A multisyringe flow injection system coupled with a gas diffusion cell for ammonium determination

被引:10
|
作者
Klimundová, J
Forteza, R
Cerdá, V
机构
[1] Univ Balearic Isl, Dept Chem, E-07071 Palma de Mallorca, Spain
[2] Charles Univ, Fac Pharm Hradec Kralove, Prague, Czech Republic
关键词
multisyringe flow injection analysis (MSFIA); ammonium; gas diffusion;
D O I
10.1080/10306731021000048582
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multisyringe flow injection system for ammonium determination based on the coupling of a gas-diffusion separation cell has been developed. By using a multisyringe burette equipped with additional three-way solenoid valves, the system allows the use of different reagents or samples with further propelling into a gas-diffusion unit. Two possibilities were tested to increase the sensitivity and repetitivity: flow delay during the diffusion of the ammonia formed and use of successive flow reversals. The proposed MSFIA system is compared with the FIA and SIA techniques based on the same principle and has been validated applying the method to the determination of ammonium in environmental samples.
引用
收藏
页码:233 / 246
页数:14
相关论文
共 50 条
  • [21] Sensitive kinetic-catalytic spectrophotometric method for cobalt determination using a chip coupled to a multisyringe flow injection analysis system
    Zohra Abouhiat, Fatima
    Henriquez, Camelia
    El Yousfi, Farida
    Cerda, Victor
    TALANTA, 2017, 166 : 405 - 411
  • [22] Optical fibre reflectance sensor for the determination and speciation analysis of iron in fresh and seawater samples coupled to a multisyringe flow injection system
    Pons, C
    Forteza, R
    Cerdà, V
    ANALYTICA CHIMICA ACTA, 2005, 528 (02) : 197 - 203
  • [23] Optical fiber reflectance sensor coupled to a multisyringe flow injection system for preconcentration and determination of 1-naphthylamine in water samples
    Mar, J. L. Guzman
    Lopez Martinez, L.
    Lopez de Alba, P. L.
    Castrejon Duran, J. E.
    Cerda Martin, V.
    ANALYTICA CHIMICA ACTA, 2006, 573 : 406 - 412
  • [24] Multisyringe flow injection spectrophotometric determination of uranium in water samples
    Jorge L. Guzmán Mar
    Leticia López Martínez
    Pedro L. López de Alba
    Nancy Ornelas Soto
    Víctor Cerdà Martín
    Journal of Radioanalytical and Nuclear Chemistry, 2009, 281 : 433 - 439
  • [25] DETERMINATION OF AMMONIUM ION IN A FLOW-INJECTION SYSTEM WITH A GAS-DIFFUSION MEMBRANE - SELECTION OF OPTIMAL CONDITIONS FOR THE PH INDICATOR
    NAKATA, R
    KAWAMURA, T
    SAKASHITA, H
    NITTA, A
    ANALYTICA CHIMICA ACTA, 1988, 208 (1-2) : 81 - 90
  • [26] Titanium determination by multisyringe flow injection analysis system and a liquid waveguide capillary cell in solid and liquid environmental samples
    Sanchez-Quiles, David
    Tovar-Sanchez, Antonio
    Horstkotte, Burkhard
    MARINE POLLUTION BULLETIN, 2013, 76 (1-2) : 89 - 94
  • [27] Flow injection gas-diffusion amperometric determination of trace amounts of ammonium ions with a cupric hexacyanoferrate
    Department of Chemistry, Liaocheng Teachers College, Liaocheng, Shandong, China
    TALANTA, 7 (1049-1054):
  • [28] Flow injection gas-diffusion amperometric determination of trace amounts of ammonium ions with a cupric hexacyanoferrate
    Liu, RM
    Sun, BT
    Liu, DJ
    Sun, AL
    TALANTA, 1996, 43 (07) : 1049 - 1054
  • [29] Gas diffusion flow injection determination of thiomersal in vaccines
    Fredj, Asma
    Okbi, Hafidha
    Adhoum, Nafaa
    Monser, Lotfi
    TALANTA, 2012, 91 : 47 - 51
  • [30] Determination of mercury by multisyringe flow injection system with cold-vapor atomic absorption spectrometry
    Leal, L. O.
    Elsholz, O.
    Forteza, R.
    Cerda, V.
    ANALYTICA CHIMICA ACTA, 2006, 573 : 399 - 405