Integration of post-combustion capture and storage into a pulverized coal-fired power plant

被引:117
|
作者
Sanpasertparnich, Teerawat [1 ]
Idem, Raphael [1 ]
Bolea, Irene [2 ]
deMontigny, David [1 ]
Tontiwachwuthikul, Paitoon [1 ]
机构
[1] Univ Regina, Int Test Ctr CO2 Capture, Regina, SK S4S 0A2, Canada
[2] Univ Zaragoza, Ctr Politecn Super, CIRCE, Zaragoza 50018, Spain
关键词
CO2; capture; compression; CCS; Coal-fired power plant; Energy penalty; Partial capture; CO2; CAPTURE; AMINE; SIMULATION; CYCLE;
D O I
10.1016/j.ijggc.2009.12.005
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Post-combustion CO2 capture and storage (CCS) presents a promising strategy to capture, compress, transport and store CO2 from a high volume-low pressure flue gas stream emitted from a fossil fuel-fired power plant. This work undertakes the simulation of CO2 capture and compression integration into an 800 MW supercritical coal-fired power plant using chemical process simulators. The focus is not only on the simulation of full load of flue gas stream into the CO2 capture and compression, but also, on the impact of a partial load. The result reveals that the energy penalty of a low capture efficiency, for example, at 50% capture efficiency with 10% flue gas load is higher than for 90% flue gas load at the equivalent capture efficiency by about 440 kWh(e)/tonne CO2. The study also addresses the effect of CO2 capture performance by different coal ranks. It is found that lignite pulverized coal (PC)-fired power plant has a higher energy requirement than subbituminous and bituminous PC-fired power plants by 40.1 and 98.6 MWe, respectively. In addition to the investigation of energy requirement, other significant parameters including energy penalty, plant efficiency, amine flow rate and extracted steam flow rate, are also presented. The study reveals that operating at partial load, for example at half load with 90% CO2 capture efficiency, as compared with full load, reduces the energy penalty, plant efficiency drop, amine flow rate and extracted steam flow rate by 9.9%, 24.4%, 50.0% and 49.9%, respectively. In addition, the effect of steam extracted from different locations from a series of steam turbine with the objective to achieve the lowest possible energy penalty is evaluated. The simulation shows that a low extracted steam pressure from a series of steam turbines, for example at 300 kPa, minimizes the energy penalty by up to 25.3%. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:499 / 510
页数:12
相关论文
共 50 条
  • [21] CO2 post-combustion capture in coal-fired power plants integrated with solar systems
    Carapellucci, R.
    Giordano, L.
    Vaccarelli, M.
    33RD UIT (ITALIAN UNION OF THERMO-FLUID DYNAMICS) HEAT TRANSFER CONFERENCE, 2015, 655
  • [22] Membrane properties required for post-combustion CO2 capture at coal-fired power plants
    Roussanaly, Simon
    Anantharaman, Rahul
    Lindqvist, Karl
    Zhai, Haibo
    Rubin, Edward
    JOURNAL OF MEMBRANE SCIENCE, 2016, 511 : 250 - 264
  • [23] Dynamic operation of post-combustion CO2 capture in Australian coal-fired power plants
    Bui, Mai
    Gunawan, Indra
    Verheyen, T. Vincent
    Meuleman, Erik
    Feron, Paul
    12TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, GHGT-12, 2014, 63 : 1368 - 1375
  • [24] Intelligent scheduling and flexible operation for the commercial-scale coal-fired power plant integrated with post-combustion carbon capture
    Liao, Peizhi
    Wu, Xiao
    Wang, Meihong
    IFAC PAPERSONLINE, 2022, 55 (09): : 553 - 558
  • [25] Performance analysis of a 500MWe coal-fired power plant with a post-combustion CO2 capture process
    Lee, Ji Hyun
    Kwak, No Sang
    Lee, In-Young
    Jang, Kyung-Ryoung
    Shim, Jae-Goo
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2013, 227 (03) : 149 - 156
  • [26] Performance and economic analysis of commercial-scale coal-fired power plant with post-combustion CO2 capture
    Lee, Ji Hyun
    Kwak, No Sang
    Lee, In Young
    Jang, Kyung Ryoung
    Lee, Dong Woog
    Jang, Se Gyu
    Kim, Byung Kook
    Shim, Jae-Goo
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2015, 32 (05) : 800 - 807
  • [27] China baseline coal-fired power plant with post-combustion CO2 capture: 1. Definitions and performance
    Cui, Qian
    Lu, Haoren
    Li, Chufu
    Singh, Surinder
    Ba, Liming
    Zhao, Xinglei
    Ku, Anthony Y.
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2018, 78 : 37 - 47
  • [28] Performance and Economic Analysis of 500 MWe Coal-Fired Power Plant with Post-Combustion CO2 Capture Process
    Lee, Ji Hyun
    Kim, Jun-Han
    Lee, In Young
    Jang, Kyung Ryoung
    Shim, Jae-Goo
    KOREAN CHEMICAL ENGINEERING RESEARCH, 2011, 49 (02): : 244 - 249
  • [29] Performance and economic analysis of commercial-scale coal-fired power plant with post-combustion CO2 capture
    Ji Hyun Lee
    No Sang Kwak
    In Young Lee
    Kyung Ryoung Jang
    Dong Woog Lee
    Se Gyu Jang
    Byung Kook Kim
    Jae-Goo Shim
    Korean Journal of Chemical Engineering, 2015, 32 : 800 - 807
  • [30] Integrating mid-temperature solar heat and post-combustion CO2-capture in a coal-fired power plant
    Zhao, Yawen
    Hong, Hui
    Zhang, Xiaosong
    Jin, Hongguang
    SOLAR ENERGY, 2012, 86 (11) : 3196 - 3204