Distance on Intraocular Lens Power Calculation
    Simpson, Michael J.
    Charman, W. Neil
    JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (11) : 726 - 726
  • [4] Intraocular lens power calculation for lens exchange
    Kora, Y
    Shimizu, K
    Yoshida, M
    Inatomi, M
    Ozawa, T
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (04): : 543 - 548
  • [5] INTRAOCULAR-LENS POWER CALCULATION
    HOPEROSS, M
    MOONEY, D
    EYE, 1988, 2 : 367 - 369
  • [6] Intraocular lens power calculation software
    Kuchenbecker, J
    Behrens-Baumann, W
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (05): : 735 - 736
  • [7] Intraocular lens power calculation in children
    Eibschitz-Tsimhoni, Maya
    Archer, Steven M.
    Del Monte, Monte A.
    SURVEY OF OPHTHALMOLOGY, 2007, 52 (05) : 474 - 482
  • [8] CALCULATION OF INTRAOCULAR-LENS POWER
    SUNDERRAJ, P
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (03): : 387 - 388
  • [9] Intraocular lens power calculation REPLY
    Jin, Haiying
    Rabsilber, Tanja T.
    Ehmer, Angela
    Borkenstein, Andreas F.
    Limberger, Il-Joo
    Guo, Haike
    Auffarth, Gerd U.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (12): : 2177 - 2178
  • [10] Intraocular lens power calculation for microphthalmos
    Inatomi, M
    Ishii, K
    Koide, R
    Kora, Y
    Ozawa, T
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (08): : 1208 - 1212