Comparison of anterior chamber depth measurement methods in phakic and pseudophakic eyes

被引:60
|
作者
Kriechbaum, K
Findl, O
Kiss, B
Sacu, S
Petternel, V
Drexler, W
机构
[1] Univ Vienna, Inst Med Phys, A-1090 Vienna, Austria
[2] Univ Vienna, Dept Ophthalmol, A-1090 Vienna, Austria
来源
关键词
D O I
10.1016/S0886-3350(02)01822-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare anterior chamber depth (ACD) measurements in phakic and pseudophakic eyes using a slit-beam photographic technique (IOLMaster, Carl Zeiss Meditec AG) with those obtained with the laboratory prototype version of partial coherence interferometry (PCI) and with conventional applanation ultrasound in phakic eyes. Setting: Department of Ophthalmology, Vienna General Hospital, Vienna University, Vienna, Austria. Methods: Thirty-three ACDs of 28 patients with age-related cataract were measured preoperatively with a slit-beam photographic technique (IOLMaster) and the prototype version of PCI. In 24 eyes, the ACID was also assessed with applanation ultrasound. In addition, 34 ACDs of 18 pseudophakic patients in a different study population were examined postoperatively with the IOLMaster and PCI Results: The median ACD in the phakic eyes was 3.06 mm (range 1.93 to 3.90 mm) with the IOLMaster, 3.09 mm with PCI (range 1.49 to 4.06 mm), and 2.87 mm (range 2.18 to 3.33 mm) with applanation ultrasound. The precision was 0.005 mm for PCI and 0.015 mm for IOLMaster measurement. The median difference between the IOLMaster and PCI ACD biometry was 0.01 mm +/- 0.14 (SD) (range -0.44 to 0.17 mm) (P = .71). In pseudophakic eyes, the 2 methods showed a median difference of -0.22 mm (range -0.45 to 1.99 mm) (P > .1) and did not correlate (r = 0.21; P > .2). Conclusions: In phakic eyes, the difference between IOLMaster and PCI measurements was small and not statistically significant. In pseudophakic eyes, the difference was larger and the methods did not correlate. (C) 2003 ASCRS and ESCRS.
引用
收藏
页码:89 / 94
页数:6
相关论文
共 50 条
  • [31] ANTERIOR-CHAMBER DEPTH IN EYES WITH PSEUDOEXFOLIATION
    BARTHOLOMEW, RS
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1980, 64 (05) : 322 - 323
  • [32] Endothelial changes in phakic eyes after anterior chamber lens implantation
    Eifrig, DE
    Peiffer, RL
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (10): : 1392 - 1392
  • [33] THE REMOVAL OF SILICONE OIL FROM THE ANTERIOR-CHAMBER IN PHAKIC EYES
    KIRKBY, GR
    GREGOR, ZJ
    ARCHIVES OF OPHTHALMOLOGY, 1987, 105 (11) : 1592 - 1592
  • [34] Comparison of Dysphotopsia Effects in Phakic and Pseudophakic Eyes using Rostock Glare Perimeter
    Meikies, D.
    van der Mooren, M.
    Guthoff, R. F.
    Stachs, O.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2013, 230 (12) : 1213 - 1219
  • [35] The Comparison of Scotopic and Mesopic Contrast Sensitivity with Glare Between Pseudophakic and Phakic Eyes
    Muftuoglu, Orkun
    Karel, Fatih
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2008, 38 (02): : 110 - 115
  • [36] Comparison of Anterior Chamber Depth of Normal and Keratoconus Eyes Using Scheimpflug Photography
    Edmonds, Charles R.
    Wung, Shu-Fen
    Pemberton, Bart
    Surrett, Steven
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2009, 35 (03): : 120 - 122
  • [37] Assessment of midperipheral anterior chamber depth in patient with posterior chamber phakic intraocular lens
    Tenen, Abigail
    Roberts, Kate
    Sack, Julian
    Hodge, Chris
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (10): : 1611 - 1614
  • [38] Comparison of amplitude of apparent accommodation in pseudophakic eyes with that of normal accommodation in phakic eyes in various age groups
    Hayashi, K
    Hayashi, H
    EYE, 2006, 20 (03) : 290 - 296
  • [39] Comparison of amplitude of apparent accommodation in pseudophakic eyes with that of normal accommodation in phakic eyes in various age groups
    K Hayashi
    H Hayashi
    Eye, 2006, 20 : 290 - 296
  • [40] Comparability of anterior chamber depth measurements with partial coherence interferometry and optical low-coherence reflectometry in pseudophakic eyes
    Luft, Nikolaus
    Hirnschall, Nino
    Farrokhi, Sanaz
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (08): : 1678 - 1684