Wall Shear Stress Assessment of the False Lumen in Acute Type B Aortic Dissection Visualized by 4-Dimensional Flow Magnetic Resonance Imaging: An Ex-Vivo Study

被引:8
|
作者
Veger, Hugo T. C. [1 ]
Pasveer, Erik H. [1 ]
Westenberg, Jos J. M. [2 ]
Wever, Jan J. [1 ]
van Eps, Randolph G. Statius [1 ]
机构
[1] Haga Teaching Hosp, Dept Vasc Surg, Els Borst Eilerspl 275, NL-2545 AA The Hague, Netherlands
[2] Leiden Univ, Dept Radiol, Med Ctr, Leiden, Netherlands
关键词
aortic dissection; type B; four-dimensional flow magnetic resonance imaging; ex-vivo; THORACIC AORTA; TEAR SIZE; MANAGEMENT; QUANTIFICATION; PRESSURE; PORCINE; MOTION; MODEL;
D O I
10.1177/15385744211017117
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Four-dimensional flow magnetic resonance imaging (4D flow MRI) can accurately visualize and quantify flow and provide hemodynamic information such as wall shear stress (WSS). This imaging technique can be used to obtain more insight in the hemodynamic changes during cardiac cycle in the true and false lumen of uncomplicated acute Type B Aortic Dissection (TBAD). Gaining more insight of these forces in the false lumen in uncomplicated TBAD during optimal medical treatment, might result in prediction of adverse outcomes. Methods: A porcine aorta dissection model with an artificial dissection was positioned in a validated ex-vivo circulatory system with physiological pulsatile flow. 4D flow MR images with 3 set heartrates (HR; 60 bpm, 80 bpm and 100 bpm) were acquired. False lumen volume per cycle (FLV), mean and peak systolic WSS were determined from 4D flow MRI data. For validation, the experiment was repeated with a second porcine aorta dissection model. Results: During both experiments an increase in FLV (initial experiment: Delta FLV = 2.05 ml, p < 0.001, repeated experiment: Delta FLV = 1.08 ml, p = 0.005) and peak WSS (initial experiment: Delta WSS = 1.2 Pa, p = 0.004, repeated experiment: Delta WSS = 1.79 Pa, p = 0.016) was observed when HR increased from 60 to 80 bpm. Raising the HR from 80 to 100 bpm, no significant increase in FLV (p = 0.073, p = 0.139) was seen during both experiments. The false lumen mean WSS increased significant during initial (2.71 to 3.85 Pa; p = 0.013) and non-significant during repeated experiment (3.22 to 4.00 Pa; p = 0.320). Conclusion: 4D flow MRI provides insight into hemodynamic dimensions including WSS. Our ex-vivo experiments showed that an increase in HR from 60 to 80 bpm resulted in a significant increase of FLV and WSS of the false lumen. We suggest that strict heart rate control is of major importance to reduce the mean and peak WSS in uncomplicated acute TBAD. Because of the limitations of an ex-vivo study, 4D flow MRI will have to be performed in clinical setting to determine whether this imaging model would be of value to predict the course of uncomplicated TBAD.
引用
收藏
页码:696 / 701
页数:6
相关论文
共 30 条
  • [21] Partial Aortic Valve Leaflet Fusion Is Related to Deleterious Alteration of Proximal Aorta Hemodynamics A 4-Dimensional Flow Magnetic Resonance Imaging Study
    Guala, Andrea
    Rodriguez-Palomares, Jose
    Galian-Gay, Laura
    Teixido-Tura, Gisela
    Johnson, Kevin M.
    Wieben, Oliver
    Sao Aviles, Augusto
    Evangelista, Arturo
    CIRCULATION, 2019, 139 (23) : 2707 - 2709
  • [22] Influence of Pulse Wave Velocity on Atherosclerosis and Blood Flow Reversal in the Aorta A 4-Dimensional Flow Magnetic Resonance Imaging Study in Acute Stroke Patients and Matched Controls
    Wehrum, Thomas
    Dragonu, Iulius
    Strecker, Christoph
    Hennemuth, Anja
    Hennig, Juergen
    Reinhard, Thomas
    Harloff, Andreas
    JOURNAL OF THORACIC IMAGING, 2022, 37 (01) : 42 - 48
  • [23] Four-dimensional flow magnetic resonance imaging visualizes significant changes in flow pattern and wall shear stress in the ascending aorta after transcatheter aortic valve implantation in a patient with severe aortic stenosis
    Komoriyama, Hirokazu
    Tsuneta, Satonori
    Oyama-Manabe, Noriko
    Kamiya, Kiwamu
    Nagai, Toshiyuki
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2020, 21 (01) : 21 - 21
  • [24] Accurate noninvasive quantitation of blood flow, cross-sectional lumen vessel area and wall shear stress by three-dimensional paraboloid modeling of magnetic resonance imaging velocity data
    Oyre, S
    Ringgaard, S
    Kozerke, S
    Paaske, WP
    Erlandsen, M
    Boesiger, P
    Pedersen, EM
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (01) : 128 - 134
  • [25] Low and Oscillatory Wall Shear Stress Is Not Related to Aortic Dilation in Patients With Bicuspid Aortic Valve A Time-Resolved 3-Dimensional Phase-Contrast Magnetic Resonance Imaging Study
    Dux-Santoy, Lydia
    Guala, Andrea
    Sotelo, Julio
    Uribe, Sergio
    Teixido-Tura, Gisela
    Ruiz-Munoz, Aroa
    Hurtado, Daniel E.
    Valente, Filipa
    Galian-Gay, Laura
    Gutierrez, Laura
    Gonzalez-Alujas, Teresa
    Johnson, Kevin M.
    Wieben, Oliver
    Ferreira, Ignacio
    Evangelista, Arturo
    Rodriguez-Palomares, Jose F.
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2020, 40 (01) : E10 - E20
  • [26] Wall shear stress and relative residence time as potential risk factors for abdominal aortic aneurysms in males: a 4D flow cardiovascular magnetic resonance case–control study
    Chiara Trenti
    Magnus Ziegler
    Niclas Bjarnegård
    Tino Ebbers
    Marcus Lindenberger
    Petter Dyverfeldt
    Journal of Cardiovascular Magnetic Resonance, 24
  • [27] Wall shear stress and relative residence time as potential risk factors for abdominal aortic aneurysms in males: a 4D flow cardiovascular magnetic resonance case-control study
    Trenti, Chiara
    Ziegler, Magnus
    Bjarnegard, Niclas
    Ebbers, Tino
    Lindenberger, Marcus
    Dyverfeldt, Petter
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2022, 24 (01)
  • [28] Letter by Shar et al Regarding Article, "Low and Oscillatory Wall Shear Stress Is Not Related to Aortic Dilation in Patients With Bicuspid Aortic Valve: A Time-Resolved 3-Dimensional Phase-Contrast Magnetic Resonance Imaging Study"
    Shar, Jason A.
    Liu, Janet
    Atkins, Samantha K.
    Sucosky, Philippe
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2020, 40 (04) : E114 - E115
  • [29] Low and Oscillatory Wall Shear Stress Is Not Related to Aortic Dilation in Patients With Bicuspid Aortic Valve: A Time-Resolved 3-Dimensional Phase-Contrast Magnetic Resonance Imaging Study (vol 40, pg e10, 2020)
    Dux-Santoy
    Ferreira-Gonzalez, Ignacio
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2021, 41 (02) : E142 - E142
  • [30] Response by Dux-Santoy et al to Letter Regarding Article, "Low and Oscillatory Wall Shear Stress Is Not Related to Aortic Dilation in Patients With Bicuspid Aortic Valve: A Time-Resolved 3-Dimensional Phase-Contrast Magnetic Resonance Imaging Study"
    Dux-Santoy, Lydia
    Guala, Andrea
    Sotelo, Julio
    Uribe, Sergio
    Teixido-Tura, Gisela
    Evangelista, Arturo
    Rodriguez-Palomares, Jose F.
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2020, 40 (04) : E116 - E117