Quality of vision after AMO array multifocal intraocular lens implantation

被引:99
|
作者
Sen, HN [1 ]
Sarikkola, AU [1 ]
Uusitalo, RJ [1 ]
Laatikainen, L [1 ]
机构
[1] Univ Helsinki, Hosp Eye, Helsinki 00029, Finland
来源
关键词
D O I
10.1016/j.jcrs.2004.04.049
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate safety and efficacy of Array(R) SA40N multifocal intraocular lens (IOL) (AMO) implantation in cataract surgery. Setting: Helsinki University Eye Hospital, Helsinki, Finland. Methods: In this prospective randomized comparative trial, 80 patients scheduled for cataract surgery were selected based on preoperative counseling and randomized to have multifocal or monofocal IOL implantation. Fifty-three eyes of 35 patients received a multifocal IOL and 67 eyes of 40 patients, a monofocal IOL. The incidence of complications and visual outcome in the multifocal and monofocal IOL groups were compared. Quality of vision was measured by comparing the severity of visual symptoms (glare, halos, and cataract symptoms score), changes in functional impairment measured by a 7-item visual function test (VF-7), changes in global measures of vision (trouble and satisfaction with vision), and range of accommodation and contrast sensitivity. Results: Intraoperative and postoperative complications and adverse events were few and required no further surgical intervention. Both distance and near visual acuities were significantly better in the multifocal group than in the monofocal group; the difference was most prominent in distance corrected near acuity (P<.001). Thirty-five eyes (67.3%) in the multifocal group and 10 eyes (14.9%) in the monofocal group achieved a distance corrected near acuity of J6 (20/40) or better; 30 eyes (56.6%) and 19 eyes (28.4%), respectively, achieved a best corrected distance acuity of 20/20 or better. Glare symptoms decreased postoperatively in both groups but were slightly more common in the multifocal group. In contrast, halos were significantly more common at 1 month in the multifocal group (P<.001). Contrast sensitivity values were slightly lower with multifocal IOLs at almost all spatial frequencies, but the difference was not significant. The change in the quality of life postoperatively, measured with the VF-7, was significant and identical in both groups. Conclusions: Pseudophakic eyes with multifocal IOLs had better distance and near acuity and range of accommodation than eyes with a monofocal IOL. Slightly lower contrast sensitivity and increased perception of halos by subjects with the multifocal IOL appear to be an acceptable compromise to enhanced near and distance vision.
引用
收藏
页码:2483 / 2493
页数:11
相关论文
共 50 条
  • [41] Effect of postoperative refractive error on visual acuity and patient satisfaction after implantation of the Array multifocal intraocular lens
    Lee, ES
    Lee, SY
    Jeong, SY
    Moon, YS
    Chin, HS
    Cho, SJ
    Oh, JH
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (10): : 1960 - 1965
  • [42] Analysis of visual quality after multifocal intraocular lens implantation in post-LASIK cataract patients
    Bai, Gali
    Li, Xinge
    Zhang, Songhao
    Wang, Qiman
    Liu, Guodan
    HELIYON, 2023, 9 (05)
  • [43] Visual acuity, contrast sensitivity, and quality of life after bilateral implantation of multifocal diffractive intraocular lens
    Queiroz, Marjorie F. N.
    Ferreira, Felipe Q. T.
    Shimoda, Gilberto
    Padovani, Carlos Roberto
    Lottelli, Antonio C.
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2023, 86 (04) : 301 - 307
  • [44] Optical quality evaluation and vision simulation of a binocular diffractive multifocal intraocular lens system vs. a conventional diffractive multifocal intraocular lens
    Naujokaitis, Tadas
    Labuz, Grzegorz
    Auffarth, Gerd U.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [45] SPECTACLE INDEPENDENCE AND VISION-RELATED QUALITY OF LIFE IN CATARACT SURGERY PATIENTS FOLLOWING IMPLANTATION OF A MULTIFOCAL INTRAOCULAR LENS
    Samiian, A.
    Carones, F.
    VALUE IN HEALTH, 2013, 16 (07) : A503 - A504
  • [46] Visual Outcomes, Quality of Vision, and Quality of Life of Diffractive Multifocal Intraocular Lens Implantation after Myopic Laser In Situ Keratomileusis: A Prospective, Observational Case Series
    Chang, John S. M.
    Ng, Jack C. M.
    Chan, Vincent K. C.
    Law, Antony K. P.
    JOURNAL OF OPHTHALMOLOGY, 2017, 2017
  • [47] Visual Outcomes and Quality of Vision After Bilateral Implantation of a Hydrophobic Acrylic Trifocal Intraocular Lens
    Newsom, T. Hunter
    Szabo, Brian
    Unsell, Kayla
    Newsom, Chase
    Ayers, Brooke
    Hall, Brad
    CLINICAL OPHTHALMOLOGY, 2025, 19 : 227 - 234
  • [48] Quality of vision following multifocal intraocular lens insertion: A multicenter study.
    Brunette, I
    Laflamme, M
    Hamam, H
    Simonet, P
    Parent, M
    Fontaine, N
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S488 - S488
  • [49] AMO array multifocal lens versus monofocal correction in cataract surgery
    Brydon, KW
    Tokarewicz, AC
    Nichols, BD
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (01): : 96 - 100
  • [50] Managing dissatisfaction after multifocal intraocular lens implantation through lens exchange using monofocal or alternative multifocal IOLs
    Al-Shymali, Olena
    Canto, Mario
    Alio del Barrio, Jorge L.
    McAlinden, Colm
    Yebana, Pilar
    Alio, Jorge L.
    ACTA OPHTHALMOLOGICA, 2024, 102 (07) : e1040 - e1049